Cisco Blog » The Platform

2016年3月1日星期二

Cisco Notification Alert -Nexus 6000 Series Switch-01-Mar-2016 17:49 GMT

 

 

 

 

 

 

 


Security Advisories & Responses - Nexus 6000 Series Switches

Title:
Cisco Nexus 9000 Series ACI Mode Switch ICMP Record Route Vulnerability
Description:

A vulnerability in the ICMP implementation in the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch could allow an unauthenticated, remote attacker to cause the switch to reload, resulting in a denial of service (DoS) condition.

The vulnerability is due to improper handling of an ICMP packet with the IPv4 Type 7 option for record route. An attacker could exploit this vulnerability by sending an ICMP packet with the record route option to an interface on the affected switch. An exploit could allow the attacker to cause a DoS condition because the switch will reload each time the ICMP packet is received.

Cisco has released software updates that address this vulnerability. A workaround that addresses this vulnerability is available.

This advisory is available at the following link: http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160203-n9knci

Date:
03-FEB-2016
Title:
Cisco Application Policy Infrastructure Controller Access Control Vulnerability
Description:

A vulnerability in the role-based access control (RBAC) of the Cisco Application Policy Infrastructure Controller (APIC) could allow an authenticated remote user to make configuration changes outside of their configured access privileges.  

The vulnerability is due to eligibility logic in the RBAC processing code. An authenticated user could exploit this vulnerability by sending specially crafted representational state transfer (REST) requests to the APIC. An exploit could allow the authenticated user to make configuration changes to the APIC beyond the configured privilege for their role.

Cisco has released software updates that address this vulnerability.

This advisory is available at the following link: http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20160203-apic

Date:
03-FEB-2016

Find additional information in Cisco Security Advisories & Responses

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
NX-OS System Software
Release Version:
7.3(0)N1(1)
Alert Type:
New File
File Name:
n6000-uk9.7.3.0.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.3(0)N1(1) System Image

File Release Date:
18-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
NX-OS System Software
Release Version:
7.0(8)N1(1)
Alert Type:
New File
File Name:
n6000-uk9.7.0.8.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) System Image

File Release Date:
26-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
NX-OS System Software
Alert Type:
 
Suggested:
  

Find additional information in Software Downloads index.

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
Data Center Network Manager
Release Version:
7.2(3)
Alert Type:
New File
File Name:
dcnm-installer-x64-windows.7.2.3.exe
File Description:

DCNM 7.2.3 Installer for Windows (64-bit)

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-installer-x64-linux.7.2.3.bin
File Description:

DCNM 7.2.3 Installer for Linux (64-bit)

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-san-client.7.2.3.zip
File Description:

DCNM 7.2.3 San Client Package

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-va-templates.7.2.3.zip
File Description:

DCNM 7.2.3 Virtual Appliance templates for VMWare (.ovf) and KVM (domain XMLs) environments

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-va.7.2.3.iso
File Description:

DCNM 7.2.3 ISO Virtual Appliance for VMWare, KVM and Bare-metal servers

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-va.7.2.3.ova
File Description:

DCNM 7.2.3 Open Virtual Appliance for VMWare

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-silent-installer-properties.7.2.3.zip
File Description:

DCNM 7.2.3 Silent Installer Property Files

File Release Date:
17-FEB-2016
Find additional information in Software Downloads index.

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
NX-OS Kick Start
Release Version:
7.0(8)N1(1)
Alert Type:
New File
File Name:
n6000_poap_script.7.0.8.N1.1.tcl
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) TCL Reference script for PowerOn Auto Provisioning (POAP)

File Release Date:
26-FEB-2016
Alert Type:
New File
File Name:
n6000-uk9-kickstart.7.0.8.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) Kick Start Image

File Release Date:
26-FEB-2016
Alert Type:
New File
File Name:
n6000_poap_script.7.0.8.N1.1.py
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) Python Reference script for PowerOn Auto Provisioning (POAP)

File Release Date:
26-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6004 Switch
Software Type:
NX-OS Kick Start
Release Version:
7.3(0)N1(1)
Alert Type:
New File
File Name:
oac.7.3.0.N1.1.ova
File Description:

Cisco Nexus 6000/5600 Series Switches 7.2(0)N1(1) Open Virtualization Archive for the Cisco Systems Open Agent Container

File Release Date:
18-FEB-2016
Find additional information in Software Downloads index.

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
NX-OS System Software
Release Version:
7.0(8)N1(1)
Alert Type:
New File
File Name:
n6000-uk9.7.0.8.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) System Image

File Release Date:
26-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
NX-OS System Software
Release Version:
7.3(0)N1(1)
Alert Type:
New File
File Name:
n6000-uk9.7.3.0.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.3(0)N1(1) System Image

File Release Date:
18-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
NX-OS System Software
Alert Type:
 
Suggested:
  

Find additional information in Software Downloads index.

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
Data Center Network Manager
Release Version:
7.2(3)
Alert Type:
New File
File Name:
dcnm-va-templates.7.2.3.zip
File Description:

DCNM 7.2.3 Virtual Appliance templates for VMWare (.ovf) and KVM (domain XMLs) environments

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-va.7.2.3.iso
File Description:

DCNM 7.2.3 ISO Virtual Appliance for VMWare, KVM and Bare-metal servers

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-silent-installer-properties.7.2.3.zip
File Description:

DCNM 7.2.3 Silent Installer Property Files

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-va.7.2.3.ova
File Description:

DCNM 7.2.3 Open Virtual Appliance for VMWare

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-installer-x64-linux.7.2.3.bin
File Description:

DCNM 7.2.3 Installer for Linux (64-bit)

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-san-client.7.2.3.zip
File Description:

DCNM 7.2.3 San Client Package

File Release Date:
17-FEB-2016
Alert Type:
New File
File Name:
dcnm-installer-x64-windows.7.2.3.exe
File Description:

DCNM 7.2.3 Installer for Windows (64-bit)

File Release Date:
17-FEB-2016
Find additional information in Software Downloads index.

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
NX-OS Kick Start
Release Version:
7.3(0)N1(1)
Alert Type:
New File
File Name:
oac.7.3.0.N1.1.ova
File Description:

Cisco Nexus 6000/5600 Series Switches 7.2(0)N1(1) Open Virtualization Archive for the Cisco Systems Open Agent Container

File Release Date:
18-FEB-2016

Software Updates for Nexus 6000 Series Switches

Product Name:
Nexus 6001 Switch
Software Type:
NX-OS Kick Start
Release Version:
7.0(8)N1(1)
Alert Type:
New File
File Name:
n6000_poap_script.7.0.8.N1.1.py
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) Python Reference script for PowerOn Auto Provisioning (POAP)

File Release Date:
26-FEB-2016
Alert Type:
New File
File Name:
n6000_poap_script.7.0.8.N1.1.tcl
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) TCL Reference script for PowerOn Auto Provisioning (POAP)

File Release Date:
26-FEB-2016
Alert Type:
New File
File Name:
n6000-uk9-kickstart.7.0.8.N1.1.bin
File Description:

Cisco Nexus 6000/5600 Series Switches 7.0(8)N1(1) Kick Start Image

File Release Date:
26-FEB-2016
Find additional information in Software Downloads index.

Known Bugs - Nexus 6000 Series Switches

Alert Type:
Updated *
Bug Id:
CSCuw51800
Title:
unable to delete param-list from config file
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
When using auto-config, the param-list of a profile are not removed when a profile is un-applied.

Conditions:
This happens after "copy r s" and reload reload with param-list / applied configs present in startup config.

Workaround:
Use no param-list xyz cross-check command to force remove the param-list if it is not actually being used.

Further Problem Description:

Last Modified:
19-FEB-2016
Known Affected Releases:
7.3(0)N1(0.150)
Known Fixed Releases: *
7.0(3)I3(0.276), 7.0(3)I3(1), 7.0(3)IAB3(0), 7.0(3)IAB3(0.100), 7.1(3)ZN(0.131), 7.1(4)N1(0.696), 7.1(4)N1(1), 7.2(2)N1(0.379), 7.2(2)N1(1), 7.2(2)ZN(0.62)
Alert Type:
Updated *
Bug Id:
CSCuy08128
Title:
Cut through Threshold change on Tiburon FEX's on 40gb NIF's
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
Under rare conditions a Nexus 2300 series fabric extender might corrupt packets. This is due to an incorrect buffer setting in software on the FEX. Once this issue is hit the FEX will need to be reloaded to recover.

