Alert Type: | New |
Bug Id: | CSCuz93525 | Title: | PN - DB framework - Oracle ConnectionPool and JDBC have blocking locks |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: AVM 11 threads can become blocked, critical code sections timeout and eventually cause a crash; leads to instability in AVM11, AVM25, AVM35, AVM44, AVM100, and XMP/NCCM
Conditions: One common trigger is a thread running a long query, most often related to Tickets.
Workaround: kill the affected query, and resolve anything that may be triggering the slowness in the query; or optimize the query
Further Problem Description:
|
|
Last Modified: | 03-JUN-2016 |
|
Known Affected Releases: | 4.3(0.999) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy22568 | Title: | CDPTest fails to match link endpoint between Nexus-5K VNEs |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: PN fails to discover Ethernet and physical links using CDP Test when link endpoint is located on Nexus-5K device. If link discovery can be accomplished only with CDP Test, the links will not be discovered.
Conditions: At least one endpoint of the physical link originates on Nexus-5K device and CDP enabled.
Workaround:
Further Problem Description:
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 4.2(2.0)PP4, 4.2(3) |
|
Known Fixed Releases: * | 4.2(0.1)PP7, 4.2(2.0)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv76305 | Title: | CCM: Edit Compliance audit job displays only 25 devices |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Device not found while editing already run compliance audit job. It does not show all the devices when editing compliance audit job. when selecting all the devices by clicking "select all" check box only 500 devices are selected on the right hand side.
Conditions: running prime network lower than 4.2.2
Workaround: instead of editing the job create a new one.
Further Problem Description:
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 4.2(1) |
|
Known Fixed Releases: * | 4.1(0.1)PP3, 4.2(0.1)PP7, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu60574 | Title: | CCM IOS-XR Image distribution Job is not added in Job page |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Schedule a Image distribution job in Prime network and it is not shown in Image job page.
Conditions: Primary Product: Prime Network CCM Component: Prime Network CCM Issues Version: 4.1(0) Patch Level: 4.1.0.1.0
Device type : IOS-XR
Workaround: None, this is fixed in Prime network 4.2.
Further Problem Description: none
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 4.1(0.1)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP2, 4.2(0.1)PP7, 4.2(2.0)PP4, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu93256 | Title: | PN - NCCM - Command Manager Preview fails |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Unable to preview Command Manager script output prior to execution Getting the following error: Can't find resource for bundle java.util.PropertyResourceBundle, key Unable to fetch DP name
Conditions: All Devices All Commands (new + predefined)
Workaround: None
Further Problem Description:
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(1.0)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP7 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCud00287 | Title: | VCB GUI will not display all brands modules of third party device |
|
Status: | Terminated |
|
Severity: | 3 Moderate |
Description: * | Symptom: 1) Module groups of only a few third-party vendors are displayed in the 'Modules' tab 2) Module group info is empty for a few third-party vendors when viewing vne-driver details in 'Drivers' tab
Conditions: Unknown. One possible condition could be the installation of 3.9 PP2 and/or PP3
Workaround: The user will have to use CLI command to add support for new modules.
Further Problem Description: The user will not be able to view existing module support or add support for new unsupported modules.
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 3.9(0)PP3, 4.2(0.1)PP4 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw42244 | Title: | Sometimes VNE get to Unsynchronized state due Telnet Collector timeout |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Some VNEs are falling to Currently Unsynchronized state due to Telnet Track Reachability Command failure in Telnet Collector.
Conditions: Very intensive use of Telnet collector.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 4.2(0.1)PP4 |
|
Known Fixed Releases: * | 4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(0.1)PP7, 4.2(2.0)PP3, 4.2(2.0)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu81578 | Title: | PN - NCCM - Config Archives - Version hyperlink does not show config |
|
Status: * | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: The archived config for ASR5k is not presented when clicking the hyperlink presented in the "Version" column of the Configuration Archive screen. The user is presented with the following output instead: {"items":"max_e"}
Conditions: None
Workaround: Archived config is viewable from the Edit Option instead.
