Cisco Blog » The Platform

2016年7月3日星期日

Cisco Notification Alert -Prime - Cisco Prime Network-04-Jul-2016 05:39 GMT

 

 

 

 

 

 

 


Software Updates for Prime Network

Product Name:
Prime Network 4.2.3
Software Type:
Prime Network Patches
Release Version:
4.2.3.0.2
Alert Type:
New File
File Name:
Prime_Network4.2.3.0.2.zip
File Description:

Prime Network 4.2.3 Point Patch 2

File Release Date:
30-JUN-2016
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2
Software Type:
Prime Network VNE Drivers
Release Version:
4.2-DP1606
Alert Type:
New File
File Name:
PrimeNetwork-4.2-DP1606.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.2.0.1.7,4.2.0.1.6,4.2.0.1.5,4.2.0.1.4,4.2.0.1.3,4.2.0.1.2,4.2.0.1.1,4.2.0.1.0

File Release Date:
30-JUN-2016
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2
Software Type:
Prime Network Patches
Release Version:
4.2.0.1.7
Alert Type:
New File
File Name:
Prime_Network4.2.0.1.7.zip
File Description:

Prime Network 4.2 Service Patch 1 Point Patch 7

File Release Date:
09-JUN-2016
Find additional information in Software Downloads index.

Known Bugs - Prime Network

Alert Type:
New
Bug Id:
CSCuz93525
Title:
PN - DB framework - Oracle ConnectionPool and JDBC have blocking locks
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
AVM 11 threads can become blocked, critical code sections timeout and eventually cause a crash; leads to instability in AVM11, AVM25, AVM35, AVM44, AVM100, and XMP/NCCM

Conditions:
One common trigger is a thread running a long query, most often related to Tickets.

Workaround:
kill the affected query, and resolve anything that may be triggering the slowness in the query; or optimize the query

Further Problem Description:

Last Modified:
03-JUN-2016
Known Affected Releases:
4.3(0.999)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuy22568
Title:
CDPTest fails to match link endpoint between Nexus-5K VNEs
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
PN fails to discover Ethernet and physical links using CDP Test when link endpoint is located on Nexus-5K device. If link discovery can be accomplished only with CDP Test, the links will not be discovered.

Conditions:
At least one endpoint of the physical link originates on Nexus-5K device and CDP enabled.

Workaround:

Further Problem Description:

Last Modified:
14-JUN-2016
Known Affected Releases:
4.2(2.0)PP4, 4.2(3)
Known Fixed Releases: *
4.2(0.1)PP7, 4.2(2.0)PP6
Alert Type:
Updated *
Bug Id:
CSCuv76305
Title:
CCM: Edit Compliance audit job displays only 25 devices
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Device not found while editing already run compliance audit job.
It does not show all the devices when editing compliance audit job.
when selecting all the devices by clicking "select all" check box only 500 devices are selected on the right hand side.

Conditions:
running prime network lower than 4.2.2

Workaround:
instead of editing the job create a new one.

Further Problem Description:

Last Modified:
14-JUN-2016
Known Affected Releases:
4.2(1)
Known Fixed Releases: *
4.1(0.1)PP3, 4.2(0.1)PP7, 4.2(2)
Alert Type:
Updated *
Bug Id:
CSCuu60574
Title:
CCM IOS-XR Image distribution Job is not added in Job page
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Schedule a Image distribution job in Prime network and it is not shown in Image job page.

Conditions:
Primary Product: Prime Network CCM
Component: Prime Network CCM Issues
Version: 4.1(0)
Patch Level: 4.1.0.1.0

Device type : IOS-XR

Workaround:
None, this is fixed in Prime network 4.2.


Further Problem Description:
none

Last Modified:
14-JUN-2016
Known Affected Releases:
4.1(0.1)PP1
Known Fixed Releases: *
4.1(0.1)PP2, 4.2(0.1)PP7, 4.2(2.0)PP4, 4.2(3.0)PP1
Alert Type:
Updated *
Bug Id:
CSCuu93256
Title:
PN - NCCM - Command Manager Preview fails
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Unable to preview Command Manager script output prior to execution
Getting the following error:
Can't find resource for bundle java.util.PropertyResourceBundle, key Unable to fetch DP name

Conditions:
All Devices
All Commands (new + predefined)

Workaround:
None

Further Problem Description:

Last Modified:
14-JUN-2016
Known Affected Releases:
4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(1.0)PP1
Known Fixed Releases: *
4.1(0.1)PP4, 4.2(0.1)PP7
Alert Type:
Updated *
Bug Id:
CSCud00287
Title:
VCB GUI will not display all brands modules of third party device
Status:
Terminated
Severity:
3 Moderate
Description: *

Symptom:
1) Module groups of only a few third-party vendors are displayed in the 'Modules' tab
2) Module group info is empty for a few third-party vendors when viewing vne-driver details in 'Drivers' tab

Conditions:
Unknown. One possible condition could be the installation of 3.9 PP2 and/or PP3

Workaround:
The user will have to use CLI command to add support for new modules.

