Known Bugs - Prime Data Center Network Manager
| | |
Alert Type: | Updated * | Bug Id: | CSCuu06719 | Title: | Profile re-apply between universal and individual profiles does not work | |
Status: | Fixed | |
Severity: | 2 Severe | Description: | Symptom: Profile re-apply between universal and individual profiles does not work
Conditions: when a profile refresh is triggered from DCNM between universal and individual profiles it messes up the auto-config on the switch. Vlan and SVI get removed and profile goes into wait state. After this even if you use clear fabric database, upon the next auto-config trigger with universal profile the vlan goes into err-disabled state on the MCT
Workaround: only way to fix this is switch reload
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(0)N1(0.174) | |
Known Fixed Releases: * | 7.2(0.38)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5), 7.3(0)IB(0.67), 7.3(0)MMD(0.9), 7.3(0)OTT(0.30), 7.3(0)PDB(0.32) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCus76975 | Title: | DCNM auto-config profile name containing _space_ causes switch to reload | |
Status: | Fixed | |
Severity: | 2 Severe | Description: | Symptom: Reload on device when a profile with a space in the name is applied to the device via auto configuration.
Conditions: Profile created in DCNM for auto-config has a space in it.
Workaround: Make sure that the profile name does not contain a space. Pre-packaged profiles do not have this issue, custom-generated profiles should adhere this naming convention.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1) | |
Known Fixed Releases: * | 6.2(13)FM(0.54), 6.2(13)GS(0.15), 6.2(13.1)S0, 7.1(1.46)S0, 7.1(1.62)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)FM(0.4) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCus59551 | Title: | Template cannot be imported if properties is defined | |
Status: | Fixed | |
Severity: | 2 Severe | Description: | Symptom: Config template feature in web client does not allow to edit or save while importing a template
Conditions: When a template has the attribute "published" is set to true, and imported edit/save options are not available.
Workaround: Open the template in a text editor and the value for the attribute "published" to false.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1)S19 | |
Known Fixed Releases: * | 6.2(11.4)S0, 6.2(13)FM(0.33), 6.2(13)GS(0.13), 7.1(1.25)S0, 7.1(1.36)S0, 7.2(0)FM(0.2), 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuu75865 | Title: | Add global vlan profile subtype | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: Changes made to Network based on Global-Vlan-Profile (no segment ID) are not refreshed on switches
Conditions: Network created with a copy of "defaultNetworkUniversalTfGblVlanProfile" e.g. "defaultNetworkUniversalTfGblVlanProfile2"
Segment ID is configured but not used in profile.
Workaround: Rename the profile to end with 'GblVlanProfile' (case-insensitive), e.g. 'customizedGblVlanProfile'. The network refresh will then use VLAN ID instead of Segment ID for customized global VLAN profile.
Further Problem Description: This bug will support fully customized Global-Vlan-Profile names, as the trigger for refreshment is based on the profile subtype
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(0.39) | |
Known Fixed Releases: * | 7.2(1.22)S0, 7.2(1.23)S0, 7.3(0)D1(0.140), 7.3(0)DX(0.25), 7.3(0)GLF(0.25), 7.3(0)IB(0.122), 7.3(0)OTT(0.73), 7.3(0)PDB(0.102), 7.3(0)RTG(0.115), 7.3(0)SC(0.14) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCut48826 | Title: | Notify Border Leaf option on BL/ER pairing is cleared in remote DB case | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: "Notify Border Leaf when relevant partitions are changed" checkbox is always cleared and the leafs do not get their configuration updated.
Conditions: Happens when DCNM is configured with Oracle DB and partitions are extended.
Workaround: 'Manually run cli "fabric database auto-pull dci vrf VFRName node-id borderLeafIP peer-id edgeRouterIP" on the border leafs.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1.81) | |
Known Fixed Releases: * | 6.2(13)FM(0.54), 6.2(13)GS(0.15), 6.2(13.1)S0, 7.1(1.91)S0, 7.2(0.5)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)FM(0.4) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCub00716 | Title: | DCNM: TLS1.0/SSL3.0 Information Disclosure Vulnerability (CVE-2011-3389) | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: Cisco DCNM includes a version of OpenSSL that is affected by the vulnerabilities identified by the following Common Vulnerability and Exposures (CVE) IDs:
CVE-2011-3389 and CVE-2008-5161 This bug was opened to address the potential impact on this product.
Conditions: Device with default configuration.
Workaround: Not currently available.
Further Problem Description: Additional details about the vulnerabilities listed above can be found at http://cve.mitre.org/cve/cve.html PSIRT Evaluation: The Cisco PSIRT has assigned this bug the following CVSS version 2 score. The Base and Temporal CVSS scores as of the time of evaluation are 4.3/3.9: http://tools.cisco.com/security/center/cvssCalculator.x?vector=AV:N/AC:M/Au:N/C:P/I:N/A:N/E:POC/RL:U/RC:C&version=2.0 CVE ID CVE-2011-3389 and CVE-2008-5161has been assigned to document this issue. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
| |
Last Modified: | 20-DEC-2015 | |
Known Affected Releases: | 5.2(2c), 6.1(2), 6.2(3) | |
Known Fixed Releases: * | 6.2(11)FI(0.8), 6.2(11)S2, 6.2(11.1)S0, 6.2(13)FM(0.13), 6.2(13)GS(0.13), 6.2(5)S32, 6.3(0.165)S0, 6.3(0.74)S0, 6.3(1)S5, 6.3(1.3)S0 | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCus40622 | Title: | DCNM:Template job fails when there is undefined symbol in response | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: Config template shows job status as failed
Conditions: When a config template has the command 'copy r s' in it, the out put response contains the symbol '%'. This is considered as failure response and the commands are rolled back if the rollback option is enabled.
Workaround: To avoid marking the 'copy r s' response as failure, add the text "Copy complete" in a new line in the file /dcnm/data/templates/skip-error-patterns.txt. And restart the DCNM Services.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1)S19, 7.1(1.113) | |
Known Fixed Releases: * | 6.2(11.4)S0, 6.2(13)FM(0.33), 6.2(13)GS(0.13), 7.1(1.36)S0, 7.2(0)FM(0.2), 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuu02144 | Title: | DCNM: parameter input validation for border-RT field | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: In DFA auto-configuration, since the introduction of the universal profile, the network operator can optional add the value include_borderLeafRt, as example in the vrf-common-universal profile. When the network operator dont follow the exact required field notification with ASN:RT, then NX-OS will fail to configure the import route-target, this leads to a missing import of the default route originated from the borderleaf.
Conditions: When the network operator don't follow the exact required field notification with ASN:RT.
Workaround: The network operator need to update the network with the exact required field notification with ASN:RT.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1) | |
Known Fixed Releases: * | 7.2(0.44)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5), 7.3(0)IB(0.67), 7.3(0)MMD(0.9), 7.3(0)OTT(0.30), 7.3(0)PDB(0.32) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCur96084 | Title: | N5K-56XX devices are not listed in config template | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: When the templates supported platform is N5600, no N56** device types are listed for config delivery
Conditions: N56** device types are discovered and managed
Workaround: Add N5500 to the templates supported platform and save the template. Now select the template and try creating a config delivery job in the web client, the N56** devices should be available for selection.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(0.46) | |
Known Fixed Releases: * | 6.2(11.4)S0, 6.2(13)FM(0.33), 6.2(13)GS(0.13), 7.1(0.207)S0, 7.2(0)FM(0.2), 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuw16938 | Title: | N9K:7.0(3)l2: DCNM PC/VLAN/Interface configuration fails (XML netconf) | |
Status: * | Other | |
Severity: * | 3 Moderate | Description: | Symptom: Configuration of features VLAN, Port Channel, Interface using LAN Client for the N9K/N3K devices running with NX-OS version 7.0(3)l2 fails.
Conditions: Device fails to handle XML Set request sent from DCNM. XML/Netconf on the device is failing with exception
Workaround: Alternate option to use CLI. Templates can be used to configure these features on the device or manual CLI configuration.
Further Problem Description:
| |
Last Modified: | 23-DEC-2015 | |
Known Affected Releases: | 7.2(1.67) | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCur95202 | Title: | Cannot import template definition | |
Status: | Fixed | |
Severity: | 3 Moderate | Description: | Symptom: Imported template are grayed out
Conditions: Config->Delivery->Template->Select(predefined template)->Export
Config->Delivery->Template->Import
Workaround: After exporting the older template., open the file and remove all the lines that appear before ##template variables
then import it into DCNM.
Also, after import, please select the appropriate device types for this template and for POAP templates, select the POAP and the publish flags, so it can be used in the POAP flow.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(0)RTG(0.4) | |
Known Fixed Releases: * | 6.2(11.4)S0, 6.2(13)FM(0.33), 6.2(13)GS(0.13), 7.1(0.207)S0, 7.2(0)FM(0.2), 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuw18084 | Title: | Same name Partition Delete/Readd Fails already existing | |
Status: | Fixed | |
Severity: | 4 Minor | Description: | Symptom: DCNM Unified Fabric install, where delete and readd of the same named partition fails with already existing error.
Conditions: DCNM 7.2(1) OVA Unified install, can not readd same Partition name after delete, fails with already exists. In WebUI Config > Fabric> Auto-Configuration > Organizations > Partition(delete)(add)
Workaround: Clear browser cache or restart browser, or restart DCNM.
Further Problem Description: Note - same name for Partition if the trigger.
