Cisco Blog » The Platform

2015年10月1日星期四

Cisco Notification Alert -Cisco Optical - Prime Optical-01-Oct-2015 16:50 GMT

 

 

 

 

 

 

 


End-of-Sale and End-of-Life Announcements - Prime Optical

Title:
End-of-Sale and End-of-Life Announcement for the Cisco Prime Optical 10.0
Description:

Cisco announces the end-of-sale and end-of-life dates for the Cisco Prime Optical 10.0. The last day to order the affected product(s) is March 10, 2016. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Table 1 describes the end-of-life milestones, definitions, and dates for the affected product(s). Table 2 lists the product part numbers affected by this announcement. For customers with active and paid service and support contracts, support will be available under the terms and conditions of customers' service contract. Click here for the French Version of this Bulletin.

Date:
11-SEP-2015

Find additional information in End-of-Sale and End-of-Life Products

Security Advisories & Responses - Prime Optical

Title:
OpenSSL Alternative Chains Certificate Forgery Vulnerability (July 2015) Affecting Cisco Products
Description:

On July 9, 2015, the OpenSSL Project released a security advisory detailing a vulnerability affecting applications that verify certificates, including SSL/Transport Layer Security (TLS)/Datagram Transport Layer Security (DTLS) clients and SSL/TLS/DTLS servers using client authentication.

Multiple Cisco products incorporate a version of the OpenSSL package affected by this vulnerability that could allow an unauthenticated, remote attacker to cause certain checks on untrusted certificates to be bypassed, enabling the attacker to forge "trusted" certificates that could be used to conduct man-in-the-middle attacks.

This advisory will be updated as additional information becomes available.

Cisco will release free software updates that address this vulnerability.

Workarounds that mitigate this vulnerability may be available.

This advisory is available at the following link:
http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20150710-openssl

Date:
16-SEP-2015
Title:
Multiple Vulnerabilities in OpenSSL (January 2015) Affecting Cisco Products
Description:

Multiple Cisco products incorporate a version of the OpenSSL package affected by one or more vulnerabilities that could allow an unauthenticated, remote attacker to cause a denial of service condition or perform a man-in-the-middle attack. On January 8, 2015, the OpenSSL Project released a security advisory detailing eight distinct vulnerabilities. The vulnerabilities are referenced in this document as follows:

  • CVE-2014-3571: OpenSSL DTLS Message Processing Denial of Service Vulnerability
  • CVE-2015-0206: OpenSSL dtls1_buffer_record Function DTLS Message Processing Denial of Service Vulnerability
  • CVE-2014-3569: OpenSSL no-ssl3 Option NULL Pointer Dereference Vulnerability
  • CVE-2014-3572: OpenSSL Elliptic Curve Cryptographic Downgrade Vulnerability
  • CVE-2015-0204: OpenSSL RSA Temporary Key Cryptographic Downgrade Vulnerability
  • CVE-2015-0205: OpenSSL Diffie-Hellman Certificate Validation Authentication Bypass Vulnerability
  • CVE-2014-8275: OpenSSL Certificate Fingerprint Validation Vulnerability
  • CVE-2014-3570: OpenSSL BN_sql Function Incorrect Mathematical Results Issue
Cisco will release software updates that address these vulnerabilities.

Workarounds that mitigate these vulnerabilities may be available.

This advisory is available at the following link:
http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20150310-ssl

Date:
22-SEP-2015

Find additional information in Cisco Security Advisories & Responses

Known Bugs - Prime Optical

Alert Type:
Updated *
Bug Id:
CSCuo56276
Title:
NE 9605 not alarmed on CTC network view cross launched from CPO
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
CTC network view displays no alarms on NE even if there are some active alarms.

Conditions:
The issue occurs when a NE in 9605 is connected to a NE in 9.8 software version cross launched from Prime Optical 9.8.

Workaround:
Launch CTC in standalone mode.

Further Problem Description:

Last Modified:
03-SEP-2015
Known Affected Releases:
9.8(0.3.2)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCui55677
Title:
getTP retrieve LR_ENCRYPTION even if WSE is in RGN-10G mode
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
The getTP API retrieves the encryption layer when WSE card is configured in RGN-10G mode.