Further Problem Description:
The user will not be able to view existing module support or add support for new unsupported modules.

Last Modified:
14-JUN-2016
Known Affected Releases:
3.9(0)PP3, 4.2(0.1)PP4
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw42244
Title:
Sometimes VNE get to Unsynchronized state due Telnet Collector timeout
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Some VNEs are falling to Currently Unsynchronized state due to Telnet Track Reachability Command failure in Telnet Collector.

Conditions:
Very intensive use of Telnet collector.

Workaround:
There is no workaround for this issue.

Further Problem Description:

Last Modified:
14-JUN-2016
Known Affected Releases:
4.2(0.1)PP4
Known Fixed Releases: *
4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(0.1)PP7, 4.2(2.0)PP3, 4.2(2.0)PP6
Alert Type:
Updated *
Bug Id:
CSCuu81578
Title:
PN - NCCM - Config Archives - Version hyperlink does not show config
Status: *
Open
Severity:
3 Moderate
Description:



Symptom:
The archived config for ASR5k is not presented when clicking the hyperlink presented in the "Version" column of the Configuration Archive screen.
The user is presented with the following output instead: {"items":"max_e"}

Conditions:
None

Workaround:
Archived config is viewable from the Edit Option instead.

Further Problem Description:

Last Modified:
15-JUN-2016
Known Affected Releases:
4.2(1.0)PP1, 4.2(2.651)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv16808
Title:
ASR9K satellite IC links not appear in ASR9K 5.3.1
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
ASR9K satellite IC links not appear in ASR9K 5.3.1.
Tested in Satellite ring and cascasing topologies

Conditions:
1. Model ASR9K SW version 5.3.1 with satellite

Workaround:

Further Problem Description:

Last Modified:
23-JUN-2016
Known Affected Releases: *
4.2(0X)DP1505.0.622, 4.2(2)DP1511.0.742, 4.2(3)DP1605.0.871
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCva18254
Title:
P-FM:PN or PPM TCA alarm don't receive in FM via prime network
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
While Fault Management installed in different server than PC the Ticket alarm from prime network doesn't receive

Conditions:
Install PC in different server and also Install FM in different server.
Integrate PP,PPM and PN
while a new ticket receive in prime network those alarm should forward to FM->PC and then we see the alarms didn't receive under alarm browser.
in rder to see those alarm I have to run "fmctl resync" command from FM server

Workaround:
run "fmctl resync" and then all alarms will be update but the new alarms that will arrive willn't be update hence require again run "fmctl resync"

Further Problem Description:
PN is not forwarding any ticket updates to PC/FM.

Last Modified:
28-JUN-2016
Known Affected Releases: *
4.2(3.0)PP2
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCva27050
Title:
ASR9912 VNE fails to parse %PLATFORM syslog messages
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
During fan tray OIR tests it was noticed that ASR9912 VNE fails to parse %PLATFORM-INV, %PLATFORM-SHELFMGR and %PLATFORM-ENVMON syslog messages.

Conditions:
ASR9912 VNE, fan tray OIR

Workaround:
none

Further Problem Description:

Last Modified:
29-JUN-2016
Known Affected Releases:
4.2(2)DP1605.0.871
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv06547
Title:
Nexus7K do not show OSPF v2 neighborswhen OSPF v2 and v3 has the same id
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
Nexus7K do not show OSPF v2 neighbors when OSPF v2 and v3 has the same process id

Conditions:
1. Model Nexus7K that has OSPF v2 and v3 with the same process id
2. Open Nexus7K inventory
2. Go to OSPF v3 and see if it has neighbors

Workaround:
NA

Further Problem Description:

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2, 4.2(1), 4.2(2), 4.2(3)
Known Fixed Releases:
4.2(2.0)PP6
Alert Type:
New
Bug Id:
CSCux26688
Title:
Native flow:Distribute and Activate of pie files for future time fails
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Distribution and activation operation for future time fails.

Conditions:
Activation of future time fails

Workaround:
Perform Activation separately after distribution is completed.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2(2.0)PP3, 4.2(3)
Known Fixed Releases:
4.2(3)
Alert Type:
New
Bug Id:
CSCux00529
Title:
bosmanageplugin not loaded in avm 11 after redundant unit is configured
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
After configuring a redundant unit , the subsequent launching of GUI will be locked up after avm 11 restart.

Conditions:
PN 4.2.2
A reduendant unit is configured and avm 11 is restarted subsequently

Workaround:
N.A.

Further Problem Description:

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2(2.0)PP1, 4.2(2.0)PP2
Known Fixed Releases:
4.2(2.0)PP3, 4.2(3.0)PP1, 4.3(0.881)
Alert Type:
New
Bug Id:
CSCuz34856
Title:
PN - NCCM device family for Nexus 5k is shown as MDS9222i
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
NCCM device family for Nexus 5k is shown as MDS9222i

Conditions:
From NCCM, if the user is selecting device for Image Management, there is a combo-box that allsows for sorting all devices based on Device Family. The Nexus 5k devices are being categorized under a family type = MDS9222i.