Conditions:

Workaround:
Reload the FEX.

Further Problem Description:

Last Modified:
26-FEB-2016
Known Affected Releases:
7.1(3)N1(1)
Known Fixed Releases: *
7.0(7)ZN(0.284), 7.0(7)ZN(0.285), 7.1(3)N1(2.7), 7.1(3)N1(3), 7.1(3)ZD(0.95), 7.1(3)ZN(0.200), 7.1(3)ZN(0.201), 7.1(4)N1(0.743), 7.1(4)N1(0.744), 7.1(4)N1(1)
Alert Type:
Updated *
Bug Id:
CSCuy14813
Title:
After changing fcoe pinning in AA FEX, HIF ports need flap
Status:
Open
Severity:
2 Severe
Description: *

Symptom:
Logins are flushed out automatically and port goes into to Error disabled state

Conditions:
fcoe pinning is removed

fex
no fcoe

Workaround:
flap host interfaces (sh/no sh) to achieve correct state of ports and for login clean state.

Further Problem Description:

Last Modified:
20-FEB-2016
Known Affected Releases:
7.3(0)N1(0.283)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw66815
Title:
Nexus 5k/6k may reload with "fex hap reset" when FEX is not supported.
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
Device reloads with "fex hap reset" after "show fex" or "show fex # transceiver".

Conditions:
FEX is not supported in used NX-OS version.

Workaround:
Upgrade to NX-OS which supports this FEX.

Further Problem Description:
N/A

Last Modified:
19-FEB-2016
Known Affected Releases:
7.0(7)N1(1)
Known Fixed Releases: *
7.0(3)I3(0.272), 7.0(3)I3(1), 7.0(3)IAB3(0), 7.0(3)IAB3(0.100), 7.3(0)IZN(0.7), 7.3(0)N1(0.169), 7.3(0)N1(1), 7.3(0)ZN(0.157)
Alert Type:
Updated *
Bug Id:
CSCuw93085
Title:
After shutting down an i/f , it takes long time to get to shut state
Status:
Open
Severity:
2 Severe
Description:

Symptom:The reason is the port-channel is in adminCfgChange state for that much time.



Conditions:In vPC setup scale setup, It is seen that on shutdown of port-channel interface, there is a traffic drop for around 8-10 seconds. After it is completely down , the routes are removed from the adjacent routers... after which the traffic converges.
Workaround:None

Last Modified:
01-FEB-2016
Known Affected Releases: *
7.3(0)N1(0.177), 7.3(0)N1(0.208)
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCux32809
Title:
kk218:ISSU to upg fails in 5672 due totimeoutof hitless linecard upgrade
Status:
Open
Severity:
2 Severe
Description:

Symptom:
The issue is ISSU fails during the fex upgrade . ISSU fails showing the errror description and the error id and also where the issue is seen (here issue is with fex upgrade).

Conditions:
This issue is seen during ISSU in N6k having its host and target in fex and connected to brocade switch (peer switch is brocade) and the topology is FCOE.

Workaround:
Trying issu for multiple times is a workaround to perform a successful issu.

Further Problem Description:

Last Modified:
12-FEB-2016
Known Affected Releases:
7.3(0)N1(0.218)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCui84039
Title:
ascii-cfg core and n6k reload observed no feature-set fabricpath
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
ascii-cfg process crash when doing "no feature-set fabricpath"

Nexus# sh core
Module Instance Process-name PID Date(Year-Month-Day Time)
------ -------- --------------- -------- -------------------------
1 1 ascii-cfg 3675 2011-03-27 00:00:46

Nexus(config)# no feature-set fabricpath
Feature-set Operation may take up to 30 minutes depending on the size of configuration.

[362482.443853] Shutdown Ports..
[362482.479243] writing reset reason 16, ascii-cfg hap reset

Broadcast message from root (console) (Fri MSending all processes the TERM signal...
Sending all processes the KILL signal...
Unmounting filesystems...

