Cisco Blog » The Platform

2015年11月1日星期日

Cisco Notification Alert -Cisco Optical - Prime Optical-01-Nov-2015 17:49 GMT

 

 

 

 

 

 

 


Security Advisories & Responses - Prime Optical

Title:
Multiple Vulnerabilities in OpenSSL (June 2015) Affecting Cisco Products
Description:

On June 11, 2015, the OpenSSL Project released a security advisory detailing six distinct vulnerabilities, and another fix that provides hardening protections against exploits as described in the Logjam research.

Multiple Cisco products incorporate a version of the OpenSSL package affected by one or more vulnerabilities that could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition or corrupt portions of OpenSSL process memory.

This advisory will be updated as additional information becomes available.

Cisco will release software updates that address these vulnerabilities.

Workarounds that mitigate these vulnerabilities may be available.

This advisory is available at the following link:
http://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20150612-openssl

Date:
16-OCT-2015

Find additional information in Cisco Security Advisories & Responses

Known Bugs - Prime Optical

Alert Type:
Updated *
Bug Id:
CSCed42822
Title:
SNMP relay IP and community string not getting updated in NE expl
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom: In Network Explorer->Netowrk->SNMP tab, If we delete all Relay IP Address
or Community Names , the updates for Relay B and Relay C are not propogated to CTM

Conditions: When we delete Relay B and Relay C community Names or IP Addresses also.

Workaround:None

Resolution:Future releases

Reproducibility(%):100%

Last Modified:
22-OCT-2015
Known Affected Releases: *
4.6(0.498), 5.0
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCea13560
Title:
For some Electrical path parametrs TCAs were not gen. by E1 card
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom: CTC does not generate TCAs for electrical path EB-P thresholds on
E1-42 cards.

Conditions: For E1-42 cards, the EB-P thresholds are the same as CV-P
thresholds. The NE generates a TCA against the CV-P threshold, but the mapping
of EB-P to CV-P is not done.

There is no known workaround.


Last Modified:
11-OCT-2015
Known Affected Releases: *
4.0, 4.1, 4.6
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCea15501
Title:
For the warnings coming on port-1 of STM1E card the E4 object is
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom: For an STM1E-12 card, the Alarm Browser shows an E4 card instead of
STM1E in the Affected Object field.

Conditions: The Affected Object field shows an E4 card instead of STM1E for the
following warning alarms or alarm conditions on ports 1 to 8 on an STM1E-12 card:

- Loopback terminal
- Loopback facility
- BER thresholds
- Alarms suppressed for maintenance

Workaround: None.

Last Modified:
11-OCT-2015
Known Affected Releases:
4.6, 5.0, 6.0
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCur54616
Title: *
TACACS authentication fails if ICMP or RST SYN packets are blocked
Status:
Open
Severity: *
3 Moderate
Description:

Symptom:
CPO Client authentication through TACACS fails

Conditions:
TACACS authentication configured on CPO

Workaround:
None

Further Problem Description:

Last Modified:
28-OCT-2015
Known Affected Releases:
10.0(0.0.309), 10.0(2), 10.3(0.0.1), 9.8
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCec48260
Title:
PM Buckets missed/show correct stats when time chng on NE
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
In rare cases, CTM does not collect performance monitoring data on an ONS
15327, ONS 15454 SONET, or ONS 15454 SDH NE for a period of time and begins
collecting this data again.

Conditions:
When the NE time is changed on an ONS 15327, ONS 15454 SONET, or ONS 15454 SDH
NE to a time in the past, CTM will not collect performance monitoring data for
time periods that have already been collected under the previous NE time
setting. This problem occurs whether or not robust PM collection is enabled.

Workaround:
None.

Last Modified:
18-OCT-2015
Known Affected Releases:
4.6, 5.0
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCed12606
Title:
Pwr: Battery Fail alarm shows as MN though alarm profile is MJ
Status:
Fixed
Severity:
3 Moderate
Description: *

Symptom:
Battery Failure alarm is reported as MN in CTM alarm browser even
though the Alarm profile is set to MJ for this alarm

Conditions:The issue typically occurs with the following steps
Open alarm browser. Look for battery failure alarm
Open Alarm Profile table & see PWR: BAT-Fail alarm is set for MJ

Workaround:None

Last Modified:
20-OCT-2015
Known Affected Releases: *
4.6(0.433), 5.0
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCud79214
Title:
No message shown when attempting to access CPO with wrong credentials
Status:
Open
Severity:
4 Minor
Description:

Symptom: No warniing message is shown when user attempts to login into Prime Optical with wrong credential.

Conditions: User attemps to login to Prime Optical portal with wrong user or password.

Workaround: none

Last Modified:
08-OCT-2015
Known Affected Releases: *
10.0(0.0.1), 10.0(2.0.1), 10.3(0.0.1), 10.5(0), 9.6(0.128), 9.6(3.1), 9.8(0.0.1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCeb71477
Title:
Physical location field was not showing port name in alarm:some c
Status:
Fixed
Severity:
4 Minor
Description: *

Symptom:
For Carrier Loss on LAN Alarm on ML1000 and ML100T-2 cards the Port Names
are not seen on CTM.

Condition:
Port Names should be set on the Ports of the ML1000 and ML100T-2 cards.

Workaround:
None

Expected Resolution:
Next CTM release

Last Modified: