Alert Type: | New |
Bug Id: | CSCux42903 | Title: | ASR9912: Duplicate alias keys in PortData causing mess in LAG inventory |
|
Status: | Open |
|
Severity: | 2 Severe |
Description: | Symptom: ASR9912 VNE physical command parser creates duplicate alias keys for multiple PortData IRDs.
Conditions: ASR9912 with CPAK interfaces
Workaround: There is no workaround for this defect
Further Problem Description: |
|
Last Modified: | 05-DEC-2015 |
|
Known Affected Releases: | 4.2(2)DP1511.0.742 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux58094 | Title: | NexusC7706 multi-chassis VNE: missing line cards in the main chassis |
|
Status: | Open |
|
Severity: | 2 Severe |
Description: * | Symptom: While modeling NexusC7706 multi-chassis switch, Version 6.2(10), it was noticed that VNE erroneously models physical inventory of the main chassis: Missing all the cards, SFP transceivers are modeled as modules.
Conditions: NexusC7706 multi-chassis switch, Version 6.2(10)
Workaround: Not known
Further Problem Description:
|
|
Last Modified: | 18-DEC-2015 |
|
Known Affected Releases: | 4.2(0X)DP1511.0.742 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw74181 | Title: | NCCM:Tar file activation failed when select activation at scheduled time |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Activation of image failed.
Conditions: When using tar file and selecting activation for future date.
Workaround: 1. Distribute the image (tar) using the CCM GUI and select future date for activation. 2. Cancel the activation job manually. 3. Activate/Commit using Command Manager script during maintenance window.
Further Problem Description:
|
|
Last Modified: | 21-DEC-2015 |
|
Known Affected Releases: * | 4.2(2.0)PP2 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv37922 | Title: | Some MLPPP properties show wrong Name, Group, Active Link |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Properties window for some of the MLPPP interfaces show properties (Name, Group, Active Links, etc.) of another MLPPP interface.
Conditions: Configuration of multiple Multilink interfaces on ASR9K device.
Workaround: none
Further Problem Description:
|
|
Last Modified: | 08-DEC-2015 |
|
Known Affected Releases: * | 4.2(1)DP1511.0.742 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux24698 | Title: | UCS6200 VNE missing fan modules in FabricInterconnect chassis |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Physical inventory of both FabricInterconnect chassis of UCS6200 is missing fan modules.
Conditions: UCS6200
Workaround: Not known
Further Problem Description:
|
|
Last Modified: | 22-DEC-2015 |
|
Known Affected Releases: * | 4.2(0X)DP1511.0.742, 4.2(2)DP1509.0.702 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux55031 | Title: | AVM crashes when DP 1509 is applied and ISIS is modelled. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: AVM Crashes
Conditions: AVM set at 1024 MB has a single VNE is crashing after 6 mins of starting up. Last command executed was "show ip cef detail", which returned ~22,00,000 lines on the device.
Workaround: 1. Disable ISIS from the IPCore scheme. OR 2. Run AVM with 2048 MB.
Further Problem Description:
|
|
Last Modified: | 28-DEC-2015 |
|
Known Affected Releases: | 4.1(0X)DP1509.0.702 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv37880 | Title: | PN - PortAlias variable missing in Command Builder for Port Status |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Default CB scripts for control port status on interfaces are not working for some VNE types due to missing $PortAlias$ variable.
Conditions: None
Workaround: Manually modify the default scripts to use $PortNumber$ variable instead.
Further Problem Description:
|
|
Last Modified: | 22-DEC-2015 |
|
Known Affected Releases: * | 4.2(1)DP1601.0.791, 4.2(2)DP1601.0.791 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuq88548 | Title: | 9K, 9904 :Some execution of out of the box command stuck |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: When run Run "Create SyncE Clock Global" out of the box command with some parameters, The command stuck
The issue was seeing on ASR9006 and on ASR9904
Conditions:
Workaround:
Further Problem Description: |
|
Last Modified: | 23-DEC-2015 |
|
Known Affected Releases: * | 4.1(0X)DP1601.0.751 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv87419 | Title: | NCCM return failure on QVPC configuration restore but it success |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: NCCM return failure on QVPC configuration restore but it success
Conditions: 1. Model QVPC 2. Restore configuration via NCCM
Workaround:
Further Problem Description:
|
|
Last Modified: | 23-DEC-2015 |
|
Known Affected Releases: * | 4.2(0.1)PP4, 4.2(0.1)PP5, 4.2(2.0)PP3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw71191 | Title: | CCM Compliance Audit does not allow _ (underscore) in commands |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: CCM compliance audit, command fails due to command missing _ (underscore).
Conditions: New policy created with rule having condition scope device command output and command having _ underscore in them.
Workaround: none.
Further Problem Description:
|
|
Last Modified: | 24-DEC-2015 |
|
Known Affected Releases: | 4.2(2.662) |
|
Known Fixed Releases: * | 4.2(0.1)PP5, 4.2(2.0)PP3 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu27480 | Title: | NCCM - config restoration fail in device banner on 6500 device series |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Configuration restore on 6500 device fails when banner exist
Conditions: Restore config with multi banner config on 6500 as below ! privilege exec level 6 show running-config privilege exec level 6 copy banner incoming ^Cmytet^C banner login ^Ctest^C banner motd ^C Cisco Systems, NMTG ^C !
Workaround: Edit the backup configuration manually and re-enter the same config and restore the edited configuration
Further Problem Description:
|
|
Last Modified: | 24-DEC-2015 |
|
Known Affected Releases: | 4.1(0.1)PP0 |
|
Known Fixed Releases: * | 4.1(0.1)PP1, 4.1(0.1)PP2, 4.2(0.1)PP4, 4.2(1.0)PP1, 4.2(2.0)PP3 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCux63737 | Title: | Nexus9332 VNE: add support for %FEX-2-NOHMS_ENV_FEX_OFFLINE syslogs |
|
Status: | Open |
|
Severity: | 6 Enhancement |
Description: | Symptom: Nexus9332 multi-chassis switch VNE does not recognize FEX chassis OFFLINE and ONLINE syslog messages and therefore does not develop chassis disconnected/connected service alarms.
Conditions: FEX chassis reload on Nexus9332.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 22-DEC-2015 |
|
Known Affected Releases: | 4.2(0X)DP1511.0.742 |
|
Known Fixed Releases: | |
|
|
| |