Conditions:
Issue command:
Nexus(config)# no feature-set fabricpath

Workaround:
N/A

Further Problem Description:

Last Modified:
11-FEB-2016
Known Affected Releases:
6.0(2)N2(2), 6.0(2)N3(0.195)
Known Fixed Releases: *
5.2(1)N1(10), 5.2(1)N1(9.179), 7.0(0)N1(0.501), 7.0(0)N1(1), 7.0(0)ZN(0.208)
Alert Type:
Updated *
Bug Id:
CSCuu62888
Title:
N5K/N6K ISIS Neighbor with network type p2p adjacency not coming up
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
On a nexus 5000/6000 series switch, ISIS Neighbor with network type p2p is not coming up with routers running IOS-XR

Conditions:
None

Workaround:
None

Further Problem Description:
None

Last Modified:
19-FEB-2016
Known Affected Releases:
7.1(1)N1(1)
Known Fixed Releases: *
7.1(3)ZN(0.163), 7.1(4)N1(0.717), 7.1(4)N1(1), 7.3(0)BZN(0.47), 7.3(0)N1(1), 7.3(0)ZN(0.103)
Alert Type:
Updated *
Bug Id:
CSCux49563
Title:
msg format correction in fwm
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
msg format correction in fwm component.

Conditions:
Some syslog msgs format strings were not properly converted

Workaround:
none.

Further Problem Description:

Last Modified:
19-FEB-2016
Known Affected Releases:
7.3(0)N1(0.218)
Known Fixed Releases: *
7.3(0)N1(0.236), 7.3(0)N1(1), 7.3(0)ZN(0.213)
Alert Type:
Updated *
Bug Id:
CSCun90417
Title:
platform/storage/common/scripts/initsys/init-system-satnuova add to z7_0
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Sunnyside fex initsys script only get affected

Conditions:

Workaround:

Further Problem Description:

Last Modified:
13-FEB-2016
Known Affected Releases:
7.1(0)ZN(0.99)
Known Fixed Releases: *
7.0(0)BZ(0.46), 7.0(0)HSK(0.317), 7.0(0)KM(0.97), 7.0(1)ZD(0.158), 7.0(1)ZN(0.234), 7.0(3)N1(0.8), 7.0(3)N1(1), 7.1(0)D1(0.171), 7.1(0)FC(0.2), 7.1(0)NF(0.28)
Alert Type:
New
Bug Id:
CSCuw74228
Title:
peer-link inconsistency and peer keep alive fail when instantiating net
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
When instantiating/autoconfiguring networks on a EVPN programmable fabric setup , one sees the following messages on VPC leaf.
This message can also be seen when the networks are removed


%$ VDC-1 %$ %STP-2-VPC_PEER_LINK_INCONSIST_BLOCK: vPC peer-link de
ed Bridge Assurance Inconsistency blocking Po10 VLAN: 875.
2001 Dec 5 12:48:04 IP-FAB1-VPC1 %$ VDC-1 %$ %STP-2-VPC_PEER_LINK_INCONSIST_BLOCK: vPC peer-link deed BPDU receive timeout blocking Po10 VLAN: 46,881.

Conditions:

Workaround:
None

Further Problem Description:

Last Modified:
12-FEB-2016
Known Affected Releases:
7.3(0)N1(0.158)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv35326
Title:
N6k :: ICMPv6 related to neighbor discovery punted to the CPU
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
In Nexus5K/6K ICMPv6 packets related to neighbor discovery are punted to the CPU even if there is no SVI configured in vlan where packets are present.

Conditions:
Nx-OS version 7.0(0)N1(1) and newer - still to be confirmed

Workaround:
If this is causing drops in copp-system-class-arp, ARP policer can be increased.

Further Problem Description:

Last Modified:
10-FEB-2016
Known Affected Releases:
7.1(1)N1(1)
Known Fixed Releases: *
7.1(3)N1(0.659), 7.1(3)N1(1), 7.1(3)ZN(0.67), 7.2(2)N1(0.389), 7.2(2)N1(1), 7.2(2)ZN(0.71)
Alert Type:
New
Bug Id:
CSCuv99658
Title:
VPC peer link is not coming up after peer-link flap
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
VPC peer-link down.VPC peer link is not coming up after peer-link flap (reason:vPC peer is not reachable over cfs).