Further Problem Description:
|
|
Last Modified: | 15-JUN-2016 |
|
Known Affected Releases: | 4.2(1.0)PP1, 4.2(2.651) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv16808 | Title: | ASR9K satellite IC links not appear in ASR9K 5.3.1 |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: ASR9K satellite IC links not appear in ASR9K 5.3.1. Tested in Satellite ring and cascasing topologies
Conditions: 1. Model ASR9K SW version 5.3.1 with satellite
Workaround:
Further Problem Description:
|
|
Last Modified: | 23-JUN-2016 |
|
Known Affected Releases: * | 4.2(0X)DP1505.0.622, 4.2(2)DP1511.0.742, 4.2(3)DP1605.0.871 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCva18254 | Title: | P-FM:PN or PPM TCA alarm don't receive in FM via prime network |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: While Fault Management installed in different server than PC the Ticket alarm from prime network doesn't receive
Conditions: Install PC in different server and also Install FM in different server. Integrate PP,PPM and PN while a new ticket receive in prime network those alarm should forward to FM->PC and then we see the alarms didn't receive under alarm browser. in rder to see those alarm I have to run "fmctl resync" command from FM server
Workaround: run "fmctl resync" and then all alarms will be update but the new alarms that will arrive willn't be update hence require again run "fmctl resync"
Further Problem Description: PN is not forwarding any ticket updates to PC/FM.
|
|
Last Modified: | 28-JUN-2016 |
|
Known Affected Releases: * | 4.2(3.0)PP2 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva27050 | Title: | ASR9912 VNE fails to parse %PLATFORM syslog messages |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: During fan tray OIR tests it was noticed that ASR9912 VNE fails to parse %PLATFORM-INV, %PLATFORM-SHELFMGR and %PLATFORM-ENVMON syslog messages.
Conditions: ASR9912 VNE, fan tray OIR
Workaround: none
Further Problem Description:
|
|
Last Modified: | 29-JUN-2016 |
|
Known Affected Releases: | 4.2(2)DP1605.0.871 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv06547 | Title: | Nexus7K do not show OSPF v2 neighborswhen OSPF v2 and v3 has the same id |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: Nexus7K do not show OSPF v2 neighbors when OSPF v2 and v3 has the same process id
Conditions: 1. Model Nexus7K that has OSPF v2 and v3 with the same process id 2. Open Nexus7K inventory 2. Go to OSPF v3 and see if it has neighbors
Workaround: NA
Further Problem Description:
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2, 4.2(1), 4.2(2), 4.2(3) |
|
Known Fixed Releases: | 4.2(2.0)PP6 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCux26688 | Title: | Native flow:Distribute and Activate of pie files for future time fails |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Distribution and activation operation for future time fails.
Conditions: Activation of future time fails
Workaround: Perform Activation separately after distribution is completed.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2(2.0)PP3, 4.2(3) |
|
Known Fixed Releases: | 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCux00529 | Title: | bosmanageplugin not loaded in avm 11 after redundant unit is configured |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: After configuring a redundant unit , the subsequent launching of GUI will be locked up after avm 11 restart.
Conditions: PN 4.2.2 A reduendant unit is configured and avm 11 is restarted subsequently
Workaround: N.A.
Further Problem Description:
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2(2.0)PP1, 4.2(2.0)PP2 |
|
Known Fixed Releases: | 4.2(2.0)PP3, 4.2(3.0)PP1, 4.3(0.881) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz34856 | Title: | PN - NCCM device family for Nexus 5k is shown as MDS9222i |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: NCCM device family for Nexus 5k is shown as MDS9222i
Conditions: From NCCM, if the user is selecting device for Image Management, there is a combo-box that allsows for sorting all devices based on Device Family. The Nexus 5k devices are being categorized under a family type = MDS9222i.
MDS922i is for the Cisco ? MDS 9222i Multiservice Modular Switch.
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2(3)DP1603.0.821 |
|
Known Fixed Releases: | 4.1, 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCux18621 | Title: | Email notification not working for Import from devices. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Import from devices does not trigger any mail for the Job completion.
Conditions: For all devices the issue is seen.
Workaround: Check the Job details in CCM Page.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2(2.0)PP3 |
|
Known Fixed Releases: | 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCux75862 | Title: | View button is enabled for Compliance-audit-mail job at All Jobs page |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: View button is enabled for Compliance-audit-mail job
Conditions: 1.Launch CCM application 2.Login as root User 3.Navigate to Compliance Audit-->Jobs 4.Select any Compliance-audit-mail job
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 30-JUN-2016 |
|
Known Affected Releases: | 4.2(3.791) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCva00517 | Title: | Nexus6001: Evil twin DC errors for Power Supply modules |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: While modeling Nexus 6001 devices it was noticed that VNE logs multiple error messages "evil twin DC" for Power Supply modules.
Conditions: Modeling device Nexus 6001
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.1, 4.2, 4.2(2), 4.2(3) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCut88602 | Title: | ppm reports url in PN is pointing the wrong machine in DR setup |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: ppm cross launch report is not working from Network Vision - pointing to the wrong GW
Conditions: GEO HA (DR) setup, after switchover
Workaround: change in site.xml to the correct url (correct hostname)
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.2(0)PP999, 4.2(1), 4.2(2), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur60321 | Title: | Got an error when changing the PN gateway IP Address |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: When changing the PN gateway IP address through the script $HOME/Main/scripts/change_gw_ip.pl.
Got the error--" Failed to start Prime Network System is already up"
Conditions: When changing the PN gateway through scripts
Workaround: Restart the primenetwork as prime user by using the command (networkctl restart).
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(1), 4.2(1.491), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux80765 | Title: | rsync_monitor_db.cmd on primary GEO ha node interfer with upgrade |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: upgrade on GEO HA fails
Conditions: the following cron job is running on the primary node:
0,10,20,30,40,50 * * * * if [ -f /export/home/pnetwork/.local_ana ]; then /var/adm/cisco/prime-network/scripts/ha/rsync/rsync_monitor_db.cmd > /dev/null 2>&1; fi
Workaround: before upgrade, upgrade the following line in cron list on primary:
0,10,20,30,40,50 * * * * if [ -f /export/home/pnetwork/.local_ana ]; then /var/adm/cisco/prime-network/scripts/ha/rsync/rsync_monitor_db.cmd > /dev/null 2>&1; fi
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.0(0.1)PP2, 4.1, 4.2, 4.2(0.1)PP0, 4.2(1), 4.2(2), 4.2(3), 4.3, 4.3(0.999) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCut05115 | Title: | EFP ->Reg& PBBbridge->vfi->pwThe vfi forms an incorrect link with d EFP. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: When an EFP and VFI are connected to a bridge (Regular or PBB bridge ), the VFI and EFP form incorrect links with each other. On expanding the VFI, the EFP is again contained in it and again form a link with the VFI within it)
Conditions: On dropping down a bridge with an EFP connected to it from Add to Map ->Bridge domains and an associated VFI from Add to Map-> VPLS, the VFI from a link with the EFP .
Workaround: No workaround available
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(1), 4.2(1)DP0.0.561, 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz52738 | Title: | ASR1K , does not have QOS container |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: ASR 1k does not have QOS container
Conditions: 1) Model ASR 1k 10.56.25.155 . 2) Create QOS policy in any interface . 3) Check the QOS container in the Logical inventory .
Workaround:
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.1, 4.1(0.1)PP4, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz72978 | Title: | When Ethernet port is a member of LACP, the LldpTest fails discover link |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: PN fails discover physical links for some pairs of routers connected over LACP aggregation, although the LLDP inventory is present and correct.
Conditions: LLDP neighbor table contains records where remote port ID is LACP aggregation.
Workaround: none
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2), 4.2(2.0)PP6, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.2(0.1)PP7, 4.2(2), 4.2(3) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy20029 | Title: | Newly added syslogs and traps to ipcore via VCB are not parsed by 76xx |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: The newly added ipcore syslogs via VCB are not getting into the syslog instead it goes to standard (generic) syslog.
Conditions: Added to ipcore syslogs (cisco-syslog-ipcore-parsing-rules)
Workaround: Syslog: ====== runRegTool.sh -gs 127.0.0.1 add 0.0.0.0 site/cisco-6500-syslog-product-parsing-rules success runRegTool.sh -gs 127.0.0.1 set 0.0.0.0 site/cisco-6500-syslog-product-parsing-rules/default cisco-syslog-ipcore-parsing-rules
This will work for 76xx if we do not have 6500 modelled in the same setup.
Trap: ==== unRegTool.sh -gs 127.0.0.1 add 0.0.0.0 site/cisco-6500-trap-product-parsing-rules success runRegTool.sh -gs 127.0.0.1 set 0.0.0.0 site/cisco-6500-trap-product-parsing-rules/default cisco-trap-ipcore-parsing-rules
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2)DP1509.0.671, 4.2(2)DP1601.0.751, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.1DP1603, 4.2(1)DP1603, 4.2(2)DP1603, 4.2(3), 4.2DP1603 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus71242 | Title: | DLP file manament causes gateway CPU use nears 100 or proc collisions |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Symptoms:
Severe: * Users can see many instances of scripts being active. * many processes of command 'lsof' * the DLP Output folder continues to grow
Mild: * Event Vision fills with errors/warnings regarding failure to move files from the DLP Output folder for example: Checksum compare is failing between /infobright_dlp/ifb_dlp_data/DLP_Output_Files and /infobright_backup/ifb_backup * Event Vision warnings may not be very frequent maybe 4-5 times daily.