MDS922i is for the Cisco ? MDS 9222i Multiservice Modular Switch.

Workaround:
None

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2(3)DP1603.0.821
Known Fixed Releases:
4.1, 4.2(3)
Alert Type:
New
Bug Id:
CSCux18621
Title:
Email notification not working for Import from devices.
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Import from devices does not trigger any mail for the Job completion.

Conditions:
For all devices the issue is seen.

Workaround:
Check the Job details in CCM Page.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2(2.0)PP3
Known Fixed Releases:
4.2(3)
Alert Type:
New
Bug Id:
CSCux75862
Title:
View button is enabled for Compliance-audit-mail job at All Jobs page
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
View button is enabled for Compliance-audit-mail job

Conditions:
1.Launch CCM application
2.Login as root User
3.Navigate to Compliance Audit-->Jobs
4.Select any Compliance-audit-mail job

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
30-JUN-2016
Known Affected Releases:
4.2(3.791)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCva00517
Title:
Nexus6001: Evil twin DC errors for Power Supply modules
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
While modeling Nexus 6001 devices it was noticed that VNE logs multiple error messages "evil twin DC" for Power Supply modules.

Conditions:
Modeling device Nexus 6001

Workaround:
None

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3
Known Fixed Releases: *
4.1, 4.2, 4.2(2), 4.2(3)
Alert Type:
Updated *
Bug Id:
CSCut88602
Title:
ppm reports url in PN is pointing the wrong machine in DR setup
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
ppm cross launch report is not working from Network Vision - pointing to the wrong GW

Conditions:
GEO HA (DR) setup, after switchover

Workaround:
change in site.xml to the correct url (correct hostname)

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.2(0)PP999, 4.2(1), 4.2(2), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCur60321
Title:
Got an error when changing the PN gateway IP Address
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
When changing the PN gateway IP address through the script $HOME/Main/scripts/change_gw_ip.pl.

Got the error--" Failed to start Prime Network System is already up"

Conditions:
When changing the PN gateway through scripts

Workaround:
Restart the primenetwork as prime user by using the command (networkctl restart).

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(1), 4.2(1.491), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux80765
Title:
rsync_monitor_db.cmd on primary GEO ha node interfer with upgrade
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
upgrade on GEO HA fails

Conditions:
the following cron job is running on the primary node:

0,10,20,30,40,50 * * * * if [ -f /export/home/pnetwork/.local_ana ]; then /var/adm/cisco/prime-network/scripts/ha/rsync/rsync_monitor_db.cmd > /dev/null 2>&1; fi

Workaround:
before upgrade, upgrade the following line in cron list on primary:

0,10,20,30,40,50 * * * * if [ -f /export/home/pnetwork/.local_ana ]; then /var/adm/cisco/prime-network/scripts/ha/rsync/rsync_monitor_db.cmd > /dev/null 2>&1; fi

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.0(0.1)PP2, 4.1, 4.2, 4.2(0.1)PP0, 4.2(1), 4.2(2), 4.2(3), 4.3, 4.3(0.999)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCut05115
Title:
EFP ->Reg& PBBbridge->vfi->pwThe vfi forms an incorrect link with d EFP.
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
When an EFP and VFI are connected to a bridge (Regular or PBB bridge ), the VFI and EFP form incorrect links with each other. On expanding the VFI, the EFP is again contained in it and again form a link with the VFI within it)

Conditions:
On dropping down a bridge with an EFP connected to it from Add to Map ->Bridge domains and an associated VFI from Add to Map-> VPLS, the VFI from a link with the EFP .

Workaround:
No workaround available

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(1), 4.2(1)DP0.0.561, 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuz52738
Title:
ASR1K , does not have QOS container
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
ASR 1k does not have QOS container

Conditions:
1) Model ASR 1k 10.56.25.155 .
2) Create QOS policy in any interface .
3) Check the QOS container in the Logical inventory .

Workaround:

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.1, 4.1(0.1)PP4, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuz72978
Title:
When Ethernet port is a member of LACP, the LldpTest fails discover link
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
PN fails discover physical links for some pairs of routers connected over LACP aggregation, although the LLDP inventory is present and correct.

Conditions:
LLDP neighbor table contains records where remote port ID is LACP aggregation.

Workaround:
none

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2), 4.2(2.0)PP6, 4.2(3), 4.3
Known Fixed Releases: *
4.2(0.1)PP7, 4.2(2), 4.2(3)
Alert Type:
Updated *
Bug Id:
CSCuy20029
Title:
Newly added syslogs and traps to ipcore via VCB are not parsed by 76xx
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
The newly added ipcore syslogs via VCB are not getting into the syslog instead it goes to standard (generic) syslog.