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(1), 7.2(1.67) | |
Known Fixed Releases: * | 7.2(1.81)S0, 7.3(0)D1(0.140), 7.3(0)DX(0.25), 7.3(0)GLF(0.25), 7.3(0)IB(0.122), 7.3(0)OTT(0.73), 7.3(0)PDB(0.102), 7.3(0)RTG(0.115), 7.3(0)SC(0.14), 7.3(0)ZD(0.155) | |
|
| | | | |
Alert Type: | New | Bug Id: | CSCux46475 | Title: | enum in @(IsMandatory=false) MACRO doesn't work with DCNM CLI templates | |
Status: | Open | |
Severity: | 4 Minor | Description: | Symptom: POAP template enum doesn't work with CLI template.
ex:@(IsMandatory=false, Enum="shut, no shut", DisplayName="shut or no shut", Description="shut or no shut")
enum doesn't work when use it in CLI template
but the following way works, enum ADMIN_STATE { validValues = shutdown, no shutdown; };
Conditions: DCNM CLI templates
Workaround: do not use enum part of @(IsMandatory=false) macro.
use enum seprately,
enum ADMIN_STATE { validValues = shutdown, no shutdown; };
Further Problem Description: | |
Last Modified: | 08-DEC-2015 | |
Known Affected Releases: | 7.2(2)ZN(99.9) | |
Known Fixed Releases: | | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuu30946 | Title: | DCNM - Empty Intf Descr for Eth ports | |
Status: | Fixed | |
Severity: | 4 Minor | Description: | Symptom: In some situations, the DCNM web GUI will not display the interface description for Ethernet interfaces despite displaying the descriptions for FC interfaces.
Conditions: DCNM 7.1.1
Workaround: Use the Device Manager client to view the intf descriptions instead.
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1) | |
Known Fixed Releases: * | 7.2(0.37)S0, 7.2(0.38)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31), 7.3(0)DX(0.16), 7.3(0)EG(0.3), 7.3(0)HM(0.5), 7.3(0)IB(0.67), 7.3(0)MMD(0.9), 7.3(0)OTT(0.30) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuv49707 | Title: | mouse over for N7k does not work on whole icon | |
Status: | Fixed | |
Severity: | 5 Cosmetic | Description: | Symptom: mouse over for N7k in standard Topology does not work on whole icon. It is required to mouse over on certain small spots of the N7k to get additional information being showed up
Conditions: new install with default values
Workaround: none
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.1(1), 7.1(2), 7.2(1) | |
Known Fixed Releases: * | 7.2(1.64)S0, 7.3(0)D1(0.140), 7.3(0)DX(0.25), 7.3(0)GLF(0.25), 7.3(0)IB(0.122), 7.3(0)OTT(0.73), 7.3(0)PDB(0.102), 7.3(0)RTG(0.115), 7.3(0)SC(0.14), 7.3(0)ZD(0.155) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuv49627 | Title: | Pull down in POAP Template look inactive | |
Status: | Fixed | |
Severity: | 5 Cosmetic | Description: | Symptom: Pull down fields in POAP Template look inactive as text is shown light grey (Template Parameters). Text should be more solid black
Conditions: new install with default values
Workaround: none
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(1) | |
Known Fixed Releases: * | 7.2(1.68)S0, 7.3(0)D1(0.140), 7.3(0)DX(0.25), 7.3(0)GLF(0.25), 7.3(0)IB(0.122), 7.3(0)OTT(0.73), 7.3(0)PDB(0.102), 7.3(0)RTG(0.115), 7.3(0)SC(0.14), 7.3(0)ZD(0.155) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCup27841 | Title: | vcenter 5.5 registration fails due to improper certs | |
Status: | Fixed | |
Severity: | 6 Enhancement | Description: | Symptom: vcenter 5.5 registration fails in 6.3.1 due to checksum on certs. need an option to ignore certs
Conditions: Wireshark capture will show the VCenter certificate error.
Workaround: Apply a valid certificate
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 6.3(1) | |
Known Fixed Releases: * | 6.2(10)CR(0.14), 6.2(10.7)S0, 6.2(11)FM(0.7), 6.2(12)BFP(0.13), 6.2(12)FM(0.5), 6.2(8)TS(0.28), 6.3(2)S47, 7.1(0.39)S0, 7.3(0)D1(0.71), 7.3(0)DHB(0.31) | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuv49839 | Title: | Partition ID should be configurable | |
Status: | Fixed | |
Severity: | 6 Enhancement | Description: | Symptom: Partition ID should be configurable and go along with the VRF/VLAN/L3VNI pool requirement
Conditions: new install with default values
Workaround: none
Further Problem Description:
| |
Last Modified: | 19-DEC-2015 | |
Known Affected Releases: | 7.2(1) | |
Known Fixed Releases: * | 7.2(2.14)S0, 7.2(2.38)S0, 7.2(2.40)S0, 7.2(2.52)S0, 7.3(0)D1(0.140), 7.3(0)D1(0.156), 7.3(0)D1(0.179), 7.3(0)DX(0.25), 7.3(0)GLF(0.25), 7.3(0)IB(0.122) | |
|
| |
|