Conditions:
This issue occurs when you configure the WSE for RGN-10G operating mode. After configuration, the encryption layer should not be available for RGN-10G, and must be available only for the encryption layer for TXP-10G operating mode.

Workaround:
None.


Last Modified:
16-SEP-2015
Known Affected Releases: *
10.0, 9.8(0.0.234)
Known Fixed Releases:
10.0(0.0.309)
Alert Type:
Updated *
Bug Id:
CSCti09988
Title:
The CreateTopologicalLink API returns an exception.
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
The CTM GateWay/CORBA CreateTopologicalLink API returns an exception when creating SONET/SDH manual links. However, the manual link is successfully created.

Conditions:
This problem occurs in the CTM GateWay/CORBA API interface.

Workaround:
Install the latest CTM R9.2 patch. For instructions, see the Release Notes for Cisco Transport Manager Release 9.2.

Last Modified:
16-SEP-2015
Known Affected Releases:
9.2(0.360)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuc68299
Title:
Unexpected error message opening circuit table on a group in Network Map
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom: error/warning message is displaying when open circuit table from network map for a group

Conditions:group should have a note of type routers(CRS)

Workaround:none

Further Problem Description: If a group contains routers(CRS), and since it belongs to sonet and sdh application will show a error message when opening a cirucit table. This is resoved

Last Modified:
16-SEP-2015
Known Affected Releases: *
9.6(0.128), 9.6(0.200.1), 9.6(3.1)
Known Fixed Releases:
9.6(3)
Alert Type:
Updated *
Bug Id:
CSCua75296
Title:
CPT: cannot set port parameters after NE re-synch
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
Cannot set Ethernet port parameters on CPT platform

Conditions:
the issue happens managing CPT devices after a NE re-syinc from the NE Explorer application

Workaround:
close and reopen the NE Explorer application

Further Problem Description:

Last Modified:
16-SEP-2015
Known Affected Releases: *
9.5(0.245), 9.6(0.1), 9.6(3.1), 9.8(0.0.239)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCup45370
Title:
Wrong control when creating DVR circuits
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
Selecting the destination end as the source on the diversity circuit, an error message appears "Request a diversity from a circuit with different source"

Conditions:
User creates DVR circuits

Workaround:
Use the other end

Further Problem Description:

Last Modified:
16-SEP-2015
Known Affected Releases:
10.0(0.0.309)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCtx08126
Title:
Exception thrown on getAllCurrentPMData on LR21 with LOP-v circuits
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
CorbaGW getAllCurrentPMData returns exception on Layer Rate 21 when LOP-v circuits are present.

Conditions:
LOP-v circuits (for example VC12-2v) going trough an STM card (for example STM4_4)

Workaround:
None

Last Modified:
16-SEP-2015
Known Affected Releases: *
9.2(0.472), 9.3(1), 9.5(1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCsq96596
Title:
If a GE_XP card has only one PPM, the SVLAN tab does not work correctly.
Status:
Fixed
Severity:
4 Minor
Description: *


Symptom: In the NE Explorer for a GE_XP card, the SVLAN tab does not work
correctly.

Conditions: This problem applies to a GE_XP card with only one PPM. It does
not apply to GE_XP cards that have at least two PPMs.

Workaround: Install the latest CTM R8.0 or R8.5 patch. For instructions, see
the Release Notes for Cisco Transport Manager Release 8.0 or 8.5.

Last Modified:
16-SEP-2015
Known Affected Releases:
8.5(0.1)
Known Fixed Releases:
8.0(0.907.3), 8.5(0.378.1)
Alert Type:
Updated *
Bug Id:
CSCua47343
Title:
NE default values are out of range for cervino cards.
Status: *
Terminated
Severity:
4 Minor
Description: *

Symptom:
Some NE Defaults are out of range. Due to this, the Apply action fails.

AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower
AR-XP.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower
AR-XP.opticalthresholds.client.oc3.cwdm.alarm.HighRxPower
AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.LowRxPower
AR-XP.opticalthresholds.client.oc3.cwdm.alarm.LowRxPower
AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.HighTxPower
AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.HighRxPower
AR-XP.opticalthresholds.client.oc3.cwdm.alarm.HighTxPower

These are null
10x10G-LC.opticalthresholds.SFP-PORT.10gfibrechannel
AR-MXP.opticalthresholds.trunk.4gfibrechannel.sm.
AR-XP.opticalthresholds.trunk.4gfibrechannel.sm.

Conditions:
Node with 9.6 version upgraded from previous release

Workaround:
none

Further Problem Description:

Last Modified:
14-SEP-2015
Known Affected Releases:
10.0(0.0.1), 10.0(2.0.1), 10.3(0.0.1), 9.6(0.1), 9.6(3.1), 9.8(0.0.1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCua76080
Title:
100G-LC-C, M-CFP-LC, 10x10G_LC cards - failure setting NE Default values
Status: *
Terminated
Severity:
4 Minor
Description:

Symptom:
From Cisco Prime Optical client GUI, restore default value of any parameter from NE Defaults tab pane (changed before from CTC) and push the Apply button.
=> The operation fails. The following error message is returned:

"Parameter AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower cannot be set. Verify that the value is in range. If it is not in range, choose a valid value from the range diplayed"

Conditions:
100G-LC-C, 10x10G_LC, CFP-LC cards plugged in or pre-provisioned into a Cisco ONS 15454 M6 node.

Workaround:
None

Further Problem Description:
The error message refers to a wrong parameter:

AR-MXP.opticalthresholds.client.oc3.cwdm.alarm.LowTxPower

instead of the modified one:

100G-LC-C.otn.fecthresholds.otu4.standard.1day.UncorrectableWords

Moreover, pushing the OK button to close the error message, the value changed does not restore to the original value and not even remains in bold character.
The Problem exists on all 100G_LC_C, 10x10G_LC, CFP_LC cards and all their parameters.

Last Modified:
14-SEP-2015
Known Affected Releases:
10.0(0.0.1), 10.0(2.0.1), 10.3(0.0.1), 9.6(0.93), 9.6(3.1), 9.8(0.0.1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCtx80567
Title:
AR-XP cards: Empty GFP counters shown for Real-Time video payloads PM.
Status:
Terminated
Severity:
5 Cosmetic
Description: *

Symptom:
Some counters on AR_XP/AR_MXP real-time payload Performance Monitoring have got N/A value.
Those counters are:

- gfpStatsRxCRCErrors
- gfpStatsRxSblkCRCErrors
for real SDI_3G_VIDEO payload provisioned, and:

- gfpStatsCHecRxMBitErrors
- gfpStatsCHecTxMBitErrors
for real ISC3_STP_1G payload provisioned,

Conditions:
Perform PM Query by Category operation on real AR_XP/AR_MXP cards having card mode configured and SDI_3G_VIDEO & ISC3_STP_1G payload provisioned.

Workaround:
None

Further Problem Description:
None

Last Modified:
11-SEP-2015
Known Affected Releases:
10.0(0.0.1), 10.0(2.0.1), 10.3(0.0.1), 9.5(0.159), 9.6(0.1), 9.6(3.1), 9.8(0.0.1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCtr53746
Title:
CorbaGW does not allow to create or get RMON thresholds
Status:
Open
Severity:
6 Enhancement
Description: *

Symptom: RMON threasholds cannot be created or retrieved from CorbaGW.

Conditions: CTM manages NEs equipped with C-series, E-series, G-series or any other card that supports RMON Thresholds.

Workaround: RMON Thresholds can only be created and viewd from CTM GUI.

Last Modified:
16-SEP-2015
Known Affected Releases:
9.2(0.435)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCue49103
Title:
Circuit types displayed should be filtered based on the NE type
Status:
Open
Severity:
6 Enhancement
Description: *

Symptom:
Circuit types displayed should be filtered based on the NE type.

Conditions:

Workaround:

Last Modified:
16-SEP-2015
Known Affected Releases:
9.6
Known Fixed Releases:

Find additional information in Bug Search index.

 

2013 Cisco and/or its affiliates. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks

 