Conditions: there are number of scripts being executed as root from the crontab. The scripts have no protections against long runs of the script. The lack of protection leads to severe CPU and filesystem troubles.
This bug is for /var/adm/cisco/infobright/move_dlp_files.sh ; however the scripts in the same folder should be checked if any protections need to be used for their executions
The severe symptoms occur because of a very large backlog which can be because of systems being down for a long time or connectivity issues to the active gateway.
Workaround: to prevent server failure:
-fix missing ssh key issue for infobright scripts: ssh-keygen -f /var/adm/cisco/infobright/.ssh/id_rsa -N '' cat /var/adm/cisco/infobright/.ssh/id_rsa.pub >> ~/.ssh/authorized_keys
-send keys to all pn hosts, gatways and units: cd /var/adm/cisco/infobright/.ssh/ scp -p * :/var/adm/cisco/infobright/.ssh
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0.342), 4.2, 4.2(0.522), 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu43463 | Title: | PW link between ASR902 to other device disappear with no alarm after car |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: PW link between ASR902 to other device disappear with no alarm after card out.
The link disappear because PW container disappear from VNE inventory. and PW tunnel down trap from other side not correlate and not create any ticket
Conditions: 1. Model ASR902, and SAR9K 2. Card out ASR902 card
Workaround:
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.1, 4.1(0)PP1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuq71407 | Title: | TP snapshot is not being updated |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: TP snapshot is not getting updated properly.
Conditions: When VNE or AVM is stopped, relevant elements in the snapshot gets deleted. It is geeting getting deleted only after 2-3 minutes. If the AVM/VNE is stopped and started immediately then the snapshot is not updated. Elements are deleted from the snapshot only after 2-3 minutes and never added once again.
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0)PP999, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCva17377 | Title: | Failure retrieve software version after initialization shuts down VNE |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When SNMP connectivity is restored after VNE developed Device Unreachable and then lost again, the failure to get device software version shuts down VNE.
Conditions: Unstable SNMP connectivity with the device
Workaround: Restart VNE.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(3.0)PP2, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux95534 | Title: | LLDP neihbors details are not modeld in PN for ME1200 |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: LLDP neighbors details are not modeled in PN.
Conditions: 1. Modeled the two ME1200 devices. 2. Physically connect it (Gig 1/3-3,1/4-4) 3. Configure the LLDP through CLI/Command scriptin vision GUI 4. get show LLDP neighbor response using soap UI.
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1(0X)DP1601.0.772, 4.2(0X)DP1601.0.772, 4.2(1)DP1601.0.772, 4.2(2), 4.2(2)DP1601.0.772, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy38751 | Title: | NCS:Redundancy state of RP's not shown in the VNE |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Redundancy state is updated for RP's.
Conditions: When NCS has HA setup.
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2)DP1601.0.752, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCut06773 | Title: | Subinterface&Pw of a regular bridge are incorrectly contained in EVC |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: The components (Sub interface or EFP) connected to a regular bridge with an association such as pseudowire or vfi are shown in EVC discovery as separate entities and does not represent the actual connection of the components ie EFP/Subinterface ->Regular bridge ->Association (vfi/pseudowire) This is because Regular bridges with associations are not displayed in bridge domain discovery (Feature implementation ).Hence, the components such as EFP /L3-Sub-interface will be contained in the EVC discovery along with the association such as vfi or pseudo wire without the regular bridge connecting them and hence is misleading as it will display only the name of the regular bridge which actually joins both the component and the association
Conditions: From Add to Map->EVC discovery an EVC of the association ie vfi or pseudowire of the regular bridge and the components such as EFP or L3-subinterface is formed without actually representing the exact network scenario as regular bridges will not be discovered as part of Bridge domain discovery
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(1), 4.2(1)DP0.0.552, 4.2(1)DP0.0.561, 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw34406 | Title: | PN - NetworkVlanDiscoveryPlugin - Placeholder OID not found exception |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Network VLAN Discovery Logs are rolling over with constant notifications when Nexus7k device is modeled from lab. Also these notifcication excetions are being written to 35.out log as well causing them to fill up as well.