Conditions:
Added to ipcore syslogs (cisco-syslog-ipcore-parsing-rules)

Workaround:
Syslog:
======
runRegTool.sh -gs 127.0.0.1 add 0.0.0.0 site/cisco-6500-syslog-product-parsing-rules
success
runRegTool.sh -gs 127.0.0.1 set 0.0.0.0 site/cisco-6500-syslog-product-parsing-rules/default cisco-syslog-ipcore-parsing-rules

This will work for 76xx if we do not have 6500 modelled in the same setup.

Trap:
====
unRegTool.sh -gs 127.0.0.1 add 0.0.0.0 site/cisco-6500-trap-product-parsing-rules
success
runRegTool.sh -gs 127.0.0.1 set 0.0.0.0 site/cisco-6500-trap-product-parsing-rules/default cisco-trap-ipcore-parsing-rules

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2)DP1509.0.671, 4.2(2)DP1601.0.751, 4.2(3), 4.3
Known Fixed Releases: *
4.1DP1603, 4.2(1)DP1603, 4.2(2)DP1603, 4.2(3), 4.2DP1603
Alert Type:
Updated *
Bug Id:
CSCus71242
Title:
DLP file manament causes gateway CPU use nears 100 or proc collisions
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Symptoms:

Severe:
* Users can see many instances of scripts being active.
* many processes of command 'lsof'
* the DLP Output folder continues to grow

Mild:
* Event Vision fills with errors/warnings regarding failure to move files from the DLP Output folder
for example: Checksum compare is failing between /infobright_dlp/ifb_dlp_data/DLP_Output_Files and /infobright_backup/ifb_backup
* Event Vision warnings may not be very frequent maybe 4-5 times daily.

Conditions:
there are number of scripts being executed as root from the crontab. The scripts have no protections against long runs of the script. The lack of protection leads to severe CPU and filesystem troubles.

This bug is for /var/adm/cisco/infobright/move_dlp_files.sh ; however the scripts in the same folder should be checked if any protections need to be used for their executions

The severe symptoms occur because of a very large backlog which can be because of systems being down for a long time or connectivity issues to the active gateway.

Workaround:
to prevent server failure:

-fix missing ssh key issue for infobright scripts:
ssh-keygen -f /var/adm/cisco/infobright/.ssh/id_rsa -N ''
cat /var/adm/cisco/infobright/.ssh/id_rsa.pub >> ~/.ssh/authorized_keys

-send keys to all pn hosts, gatways and units:
cd /var/adm/cisco/infobright/.ssh/
scp -p * :/var/adm/cisco/infobright/.ssh

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0.342), 4.2, 4.2(0.522), 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuu43463
Title:
PW link between ASR902 to other device disappear with no alarm after car
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
PW link between ASR902 to other device disappear with no alarm after card out.

The link disappear because PW container disappear from VNE inventory.
and PW tunnel down trap from other side not correlate and not create any ticket

Conditions:
1. Model ASR902, and SAR9K
2. Card out ASR902 card

Workaround:

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.1, 4.1(0)PP1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuq71407
Title:
TP snapshot is not being updated
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
TP snapshot is not getting updated properly.

Conditions:
When VNE or AVM is stopped, relevant elements in the snapshot gets deleted. It is geeting getting deleted only after 2-3 minutes.
If the AVM/VNE is stopped and started immediately then the snapshot is not updated.
Elements are deleted from the snapshot only after 2-3 minutes and never added once again.

Workaround:
None

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0)PP999, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCva17377
Title:
Failure retrieve software version after initialization shuts down VNE
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
When SNMP connectivity is restored after VNE developed Device Unreachable and then lost again, the failure to get device software version shuts down VNE.

Conditions:
Unstable SNMP connectivity with the device

Workaround:
Restart VNE.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(3.0)PP2, 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux95534
Title:
LLDP neihbors details are not modeld in PN for ME1200
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
LLDP neighbors details are not modeled in PN.

Conditions:
1. Modeled the two ME1200 devices.
2. Physically connect it (Gig 1/3-3,1/4-4)
3. Configure the LLDP through CLI/Command scriptin vision GUI
4. get show LLDP neighbor response using soap UI.

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1(0X)DP1601.0.772, 4.2(0X)DP1601.0.772, 4.2(1)DP1601.0.772, 4.2(2), 4.2(2)DP1601.0.772, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuy38751
Title:
NCS:Redundancy state of RP's not shown in the VNE
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Redundancy state is updated for RP's.

Conditions:
When NCS has HA setup.

