| | Title: | End-of-Sale and End-of-Life Announcement for the Cisco IOS XE Software 3.7.0E for Cisco Catalyst 4500-E/X Series Switches and Cisco IOS 15.2(3)E for Cisco Catalyst 2960-X/XR, 2960-Plus, 2960 C/CX, 3750-X, 3560-X/CX, and 4900 Series Switches | Description: | Cisco announces the end-of-sale and end-of-life dates for the Cisco IOS XE Software 3.7.0E for Cisco Catalyst 4500-E/X Series Switches and Cisco IOS 15.2(3)E for Cisco Catalyst 2960-X/XR, 2960-Plus, 2960-C/CX, 3750-X, 3560-X/CX, and 4900 Series Switches. The last day to order the affected product(s) is October 28, 2016. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Table 1 describes the end-of-life milestones, definitions, and dates for the affected product(s). For customers with active and paid service and support contracts, support will be available under the terms and conditions of customers' service contract. Click here for the French Version of this Bulletin. | Date: | 02-MAY-2016 | |
|
| | | | Title: | End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 4500E Line Cards | Description: | Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 4500E Line Cards. The last day to order the affected product(s) is April 30, 2017. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Table 1 describes the end-of-life milestones, definitions, and dates for the affected product(s). Table 2 lists the product part numbers affected by this announcement. For customers with active and paid service and support contracts, support will be available under the terms and conditions of customers' service contract. Click here for the French Version of this Bulletin. | Date: | 02-MAY-2016 | |
|
| | | | Title: | End-of-Sale and End-of-Life Announcement for the Cisco UPOE Power Splitter | Description: | Cisco announces the end-of-sale and end-of-life dates for the Cisco UPOE Power Splitter. The last day to order the affected product(s) is October 29, 2016. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Table 1 describes the end-of-life milestones, definitions, and dates for the affected product(s). Table 2 lists the product part numbers affected by this announcement. For customers with active and paid service and support contracts, support will be available under the terms and conditions of customers' service contract. Click here for the French Version of this Bulletin. | Date: | 04-MAY-2016 | |
|
| |
Known Bugs - Catalyst 4500 Series Switches
| | |
Alert Type: | Updated * | Bug Id: | CSCuu34535 | Title: | Standby reloads on removing flow monitor | |
Status: | Fixed | |
Severity: | 2 Severe | Description: | Symptom: In a VSS standby reloads due to config sync on removing flow monitor
Conditions: This issue only happens when we apply flow monitor to SVI using Vlan configuration and remove Vlan config prior to removing Flow monitor
Workaround: None
Further Problem Description:
| |
Last Modified: | 24-MAY-2016 | |
Known Affected Releases: | 15.2(2)E, 15.2(2)E1, 15.2(2)E2, 15.2(3)E | |
Known Fixed Releases: * | 15.2(5.2.5i)E | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCut93424 | Title: | CAT4500 - Flexible Netflow start/end time inaccuracy | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: * | Symptom: Incorrect Netflow timestamp: when there are large number of flows are there it is seen that for some of flows last time stamps is lower than first time stamp that is not proper so in this case delta (last-first) timestamp is negative while delta(last-first) should be always positive. ================================== show flow monitor NETFLOW-V4 cache Cache type: Normal Cache size: 100 Current entries: 95 High Watermark: 100
Flows added: 1024750 Flows aged: 1024655 - Active timeout ( 10 secs) 0 - Inactive timeout ( 5 secs) 143 - Event aged 0 - Watermark aged 147 - Emergency aged 1024365 timestamp first: 21:09:10.563 >>>>>>>>>>>>>>>>>>>first timestamp is higher than last time stamp timestamp last: 21:09:09.415 >>>>>>>>>>>>>>>>>>>last time stamp should be greater than first time stamp
Conditions: Endtime timestamp is lower than the StartTime.
Workaround: N/A
Further Problem Description:
| |
Last Modified: | 31-MAY-2016 | |
Known Affected Releases: | 15.1(2)SG4 | |
Known Fixed Releases: | 15.2(4)E1, 15.2(5.0.82)E, 15.2(5.5.63)E, 15.2(5.5.64)E, 3.8(1)E | |
|
| | | | |
Alert Type: | New | Bug Id: | CSCuz87940 | Title: | Invalid vlan policy in startup-config make running-config inaccessible | |
Status: | Open | |
Severity: | 3 Moderate | Description: | Symptom: Switch crashes on accessing running configuration or vlan configuration.
Conditions: Conflicting VLAN configuration policy in startup-config
Workaround:
Further Problem Description:
| |
Last Modified: | 31-MAY-2016 | |
Known Affected Releases: | 3.6(3)E, 3.7(3)E, 3.8(1)E | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCun79400 | Title: | System image file is absent in show version | |
Status: | Open | |
Severity: | 4 Minor | Description: * | Symptom: Cat4500 does not display "System image file" in show version output unless config-register is 0x2102. This is seen with or without bootvar set. Can be seen on both sup7 and sup8 based cat4500. Bootvar set, config-register = 0x102 or 0x2101, system image name is NOT shown in show ver. Only when config register is set to 0x2102 and switch reloaded, system image file appears in show ver. System image file is "bootflash:cat4500es8-universal.SPA.03.03.00.XO.151-1.XO.bin Other platforms (like 3850) do show system image file name irrespective of what the config-register is.
Conditions: NA
Workaround: NA
Further Problem Description: NA
| |
Last Modified: | 19-MAY-2016 | |
Known Affected Releases: | 15.1(1)XO0.1 | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | New | Bug Id: | CSCuz27177 | Title: | "no cdp enable" config missing from VSL interfaces | |
Status: | Open | |
Severity: | 4 Minor | Description: | Symptom:"no cdp enable" config is missing from VSL interfaces.
Conditions:4500 VSS running 3.6.0 or above.
This issue has been observed during two scenarios: 1. upgrading software to 3.6.0 or above while already in virtual mode. 2. After converting to virtual mode while running 3.6.0 or above. Workaround:None. More Info:CDP packets are sent across VSL links, but do not appear to cause a problem.
| |
Last Modified: | 02-MAY-2016 | |
Known Affected Releases: | 3.8(0) | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | New | Bug Id: | CSCuz73474 | Title: | IP Source Guard pvlan support on trunk ports | |
Status: | Open | |
Severity: | 6 Enhancement | Description: | Symptom: Currently IP Source Guard is supported on pvlan host ports only. This is enhancement request to support also trunk ports with pvlans.
Conditions: IP Source Guard is configured on a trunk port with pvlans.
Workaround: None
Further Problem Description:
| |
Last Modified: | 19-MAY-2016 | |
Known Affected Releases: | 15.2(4)E1 | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | New | Bug Id: | CSCuz74872 | Title: | 4500 OBFL 'reset reason' should be more human readable | |
Status: | Open | |
Severity: | 6 Enhancement | Description: | Symptom: 4500 OBFL 'reset reason' should be more human readable
4500#show logging onboard uptime detail -------------------------------------------------------------------------------- UPTIME SUMMARY INFORMATION -------------------------------------------------------------------------------- First customer power on : 12/21/2013 12:37:15 Total uptime : 0 years 13 weeks 0 days 23 hours 25 minutes Total downtime : 2 years 6 weeks 2 days 3 hours 34 minutes Number of resets : 531 Number of slot changes : 5 Current reset reason : 0x0 <-----------------
Conditions: Reset reason is vague regarding a power cycle/power outage or a manual reload command.
Workaround:
Further Problem Description:
| |
Last Modified: | 28-MAY-2016 | |
Known Affected Releases: | 15.2(2)E3 | |
Known Fixed Releases: | | |
|
| |
|