Conditions:
Its a timing issue and happens very very rarely. Mostly after first peer-link flap post reload.

Workaround:
Shut and no shut on the peer-link ie flapping the vpc peer-link will solve the issue.

Further Problem Description:

Last Modified:
09-FEB-2016
Known Affected Releases:
7.3(0)N1(0.104)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCus37334
Title:
N56k: global FCF mac as src fcns fames for vfc's with bind mac-address
Status:
Other
Severity:
3 Moderate
Description: *

Symptom:
- N56k sends a name server PLOGI_ACC using vsan global FCF mac instead of interface MAC. ethanalyzer can be used to capture the mac address used.
- host's affected will not have access to their storage.
- host's affected will not have fcns "fc4-types", "symbolic-port-name" and "symbolic-node-name" registered with the name server.

------------------------
VSAN:10 FCID:0xd30060
------------------------
port-wwn (vendor) :50:01:99:93:ed:2a:10:0c
[A-D-bc1atrabl09-hba1]
node-wwn :50:01:99:93:ed:2a:10:0d
class :3
node-ip-addr :0.0.0.0
ipa :00 00 00 00 1e 00 01 30
fc4-types:fc4_features : ---->
symbolic-port-name : ---->
symbolic-node-name : ---->
port-type :N
port-ip-addr :0.0.0.0
fabric-port-wwn :21:30:8c:60:4f:25:81:7f
hard-addr :0x000000
permanent-port-wwn (vendor) :50:01:99:93:ed:2a:10:0c
connected interface :vfc305
switch name (IP address) :RF_NEXUS1_SR1 (10.200.99.211)

- the following errors are shown under

"`show platform software fcoe_mgr event-history errors`"

356) Event:E_DEBUG, length:80, at 971774 usecs after Thu Dec 18 18:49:06 2014
[102] fcoe_mgr_fill_get_fcoe_info(2822): vfc301 eth_ifindex is invalid, skipping

Conditions:
all of the following must apply for the issue to be a hit on this bug.

- Nexus 5600 or 6000 only "N55k is not affected".
- software code 7.x.
- vfc's are configured to using "bind mac-address":

interface vfc301
bind mac-address 0019.993E.D302
switchport trunk allowed vsan 10
switchport description FCoE-to-Blade
no shutdown

Workaround:
configure the following:

- remove the vfc interfaces with bind mac-address.
- use one vfc interface that is bind to the physical interface.
- enable NPIV on the switch.

feature npiv
interface vfc 1
bind interface port-channel 1
switchport trunk allowed vsan 10
switchport description FCoE-to-Blade
no shutdown

with this setup, instead of using multiple vfc interfaces each one that is bound to a MAC. we will use on interface, and all the host's will login through that one vfc which is allowed through NPIV.

Further Problem Description:

Last Modified:
03-FEB-2016
Known Affected Releases:
7.0(5)N1(1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv91507
Title:
Migrating Fex from N7K to N6K/N5K may result in the FEX failing to boot
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
A FEX which is attached to an N7K running 6.2(12) or 7.2(0)D1(1) may fail to boot when moved to a Nexus 6K or Nexus 5K:

08/21/2015 00:51:59.593386: Module register received
08/21/2015 00:51:59.594388: Image Version Mismatch
08/21/2015 00:51:59.595438: Registration response sent
08/21/2015 00:51:59.595794: Requesting satellite to download image
08/21/2015 00:53:52.981356: Image preload failed.
08/21/2015 00:54:00.132452: Deleting route to FEX
08/21/2015 00:54:00.141675: Module disconnected
08/21/2015 00:54:00.143718: Module Offline
08/21/2015 00:54:00.152157: Deleting route to FEX
08/21/2015 00:54:00.159062: Module disconnected
08/21/2015 00:54:00.161167: Offlining Module

Conditions:
Issue has been observed on 2248TP-E FEX conencted to F3 line card on N7K.

Workaround:
On 5K/6K running 7.2, the issue can be corrected by unplugging and plugging the cable back in at the FEX uplink.