Workaround:
None.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2)DP1601.0.752, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCut06773
Title:
Subinterface&Pw of a regular bridge are incorrectly contained in EVC
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
The components (Sub interface or EFP) connected to a regular bridge with an association such as pseudowire or vfi are shown in EVC discovery as separate entities and does not represent the actual connection of the components ie EFP/Subinterface ->Regular bridge ->Association (vfi/pseudowire)
This is because Regular bridges with associations are not displayed in bridge domain discovery (Feature implementation ).Hence, the components such as EFP /L3-Sub-interface will be contained in the EVC discovery along with the association such as vfi or pseudo wire without the regular bridge connecting them and hence is misleading as it will display only the name of the regular bridge which actually joins both the component and the association

Conditions:
From Add to Map->EVC discovery an EVC of the association ie vfi or pseudowire of the regular bridge and the components such as EFP or L3-subinterface is formed without actually representing the exact network scenario as regular bridges will not be discovered as part of Bridge domain discovery

Workaround:
None

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(1), 4.2(1)DP0.0.552, 4.2(1)DP0.0.561, 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw34406
Title:
PN - NetworkVlanDiscoveryPlugin - Placeholder OID not found exception
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Network VLAN Discovery Logs are rolling over with constant notifications when Nexus7k device is modeled from lab. Also these notifcication excetions are being written to 35.out log as well causing them to fill up as well.

Notification is coming from the following: java.lang.IllegalArgumentException: Placeholder OID not found

Conditions:
None

Workaround:
None

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(0.1)PP5, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux59041
Title:
Link down on unreachable alarm has broken location and not clean
Status:
Open
Severity:
3 Moderate
Description:

Link down on unreachable alarm has broken location and not clean

Symptom:
Link down on unreachable alarm has broken location and not clean

Conditions:
1. Model ASR9K
2. Shutdown link

Workaround:
None

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.1, 4.2, 4.2(1), 4.2(2), 4.2(2.0)PP3, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuz56859
Title:
ArrayIndexOutOfBoundsException in DcOidMapping when Get fails with excep
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
VNE develops ArrayIndexOutOfBoundsException in DcOidMapping when Get fails to translate Oid to PropertyHolder with exception, beaks handling of exception.

Conditions:
Get fails to translate Oid to PropertyHolder with exception and Oid string representation does not contain string "ContextName". For example PortOid for unassigned interfaces in Nexus7K or any legacy VNE with no contexts.

Workaround:
none

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2), 4.2(2.0)PP6, 4.2(3), 4.3
Known Fixed Releases: *
4.2(0.1)PP7, 4.2(2), 4.2(3)
Alert Type:
Updated *
Bug Id:
CSCuy74775
Title:
CCM: Nexus 7k Config backup fails using SFTP except for default VDC
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Config backup fails for all VDC (except default VDC).

Conditions:
device : Nexus 7k.
Transfer protocol: SFTP.

Workaround:
Use other transfer protocols if management VRF is used.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2)DP1601.0.791, 4.2(3), 4.3
Known Fixed Releases: *
4.2(3)DP1605, 4.2DP1605
Alert Type:
Updated *
Bug Id:
CSCuh56824
Title:
Longer VNE Deletion time observed when 7K VM's vCenter deleted
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Deleting/stopping a large scale VCenter VNE takes a long time.
For example, if a VCenter with 5000 or 7000 VMs is stopped or deleted, it takes 10 to 15 min for 5000 VMs and 25 min to 40 min for 7000 VMs.

Conditions:
Happens only for large scale VCenter where it has 5000 VMs or more.

Workaround:
None.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.0(0.131), 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux56356
Title:
webstart CCM link converts dashboard page to CCM login page
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Webstart launch page (
http://:6080/ana/services/install/install/webstart.html) gets redirected to CCM login page.

Conditions:
On clicking CCM link in webstart page.

Workaround:
none.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2.0)PP3, 4.2(3), 4.3
Known Fixed Releases: *
4.2(0.1)PP6, 4.2(2.0)PP4, 4.2(3), 4.3
Alert Type:
Updated *
Bug Id:
CSCuo86912
Title:
EFD not split after link down.
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
EFD not split after link down and they stayed in one efd and no service alarm for efd split has been generated.

Conditions:
Steps to reproduce: :

We have the link: AGG1-6524ME-NY-rec#GigabitEthernet1/28 ----- GG-6500-NY-rec# GigabitEthernet3/9
in up state
And A & Z sides of the above link are in same efds
Then we're shutting down the link
Then we expected to see that A & Z sides of the above link are in different efds,
but they stayed in one efd and of course no service alarm for efd split has been generated.

in addition we have empty container in Ethernet Flow Domain

Workaround:
N/A

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0.322), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCus31118
Title:
Operation Report install script fails in Local HA config
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Install fails and or the cluster.conf becomes corrupted by poor processing of the file.

Conditions:
* Local HA setup, with mapper partitions.
* Cluster configured and could be re-written by system tools after initial install by PN.

Workaround:
None, script fix required.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0.342), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCux91431
Title:
SONET/POS properties are missing
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
SONET/POS properties are missing

Conditions:
Cisco ASR903 + SONET/POS/Controller specific port configuration

Workaround:
We can see the properties in the Mediator Debugger or by pressing F2 on the interface

Further Problem Description:
None

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1(0X)DP1601.0.772, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3, 4.3(0X)DP0.0.911
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuy39072
Title:
SNMP track reachability does not reset retry counter when device reload
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
SNMP track reachability command does not reset retry counter when device is reloaded. As a result the VNE creates Device Unreachable alarm prematurely.