Notification is coming from the following: java.lang.IllegalArgumentException: Placeholder OID not found
Conditions: None
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(0.1)PP5, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux59041 | Title: | Link down on unreachable alarm has broken location and not clean |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Link down on unreachable alarm has broken location and not clean
Symptom: Link down on unreachable alarm has broken location and not clean
Conditions: 1. Model ASR9K 2. Shutdown link
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.1, 4.2, 4.2(1), 4.2(2), 4.2(2.0)PP3, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz56859 | Title: | ArrayIndexOutOfBoundsException in DcOidMapping when Get fails with excep |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: VNE develops ArrayIndexOutOfBoundsException in DcOidMapping when Get fails to translate Oid to PropertyHolder with exception, beaks handling of exception.
Conditions: Get fails to translate Oid to PropertyHolder with exception and Oid string representation does not contain string "ContextName". For example PortOid for unassigned interfaces in Nexus7K or any legacy VNE with no contexts.
Workaround: none
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2), 4.2(2.0)PP6, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.2(0.1)PP7, 4.2(2), 4.2(3) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy74775 | Title: | CCM: Nexus 7k Config backup fails using SFTP except for default VDC |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Config backup fails for all VDC (except default VDC).
Conditions: device : Nexus 7k. Transfer protocol: SFTP.
Workaround: Use other transfer protocols if management VRF is used.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2)DP1601.0.791, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuh56824 | Title: | Longer VNE Deletion time observed when 7K VM's vCenter deleted |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Deleting/stopping a large scale VCenter VNE takes a long time. For example, if a VCenter with 5000 or 7000 VMs is stopped or deleted, it takes 10 to 15 min for 5000 VMs and 25 min to 40 min for 7000 VMs.
Conditions: Happens only for large scale VCenter where it has 5000 VMs or more.
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.0(0.131), 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux56356 | Title: | webstart CCM link converts dashboard page to CCM login page |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Webstart launch page ( http://:6080/ana/services/install/install/webstart.html) gets redirected to CCM login page.
Conditions: On clicking CCM link in webstart page.
Workaround: none.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2.0)PP3, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.2(0.1)PP6, 4.2(2.0)PP4, 4.2(3), 4.3 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuo86912 | Title: | EFD not split after link down. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: EFD not split after link down and they stayed in one efd and no service alarm for efd split has been generated.
Conditions: Steps to reproduce: :
We have the link: AGG1-6524ME-NY-rec#GigabitEthernet1/28 ----- GG-6500-NY-rec# GigabitEthernet3/9 in up state And A & Z sides of the above link are in same efds Then we're shutting down the link Then we expected to see that A & Z sides of the above link are in different efds, but they stayed in one efd and of course no service alarm for efd split has been generated.
in addition we have empty container in Ethernet Flow Domain
Workaround: N/A
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0.322), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus31118 | Title: | Operation Report install script fails in Local HA config |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Install fails and or the cluster.conf becomes corrupted by poor processing of the file.
Conditions: * Local HA setup, with mapper partitions. * Cluster configured and could be re-written by system tools after initial install by PN.
Workaround: None, script fix required.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0.342), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux91431 | Title: | SONET/POS properties are missing |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: SONET/POS properties are missing
Conditions: Cisco ASR903 + SONET/POS/Controller specific port configuration
Workaround: We can see the properties in the Mediator Debugger or by pressing F2 on the interface
Further Problem Description: None
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1(0X)DP1601.0.772, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3, 4.3(0X)DP0.0.911 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy39072 | Title: | SNMP track reachability does not reset retry counter when device reload |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: SNMP track reachability command does not reset retry counter when device is reloaded. As a result the VNE creates Device Unreachable alarm prematurely.
Conditions: Number of retries for SNMP track reachability command is changed to more than 1
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2.0)PP4, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP7, 4.2(2.0)PP6, 4.3(0.881) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw40593 | Title: | PN failed to discover MPLS link between ASR903 and ASR920 |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Some of the MPLS links, especially those originated on ASR920 VNEs are missing in topology.
Conditions: Configuration of MPLS network with ASR920.
