Alert Type: | Updated * |
Bug Id: | CSCed42822 | Title: | SNMP relay IP and community string not getting updated in NE expl |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: In Network Explorer->Netowrk->SNMP tab, If we delete all Relay IP Address or Community Names , the updates for Relay B and Relay C are not propogated to CTM
Conditions: When we delete Relay B and Relay C community Names or IP Addresses also.
Workaround:None
Resolution:Future releases
Reproducibility(%):100% |
|
Last Modified: | 22-OCT-2015 |
|
Known Affected Releases: * | 4.6(0.498), 5.0 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCea13560 | Title: | For some Electrical path parametrs TCAs were not gen. by E1 card |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: CTC does not generate TCAs for electrical path EB-P thresholds on E1-42 cards.
Conditions: For E1-42 cards, the EB-P thresholds are the same as CV-P thresholds. The NE generates a TCA against the CV-P threshold, but the mapping of EB-P to CV-P is not done.
There is no known workaround.
|
|
Last Modified: | 11-OCT-2015 |
|
Known Affected Releases: * | 4.0, 4.1, 4.6 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCea15501 | Title: | For the warnings coming on port-1 of STM1E card the E4 object is |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: For an STM1E-12 card, the Alarm Browser shows an E4 card instead of STM1E in the Affected Object field.
Conditions: The Affected Object field shows an E4 card instead of STM1E for the following warning alarms or alarm conditions on ports 1 to 8 on an STM1E-12 card:
- Loopback terminal - Loopback facility - BER thresholds - Alarms suppressed for maintenance
Workaround: None. |
|
Last Modified: | 11-OCT-2015 |
|
Known Affected Releases: | 4.6, 5.0, 6.0 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur54616 | Title: * | TACACS authentication fails if ICMP or RST SYN packets are blocked |
|
Status: | Open |
|
Severity: * | 3 Moderate |
Description: | Symptom: CPO Client authentication through TACACS fails
Conditions: TACACS authentication configured on CPO
Workaround: None
Further Problem Description:
|
|
Last Modified: | 28-OCT-2015 |
|
Known Affected Releases: | 10.0(0.0.309), 10.0(2), 10.3(0.0.1), 9.8 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCec48260 | Title: | PM Buckets missed/show correct stats when time chng on NE |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: In rare cases, CTM does not collect performance monitoring data on an ONS 15327, ONS 15454 SONET, or ONS 15454 SDH NE for a period of time and begins collecting this data again.
Conditions: When the NE time is changed on an ONS 15327, ONS 15454 SONET, or ONS 15454 SDH NE to a time in the past, CTM will not collect performance monitoring data for time periods that have already been collected under the previous NE time setting. This problem occurs whether or not robust PM collection is enabled.
Workaround: None.
|
|
Last Modified: | 18-OCT-2015 |
|
Known Affected Releases: | 4.6, 5.0 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCed12606 | Title: | Pwr: Battery Fail alarm shows as MN though alarm profile is MJ |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: Battery Failure alarm is reported as MN in CTM alarm browser even though the Alarm profile is set to MJ for this alarm
Conditions:The issue typically occurs with the following steps Open alarm browser. Look for battery failure alarm Open Alarm Profile table & see PWR: BAT-Fail alarm is set for MJ
Workaround:None
|
|
Last Modified: | 20-OCT-2015 |
|
Known Affected Releases: * | 4.6(0.433), 5.0 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCud79214 | Title: | No message shown when attempting to access CPO with wrong credentials |
|
Status: | Open |
|
Severity: | 4 Minor |
Description: | Symptom: No warniing message is shown when user attempts to login into Prime Optical with wrong credential.
Conditions: User attemps to login to Prime Optical portal with wrong user or password.
Workaround: none |
|
Last Modified: | 08-OCT-2015 |
|
Known Affected Releases: * | 10.0(0.0.1), 10.0(2.0.1), 10.3(0.0.1), 10.5(0), 9.6(0.128), 9.6(3.1), 9.8(0.0.1) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCeb71477 | Title: | Physical location field was not showing port name in alarm:some c |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: * | Symptom: For Carrier Loss on LAN Alarm on ML1000 and ML100T-2 cards the Port Names are not seen on CTM.
Condition: Port Names should be set on the Ports of the ML1000 and ML100T-2 cards.
Workaround: None
Expected Resolution: Next CTM release |
|
Last Modified: | 15-OCT-2015 |
|
Known Affected Releases: | 4.1(0.450), 4.6, 5.0 |
|
Known Fixed Releases: | |
|
|
| |