Conditions:
Number of retries for SNMP track reachability command is changed to more than 1

Workaround:
There is no workaround for this issue.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2.0)PP4, 4.2(3), 4.3
Known Fixed Releases: *
4.1(0.1)PP4, 4.2(0.1)PP7, 4.2(2.0)PP6, 4.3(0.881)
Alert Type:
Updated *
Bug Id:
CSCuw40593
Title:
PN failed to discover MPLS link between ASR903 and ASR920
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Some of the MPLS links, especially those originated on ASR920 VNEs are missing in topology.

Conditions:
Configuration of MPLS network with ASR920.

Workaround:
There is no workaround for this issue

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.2, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.3
Known Fixed Releases: *
4.2, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.2(3.0)PP1, 4.3
Alert Type:
Updated *
Bug Id:
CSCuq17839
Title:
P-PN: Chassis disconnect for satellite is not developed with card down
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Satellite Chassis Disconnect service alarm ticket isn't generated.

Conditions:
On performing card down for the card that is connected to satellite.

Workaround:
None

Further Problem Description:
The card down should be performed after ASR9k with Satellite is fully modeled and the the link between two chassis is discovered.

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0)PP1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw28932
Title:
Oper Reports - temp folder is not cleaned clogging file system
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Operation Report temporary files clogging disk space and causes the AVM25 process to stall

Conditions:
* perform a backup / restore while file are present in the temp folder

Workaround:
manually clear temporary file folder while PN is down, or delete all files that are exceedingly old

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1(0.1)PP2, 4.2, 4.2(0.1)PP4, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuy28373
Title:
PN - major upgrade script error while updating perms
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
* error seen while running upgrade from PN 4.1:
Can't call method "perm" on an undefined value at ./upgrade.pl line 3242.
* upgrade exists with this error

Conditions:
* Upgrade from older major release to latest release: PN 4.2.2
* single gateway, no units

Workaround:
modify the script as described and rerun.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2), 4.2(2.999), 4.2(3), 4.2(3.832), 4.3
Known Fixed Releases: *
4.2(3)
Alert Type:
Updated *
Bug Id:
CSCun47761
Title:
EFP missing from on the pseudowire and EVC service view
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
Missing EFP in EVC view.
This issue does not happen consistently.

Conditions:
Deletion of EFP from Pseudowires and re-adding may be the cause.

Workaround:
None.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0.321), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCup02954
Title:
SFP pluggable status is not refreshing while performing SFP in/out.
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
SFP pluggable status is not refreshing while performing SFP OIR.

Conditions:
Perform SFP OIR.

Workaround:
Moving the cursor location updates the SFP attributes.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.0, 4.0(0.1)PP4, 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuy20868
Title:
ASR1K to use new 64bit MIB parameters of CISCO-ENHANCED-MEMPOOL-MIB
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
DRAM usage shown in Prime network do not match with actual device usage.

Conditions:
ASR 1k devices

Workaround:
none.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2(2), 4.2(3), 4.3
Known Fixed Releases: *
4.1DP1603, 4.2(1)DP1603, 4.2(2), 4.2(2)DP1603, 4.2(3), 4.2DP1603
Alert Type:
Updated *
Bug Id:
CSCuv57682
Title:
Path Tracer fails to find trace route for PW originated on ASR9K VNE
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
When the Path Tracer is initiated from a pseudo-wire endpoint at the ASR9K VNE, the path shows only local interface. When the same operation is performed from the ME3600 VNE, it works properly showing full trace route.

Conditions:
Initiating Path Tracer on pseudo-wire from endpoint on ASR9K VNE.

Workaround:
Not known

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.2, 4.2(0.1)PP3, 4.2(1), 4.2(2), 4.3
Known Fixed Releases:
4.1(0.1)PP3, 4.2(0.1)PP4, 4.2(2.0)PP2
Alert Type:
New
Bug Id:
CSCva03202
Title:
Nexus 9k Enhancement in PN 4.2.3, PN 4.3 has some modelling issues
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
When we model Nexus 9k Device in PN43

Conditions:
Modelling has issues i.e., Physical inventory is not modeled correctly

Workaround:
NA

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3)DP1607.0.911, 4.3, 4.3(0X)DP0.0.911
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuw75611
Title:
Cmd Mng: Edit child job, hyperlink for parent job name got disabled
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Hyperlink to edit parent job is disabled

Conditions:
When trying to edit parent job through hyperlink

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2.0)PP2, 4.2(3.751), 4.3
Known Fixed Releases:
4.2(2.0)PP3, 4.2(3)
Alert Type:
New
Bug Id:
CSCva17014
Title:
PN - AVM Log errors associated with retrieving NCS6008 Serial Number
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
AVM Log shows errors for Fan Modules and no serial numbers are presented in the property panel of the Physical Inventory..

Conditions:
Modeling NCS6008 platform with dual Fan Module assembly

Workaround:
None

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3)DP1605.0.871, 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuv93513
Title:
PN - NullPointer in AVM log for ASR device on MPLS Interface removal
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
NullPointer Exception messages are being created in AVM log as a result of MPLS interface add/remove flow.

CorrelationFlowGetRootFaultBaseMH.checkForAlarmsOnPacket - checkForAlarmsOnPacket: 10.56.23.87 MPLS on interface GigabitEthernet0/2/0/0 Problem in Packet flow.

Conditions:
None

Workaround:
None

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(0.1)PP4, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCva15024
Title:
TenGig 10/1 missing from 7613 chassis with 76-ES+XT-4TG3C (slot 10)
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
TenGig 10/1 missing from 7613 chassis with 76-ES+XT-4TG3C (slot 10)

Conditions:
PN 4.2.2
DP 1605

Device: 7613 chassis with 76-ES+XT-4TG3C (slot 10)

Workaround:
None

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuy60638
Title:
PN-BGP IPv6 Label RoutingTable showing -1 for nolabel instances in ASR9k
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
Model ASR9k (10.56.25.147) and look at logical inventory. the incoming label column is showing a "-1" for instances where the value should be shown as "nolabel".

Conditions:
Model asr9k with mpls configuration. In NV view logical inventory.

Workaround:
No work around.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3)DP1603.0.821, 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCva16792
Title:
exception thrown in debug terminal when open Admin GUI Users
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
PN: Unable to view/assign maps to user in Admin GUI. This issue is caused by exception (shown in debug terminal of the Admin GUI) thrown when opening a user in Users in Admin GUI although the customer has multiple maps for a network with 5000+ devices.

Conditions:
PN 4.2.3

Workaround:
N.A.

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3.0)PP2, 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCva10597
Title:
EVNE not working for Nexus 9K(9236)
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
After changing any values or by creating a loopback, the status is not updating normally. it gets updated only after Poll now.

Conditions:
Model Nexus 9k and the status should be device reachable and operational.

Workaround:
NONE

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(0X)DP1607.0.881, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCva21014
Title:
IllegalArgumentException pop up when open Nexus 7K device VNE
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
The issue appears when Nexus 7K device VNE property is opened in NV, the following pop up exception will appear:

Java.lang.IllegalArgumentException: Invalid value for array property CDPService.

Conditions:
Nexus 7K device.
PN 4.2.2.0.6
DP 1605

Workaround:
N.A.

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuz23339
Title:
PN - IPv4 BGP routing entry for Nexus VDC is not presented
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
IPv4 BGP routing entry for Nexus VDC is not presented

Conditions:

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(0X)DP1605.0.842, 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuy91233
Title:
Nexus7K : Some ospfv2 interfaces are missing in OSPF interface table.
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:

Conditions:
1. Model Nexus7K that has OSPF v2
2. Open Nexus7K inventory

Workaround:
None

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCut65435
Title:
During failover from primary to secondary PPM links have to be updated
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
PPM cross launch links in the secondary are still pointed to Primary server even after Primary fails

Conditions:
Primary fails overs to Secondary PPM, cross launc

Workaround:
not known

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.0, 4.1, 4.2, 4.2(0.1)PP0, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCut50362
Title:
Wrong NCCM configuration in local HA setup
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
NCCM has configured the trap forwarding to the IP of the local machine and not to the floating IP.

In addition, the NCCM is listening to port 1167 on the local machine IP (not the floating IP).

When doing a switchover to the second gateway, the trap forwarding is still configured to the local IP of the first GW.

Conditions:
Local HA setup

Workaround:
Manually change the trap forwarding IP after switchover.

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2.582), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuy73605
Title:
User created AVM shows N/A in the memory consumption in PN422
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Check the memory consumption,it is showing as N/A.

Conditions:
User created AVM should display the memory consumption as Normal.

Workaround:
Prime Network Admin

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2.0)PP4, 4.2(3), 4.3
Known Fixed Releases:
4.2(1), 4.2(2), 4.2(3), 4.3(0.881)
Alert Type:
New
Bug Id:
CSCuy03137
Title:
LLDP link between devices doesn't show up in map view.
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Physical links between two ASR901s is not formed.

Conditions:
Model two ASR901s , create a map and add the devices to the map. The devices should be reachable and operational.

Workaround:
NONE

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3)DP0.0.811, 4.3
Known Fixed Releases:
4.1, 4.2, 4.2(1), 4.2(2), 4.2(3)
Alert Type:
New
Bug Id:
CSCuz25311
Title:
VNE stuck in Discovering forever
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
VNE is stuck in discovering state

Conditions:
This is very random and we do not know a particular scenario this happens

Workaround:
Restart AVM should fix the problem

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2.0)PP2, 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
New
Bug Id:
CSCuy81312
Title:
Associated Entities are missing in Interface and Neighbor in PIM
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Check for the Interface and neighbor Tabs in PIM.

Conditions:
Interface Hyperlinks has to come in Interface Tab and Neighbor links has to come in the Neighbor tab.

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(2)DP1603.0.812, 4.2(3), 4.3
Known Fixed Releases:
4.1, 4.2, 4.2(1), 4.2(2), 4.2(3)
Alert Type:
New
Bug Id:
CSCuy68103
Title:
PN - SQLException: ORA-12899 from VPLS and EVC name lengths
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Zip files containing database exceptions created every 3 minutes from java.lang.RuntimeException: java.sql.SQLException: ORA-12899

Conditions:
Long Names for VPLS and EVC

Workaround:
Reduce name lengths

Further Problem Description:

Last Modified:
02-JUL-2016
Known Affected Releases:
4.2(3), 4.2(3.0)PP1, 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw57111
Title:
NCCM dont show config archive when device banner login contain $
Status:
Open
Severity:
4 Minor
Description:

Symptom:
NCCM dont show config archive when device banner login contain $

Conditions:

Workaround:
remove the $ from device banner

Further Problem Description:

Last Modified:
28-JUN-2016
Known Affected Releases: *
4.2(0.1)PP2, 4.2(2.0)PP2, 4.2(3.0)PP2
Known Fixed Releases:
4.1(0.1)PP4, 4.2(0.1)PP6
Alert Type:
Updated *
Bug Id:
CSCur65803
Title:
Starting path trace from ethFlowPoint (EFP) doesn't take inner VLAN
Status:
Open
Severity:
4 Minor
Description:

Symptom:
When starting path trace from ethFlowPoint in EVC (in the service view map), choosing start and end point, path tracer does not include inner VLAN (if exist).

When doing the same from VNE inventory, starting from the EFP, it does take the inner VLAN.

Need to retrieve the inner VLAN in OpenPathToolBeginEthFlowPointCommandAction and in penPathToolEthFlowPointCommandAction.

Conditions:
Strat path trace from ethFLowPoint in EVC choosing start and end point with inner VLAN configuration.

Workaround:
None.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1, 4.1(0)PP3, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv90200
Title:
Pathtracer: Sometimes Layer 2 information is not displayed in results
Status:
Fixed
Severity:
4 Minor
Description:

Symptom:
When found path trace goes over DWDM DC the Layer 2 properties are not displayed in the Pathtracer results.

Conditions:
Path trace goes over DWDM DC.

Workaround:
There is no workaround for this issue.

Further Problem Description:

Last Modified:
01-JUL-2016
Known Affected Releases: *
4.1(0.1)PP3, 4.2, 4.2(0.1)PP4, 4.2(1), 4.2(2), 4.3
Known Fixed Releases:
4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(2.0)PP2
Alert Type:
Updated *
Bug Id:
CSCuq70018
Title:
user import from ldap ldif file fails, gives null ptr error
Status:
Fixed
Severity:
6 Enhancement
Description: *

Symptom:
ldap ldif import fails with null ptr error on cmd line and jvm trace in avm 11 log

Conditions:
* start import from a directory that is not ~/Main
* give absolute path for ldif file, or any path that is not current directory for ldif file

Workaround:
Steps:

login as prime network user

cd ~/Main

copy your ldif file to ~/Main

import_users_from_LDIF_file.pl yourfile.ldif



param-list you used: userPrincipalName description displayName email

This list of parameters don't appear to be correct.



The parameters required are as follows: [roleName]

ensure you use the correct parameters, and order of parameter, if it is not correct the import will not be correct.

Further Problem Description:

Last Modified:
29-JUN-2016
Known Affected Releases:
4.1(0)PP2
Known Fixed Releases:
4.1(0)PP3, 4.2(0.1)PP7, 4.2(2.0)PP6
Alert Type:
Updated *
Bug Id:
CSCui35119
Title:
NCCM - config restoration fail in device banner
Status:
Fixed
Severity:
6 Enhancement
Description:

Symptom:
Configuration restore operation fails.

Conditions:
Device banner is configured with caret sign(^c) or ETX char or apostrophe char.

Workaround:
caret sign(^c) or ETX char or apostrophe char should not be configured in banner.

Further Problem Description:

Last Modified:
14-JUN-2016
Known Affected Releases:
3.11(0.999)
Known Fixed Releases: *
4.1(0)PP3, 4.2(0.1)PP7, 4.2(2.0)PP2
Alert Type:
Updated *
Bug Id:
CSCuz55571
Title:
PN is archiving INFO events without clearing them
Status:
Open
Severity: *
6 Enhancement
Description:

Symptom:
FM has INFO events from PN which does not exist anymore

Conditions:
INFO tickets from PN

Workaround:
resync FM

Further Problem Description:

Last Modified:
06-JUN-2016
Known Affected Releases:
4.2(0.999)
Known Fixed Releases:

Find additional information in Bug Search index.

 