Workaround: There is no workaround for this issue
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.2, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.2, 4.2(1), 4.2(2), 4.2(2.0)PP2, 4.2(3), 4.2(3.0)PP1, 4.3 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuq17839 | Title: | P-PN: Chassis disconnect for satellite is not developed with card down |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Satellite Chassis Disconnect service alarm ticket isn't generated.
Conditions: On performing card down for the card that is connected to satellite.
Workaround: None
Further Problem Description: The card down should be performed after ASR9k with Satellite is fully modeled and the the link between two chassis is discovered.
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0)PP1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw28932 | Title: | Oper Reports - temp folder is not cleaned clogging file system |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Operation Report temporary files clogging disk space and causes the AVM25 process to stall
Conditions: * perform a backup / restore while file are present in the temp folder
Workaround: manually clear temporary file folder while PN is down, or delete all files that are exceedingly old
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1(0.1)PP2, 4.2, 4.2(0.1)PP4, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy28373 | Title: | PN - major upgrade script error while updating perms |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: * error seen while running upgrade from PN 4.1: Can't call method "perm" on an undefined value at ./upgrade.pl line 3242. * upgrade exists with this error
Conditions: * Upgrade from older major release to latest release: PN 4.2.2 * single gateway, no units
Workaround: modify the script as described and rerun.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2), 4.2(2.999), 4.2(3), 4.2(3.832), 4.3 |
|
Known Fixed Releases: * | 4.2(3) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCun47761 | Title: | EFP missing from on the pseudowire and EVC service view |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: Missing EFP in EVC view. This issue does not happen consistently.
Conditions: Deletion of EFP from Pseudowires and re-adding may be the cause.
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0.321), 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCup02954 | Title: | SFP pluggable status is not refreshing while performing SFP in/out. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: SFP pluggable status is not refreshing while performing SFP OIR.
Conditions: Perform SFP OIR.
Workaround: Moving the cursor location updates the SFP attributes.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.0, 4.0(0.1)PP4, 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy20868 | Title: | ASR1K to use new 64bit MIB parameters of CISCO-ENHANCED-MEMPOOL-MIB |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: DRAM usage shown in Prime network do not match with actual device usage.
Conditions: ASR 1k devices
Workaround: none.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: * | 4.1DP1603, 4.2(1)DP1603, 4.2(2), 4.2(2)DP1603, 4.2(3), 4.2DP1603 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv57682 | Title: | Path Tracer fails to find trace route for PW originated on ASR9K VNE |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When the Path Tracer is initiated from a pseudo-wire endpoint at the ASR9K VNE, the path shows only local interface. When the same operation is performed from the ME3600 VNE, it works properly showing full trace route.
Conditions: Initiating Path Tracer on pseudo-wire from endpoint on ASR9K VNE.
Workaround: Not known
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.2, 4.2(0.1)PP3, 4.2(1), 4.2(2), 4.3 |
|
Known Fixed Releases: | 4.1(0.1)PP3, 4.2(0.1)PP4, 4.2(2.0)PP2 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva03202 | Title: | Nexus 9k Enhancement in PN 4.2.3, PN 4.3 has some modelling issues |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When we model Nexus 9k Device in PN43
Conditions: Modelling has issues i.e., Physical inventory is not modeled correctly
Workaround: NA
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3)DP1607.0.911, 4.3, 4.3(0X)DP0.0.911 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuw75611 | Title: | Cmd Mng: Edit child job, hyperlink for parent job name got disabled |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Hyperlink to edit parent job is disabled
Conditions: When trying to edit parent job through hyperlink
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2.0)PP2, 4.2(3.751), 4.3 |
|
Known Fixed Releases: | 4.2(2.0)PP3, 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva17014 | Title: | PN - AVM Log errors associated with retrieving NCS6008 Serial Number |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: AVM Log shows errors for Fan Modules and no serial numbers are presented in the property panel of the Physical Inventory..
Conditions: Modeling NCS6008 platform with dual Fan Module assembly
Workaround: None
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3)DP1605.0.871, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuv93513 | Title: | PN - NullPointer in AVM log for ASR device on MPLS Interface removal |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: NullPointer Exception messages are being created in AVM log as a result of MPLS interface add/remove flow.
CorrelationFlowGetRootFaultBaseMH.checkForAlarmsOnPacket - checkForAlarmsOnPacket: 10.56.23.87 MPLS on interface GigabitEthernet0/2/0/0 Problem in Packet flow.
Conditions: None
Workaround: None
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(0.1)PP4, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva15024 | Title: | TenGig 10/1 missing from 7613 chassis with 76-ES+XT-4TG3C (slot 10) |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: TenGig 10/1 missing from 7613 chassis with 76-ES+XT-4TG3C (slot 10)
Conditions: PN 4.2.2 DP 1605
Device: 7613 chassis with 76-ES+XT-4TG3C (slot 10)
Workaround: None
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy60638 | Title: | PN-BGP IPv6 Label RoutingTable showing -1 for nolabel instances in ASR9k |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: Model ASR9k (10.56.25.147) and look at logical inventory. the incoming label column is showing a "-1" for instances where the value should be shown as "nolabel".
Conditions: Model asr9k with mpls configuration. In NV view logical inventory.
Workaround: No work around.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3)DP1603.0.821, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva16792 | Title: | exception thrown in debug terminal when open Admin GUI Users |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: PN: Unable to view/assign maps to user in Admin GUI. This issue is caused by exception (shown in debug terminal of the Admin GUI) thrown when opening a user in Users in Admin GUI although the customer has multiple maps for a network with 5000+ devices.
Conditions: PN 4.2.3
Workaround: N.A.
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3.0)PP2, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva10597 | Title: | EVNE not working for Nexus 9K(9236) |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: After changing any values or by creating a loopback, the status is not updating normally. it gets updated only after Poll now.
Conditions: Model Nexus 9k and the status should be device reachable and operational.
Workaround: NONE
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(0X)DP1607.0.881, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCva21014 | Title: | IllegalArgumentException pop up when open Nexus 7K device VNE |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: The issue appears when Nexus 7K device VNE property is opened in NV, the following pop up exception will appear:
Java.lang.IllegalArgumentException: Invalid value for array property CDPService.
Conditions: Nexus 7K device. PN 4.2.2.0.6 DP 1605
Workaround: N.A.
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2), 4.2(2)DP1605.0.871, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz23339 | Title: | PN - IPv4 BGP routing entry for Nexus VDC is not presented |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: IPv4 BGP routing entry for Nexus VDC is not presented
Conditions:
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(0X)DP1605.0.842, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy91233 | Title: | Nexus7K : Some ospfv2 interfaces are missing in OSPF interface table. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom:
Conditions: 1. Model Nexus7K that has OSPF v2 2. Open Nexus7K inventory
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCut65435 | Title: | During failover from primary to secondary PPM links have to be updated |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: PPM cross launch links in the secondary are still pointed to Primary server even after Primary fails
Conditions: Primary fails overs to Secondary PPM, cross launc
Workaround: not known
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.0, 4.1, 4.2, 4.2(0.1)PP0, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCut50362 | Title: | Wrong NCCM configuration in local HA setup |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: NCCM has configured the trap forwarding to the IP of the local machine and not to the floating IP.
In addition, the NCCM is listening to port 1167 on the local machine IP (not the floating IP).
When doing a switchover to the second gateway, the trap forwarding is still configured to the local IP of the first GW.
Conditions: Local HA setup
Workaround: Manually change the trap forwarding IP after switchover.
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2.582), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy73605 | Title: | User created AVM shows N/A in the memory consumption in PN422 |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Check the memory consumption,it is showing as N/A.
Conditions: User created AVM should display the memory consumption as Normal.
Workaround: Prime Network Admin
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2.0)PP4, 4.2(3), 4.3 |
|
Known Fixed Releases: | 4.2(1), 4.2(2), 4.2(3), 4.3(0.881) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy03137 | Title: | LLDP link between devices doesn't show up in map view. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Physical links between two ASR901s is not formed.
Conditions: Model two ASR901s , create a map and add the devices to the map. The devices should be reachable and operational.
Workaround: NONE
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3)DP0.0.811, 4.3 |
|
Known Fixed Releases: | 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz25311 | Title: | VNE stuck in Discovering forever |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: VNE is stuck in discovering state
Conditions: This is very random and we do not know a particular scenario this happens
Workaround: Restart AVM should fix the problem
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2.0)PP2, 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy81312 | Title: | Associated Entities are missing in Interface and Neighbor in PIM |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Check for the Interface and neighbor Tabs in PIM.
Conditions: Interface Hyperlinks has to come in Interface Tab and Neighbor links has to come in the Neighbor tab.
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(2)DP1603.0.812, 4.2(3), 4.3 |
|
Known Fixed Releases: | 4.1, 4.2, 4.2(1), 4.2(2), 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuy68103 | Title: | PN - SQLException: ORA-12899 from VPLS and EVC name lengths |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Zip files containing database exceptions created every 3 minutes from java.lang.RuntimeException: java.sql.SQLException: ORA-12899
Conditions: Long Names for VPLS and EVC
Workaround: Reduce name lengths
Further Problem Description:
|
|
Last Modified: | 02-JUL-2016 |
|
Known Affected Releases: | 4.2(3), 4.2(3.0)PP1, 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw57111 | Title: | NCCM dont show config archive when device banner login contain $ |
|
Status: | Open |
|
Severity: | 4 Minor |
Description: | Symptom: NCCM dont show config archive when device banner login contain $
Conditions:
Workaround: remove the $ from device banner
Further Problem Description:
|
|
Last Modified: | 28-JUN-2016 |
|
Known Affected Releases: * | 4.2(0.1)PP2, 4.2(2.0)PP2, 4.2(3.0)PP2 |
|
Known Fixed Releases: | 4.1(0.1)PP4, 4.2(0.1)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur65803 | Title: | Starting path trace from ethFlowPoint (EFP) doesn't take inner VLAN |
|
Status: | Open |
|
Severity: | 4 Minor |
Description: | Symptom: When starting path trace from ethFlowPoint in EVC (in the service view map), choosing start and end point, path tracer does not include inner VLAN (if exist).
When doing the same from VNE inventory, starting from the EFP, it does take the inner VLAN.
Need to retrieve the inner VLAN in OpenPathToolBeginEthFlowPointCommandAction and in penPathToolEthFlowPointCommandAction.
Conditions: Strat path trace from ethFLowPoint in EVC choosing start and end point with inner VLAN configuration.
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1, 4.1(0)PP3, 4.2, 4.2(1), 4.2(2), 4.2(3), 4.3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv90200 | Title: | Pathtracer: Sometimes Layer 2 information is not displayed in results |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: When found path trace goes over DWDM DC the Layer 2 properties are not displayed in the Pathtracer results.
Conditions: Path trace goes over DWDM DC.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 01-JUL-2016 |
|
Known Affected Releases: * | 4.1(0.1)PP3, 4.2, 4.2(0.1)PP4, 4.2(1), 4.2(2), 4.3 |
|
Known Fixed Releases: | 4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(2.0)PP2 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuq70018 | Title: | user import from ldap ldif file fails, gives null ptr error |
|
Status: | Fixed |
|
Severity: | 6 Enhancement |
Description: * | Symptom: ldap ldif import fails with null ptr error on cmd line and jvm trace in avm 11 log
Conditions: * start import from a directory that is not ~/Main * give absolute path for ldif file, or any path that is not current directory for ldif file
Workaround: Steps:
login as prime network user
cd ~/Main
copy your ldif file to ~/Main
import_users_from_LDIF_file.pl yourfile.ldif
param-list you used: userPrincipalName description displayName email
This list of parameters don't appear to be correct.
The parameters required are as follows: [roleName]
ensure you use the correct parameters, and order of parameter, if it is not correct the import will not be correct.
Further Problem Description:
|
|
Last Modified: | 29-JUN-2016 |
|
Known Affected Releases: | 4.1(0)PP2 |
|
Known Fixed Releases: | 4.1(0)PP3, 4.2(0.1)PP7, 4.2(2.0)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCui35119 | Title: | NCCM - config restoration fail in device banner |
|
Status: | Fixed |
|
Severity: | 6 Enhancement |
Description: | Symptom: Configuration restore operation fails.
Conditions: Device banner is configured with caret sign(^c) or ETX char or apostrophe char.
Workaround: caret sign(^c) or ETX char or apostrophe char should not be configured in banner.
Further Problem Description:
|
|
Last Modified: | 14-JUN-2016 |
|
Known Affected Releases: | 3.11(0.999) |
|
Known Fixed Releases: * | 4.1(0)PP3, 4.2(0.1)PP7, 4.2(2.0)PP2 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz55571 | Title: | PN is archiving INFO events without clearing them |
|
Status: | Open |
|
Severity: * | 6 Enhancement |
Description: | Symptom: FM has INFO events from PN which does not exist anymore
Conditions: INFO tickets from PN
Workaround: resync FM
Further Problem Description:
|
|
Last Modified: | 06-JUN-2016 |
|
Known Affected Releases: | 4.2(0.999) |
|
Known Fixed Releases: | |
|
|
| |
没有评论: