Known Bugs - ME 1200 Series Carrier Ethernet Access Devices
| | |
Alert Type: | Updated * | Bug Id: | CSCut59692 | Title: | ME1200 Interface Config Returned to Default After Reload | |
Status: | Fixed | |
Severity: | 1 Catastrophic | Description: | Symptom: Interfaces on the ME1200 switch platform are returned to their default configuration after a reload or power outage
Conditions: Only occurs in standalone mode Observed in all current versions of IOS on this platform.
Workaround: None
Further Problem Description:
| |
Last Modified: | 17-DEC-2015 | |
Known Affected Releases: | 15.4(2)S, 15.4(3)S, 15.5(1)S | |
Known Fixed Releases: * | 15.4(3)S3.3, 15.4(3)S4, 15.5(1)S2.1, 15.5(1)S2.15, 15.5(1)S3, 15.5(2)S0.6, 15.5(2)S1, 15.5(2)SN, 15.5(2.21)S0.12, 15.5(2.21)S0.6 | |
|
| | | | |
Alert Type: | Updated * | Bug Id: | CSCuw70347 | Title: | ME1200 device software version is not updated | |
Status: | Fixed | |
Severity: | 2 Severe | Description: | Symptom: After upload the image(15.5(3)SN) in the ME1200 device, software version \ not updated, it is showing as a 15.5-2.SN. This is impacting Prime Networking application as version field is not updated causing confusion to customer.
Conditions: On UCS NID controller running 15.5(3)SN
Workaround: none
Further Problem Description:
| |
Last Modified: | 30-DEC-2015 | |
Known Affected Releases: | 15.5(3) | |
Known Fixed Releases: * | 15.5(3)S1.5 | |
|
| |
|