Further Problem Description:
Migrating Fex from N7K to N6K/N5K may result in the FEX failing to boot

Last Modified:
29-FEB-2016
Known Affected Releases:
6.2(12), 7.2(0)D1(1)
Known Fixed Releases: *
7.3(0)IZN(0.13), 7.3(0)N1(0.208), 7.3(0)N1(1), 7.3(0)ZN(0.188), 8.3(0)CV(0.337)
Alert Type:
Updated *
Bug Id:
CSCuy45682
Title:
Comunity starting with '/!#' is not shown on running config
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
SNMP was not supporting few characters in the older releases

Conditions:
Using a community string that starts with '/!#' , community is not being shown on the running config, however it can be polled.

Workaround:
Use #show snmp community command

Further Problem Description:

Last Modified:
25-FEB-2016
Known Affected Releases: *
7.0(2)N1(1), 7.2(1)N1(1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux85363
Title:
N5600/6K : IGMP GSQ are not sent out in response to IGMP leaves
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Upon receiving IGMP leaves for certain groups, IGMP group specific queries are generated by the CPU but the group specific queries are never sent out on the switch towards the host.

Conditions:
- Nexus 5600/6000
- this is only seen when multiple IGMP snooping entries are present for those groups on that vlan
- Issue is not seen if only one snooping entry is present

Workaround:
None

Further Problem Description:

Last Modified:
25-FEB-2016
Known Affected Releases:
8.3(0)CV(0.272)
Known Fixed Releases: *
7.1(3)ZN(0.201), 7.1(4)N1(0.744), 7.1(4)N1(1)
Alert Type:
Updated *
Bug Id:
CSCuq96902
Title:
N6K QSFP-40G-CSR4 shows up as "transceiver is not supported"
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
QSFP-40G-CSR4 transceivers do not come up after no shut, and show "transceiver is not supported" in show int eX/Y transceiver details

Conditions:

Workaround:
service unsupported-transceiver - will bring the transceiver up into a working state, but it will still show as an unsupported transceiver.

Reload the LEM with the following commands:
power off module
no power off module

Further Problem Description:

Last Modified:
24-FEB-2016
Known Affected Releases:
6.0(2)N2(2)
Known Fixed Releases: *
7.0(7)N1(0.66), 7.0(7)N1(1), 7.0(7)ZN(0.142), 7.1(1)N1(1)
Alert Type:
New
Bug Id:
CSCuy00762
Title:
SNMP dot3StatsDuplexStatus doesnt populate for mgmt0
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
SNMP OID dot3StatsDuplexStatus is not populating to show the duplex value of the interface mgmt0 on Nexus6000/Nexus5000.

Conditions:
When queried for OID dot3StatsDuplexStatus through SNMP for interface mgmt0.

Workaround:
Query duplex value for the interface mgmt0 through CLI 'show interface mgmt0'.

Further Problem Description:
NA

Last Modified:
24-FEB-2016
Known Affected Releases:
7.1(2)N1(1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCup74458
Title:
few seconds of packet loss on vpc secondary link bringup
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Few seconds of packet loss seen on VPC link bringup. Drops would correspond with PIF drop counter on fex uplink port

N6K-2(config-if)# show platform fwm info pif ethernet 1/7/1 | grep drop
Eth1/7/1 pd: tx stats: bytes 204948156412 frames 2328371667 discard 0 drop 0
Eth1/7/1 pd: rx stats: bytes 177822996614 frames 2388580485 discard 0 drop 1173850 <---HERE

Conditions:
VPC is being restored on a Nexus 5K/6K and traffic re-hashes to the newly brought up VPC. The delay is due to VLAN programming on the VPC trunk.

Workaround:
Reduce the number of VLANs on the VPC trunk by manually clearing not needed VLANs.

Further Problem Description:

Last Modified:
24-FEB-2016
Known Affected Releases:
6.0(2)N2(3), 7.0(2)N1(1)
Known Fixed Releases: *
6.0(2)N2(5.95), 6.0(2)N2(6), 7.0(1)ZN(0.710), 7.0(6)N1(0.214), 7.0(6)N1(1), 7.1(0)EVN(0.18), 7.1(0)N1(0.356), 7.1(0)N1(1), 7.1(0)ZN(0.432), 7.1(1)N1(1)
Alert Type:
Updated *
Bug Id:
CSCux35886
Title:
N5K/6K: No core saved for ipqosmgr process crash
Status:
Fixed
Severity:
4 Minor
Description:

Symptom:
In a Nexus 5K/6K, if ipqosmgr process restarts, no core file gets written

Conditions:
IPQOSMGR process undergoes a unexpected restart

Workaround:
None

Further Problem Description:

Last Modified:
12-FEB-2016
Known Affected Releases:
7.1(3)N1(1)
Known Fixed Releases: *
7.3(1)N1(0.29), 7.3(1)N1(1)
Alert Type:
Updated *
Bug Id:
CSCul00657
Title:
HW entry not programmed for remote host prefix due to some steps
Status:
Open
Severity:
6 Enhancement
Description:

Symptom:
The problem occurs when we change the VNI. You will see following syslogs when you hit this issue.

FWM-2-VLAN_VNI_MAPPING_INCORRECT: VLAN to VNI mapping is incorrect

Conditions:
The problem occurs when we change the VNI.

Workaround:
First Try shut/no-shut of VRF, if that doesn't works then Reload is the only option.

Further Problem Description:

Last Modified:
29-FEB-2016
Known Affected Releases:
6.0(2)N3(0.288), 7.1(0)N1(0.370), 7.2(0)N1(0.147), 7.2(1)N1(0.313)
Known Fixed Releases: *
7.3(0)IZN(0.7), 7.3(0)N1(0.189), 7.3(0)N1(1), 7.3(0)ZN(0.172), 8.3(0)CV(0.337)
Alert Type:
Updated *
Bug Id:
CSCuu66977
Title:
show tech enhancement
Status:
Fixed
Severity:
6 Enhancement
Description:

Symptom:
relevant info is not generated while running show tech command for l2 multicast on n6k platform.

Conditions:
while running show tech command for l2 multicast on n6k platform.

Workaround:
none.

Further Problem Description:

Last Modified:
09-FEB-2016
Known Affected Releases:
7.3(0)N1(0)
Known Fixed Releases: *
7.1(3)N1(0.622), 7.1(3)N1(1), 7.1(3)ZN(0.29), 7.2(2)N1(0.388), 7.2(2)N1(1), 7.2(2)ZN(0.70), 7.3(0)BZN(0.41), 7.3(0)N1(0.75), 7.3(0)N1(1), 7.3(0)ZN(0.73)
Alert Type:
Updated *
Bug Id:
CSCuv39838
Title:
CLI to dump all SGs in a system
Status:
Fixed
Severity:
6 Enhancement
Description:

Symptom:
None. This is an enhancement to introduce new CLI.

Conditions:
while running commands. show-tech.

Workaround:
none.

Further Problem Description:

Last Modified:
11-FEB-2016
Known Affected Releases:
7.3(0)N1(0)
Known Fixed Releases: *
7.1(3)N1(0.622), 7.1(3)N1(1), 7.1(3)ZN(0.29), 7.2(2)N1(0.390), 7.2(2)N1(1), 7.2(2)ZN(0.72), 7.3(0)N1(0.75), 7.3(0)N1(1), 7.3(0)ZN(0.73)
Alert Type:
Updated *
Bug Id:
CSCuu67165
Title:
pss runtime oifl not showing correct info
Status:
Fixed
Severity:
6 Enhancement
Description:

Symptom:
pss runtime oifl not showing correct info vi command "show platform fwm info pss runtime_oifl".

Conditions:
while running show command.

Workaround:
none.

Further Problem Description:

Last Modified:
19-FEB-2016
Known Affected Releases:
7.3(0)N1(0)
Known Fixed Releases: *
7.1(3)N1(0.622), 7.1(3)N1(1), 7.1(3)ZN(0.29), 7.2(2)N1(0.388), 7.2(2)N1(1), 7.2(2)ZN(0.70), 7.3(0)N1(1), 7.3(0)ZN(0.79)

Find additional information in Bug Search index.

 

2015 Cisco and/or its affiliates. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks

 

没有评论: