Cisco Blog » The Platform

2015年10月1日星期四

Cisco Notification Alert -Prime - Cisco Prime Network-01-Oct-2015 16:50 GMT

 

 

 

 

 

 

 


End-of-Sale and End-of-Life Announcements - Prime Network

Title:
End-of-Sale and End-of-Life Announcement for the Cisco Prime Network 4.1
Description:

Cisco announces the end-of-sale and end-of-life dates for the Cisco Prime Network 4.1. The last day to order the affected product(s) is March 10, 2016. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table 1 of the EoL bulletin. Table 1 describes the end-of-life milestones, definitions, and dates for the affected product(s). Table 2 lists the product part numbers affected by this announcement. For customers with active and paid service and support contracts, support will be available under the terms and conditions of customers' service contract. Click here for the French Version of this Bulletin.

Date:
11-SEP-2015

Find additional information in End-of-Sale and End-of-Life Products

Software Updates for Prime Network

Product Name:
Prime Network 4.2
Software Type:
Prime Network VNE Drivers
Release Version:
4.2-DP1509
Alert Type:
New File
File Name:
PrimeNetwork-4.2-DP1509.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.2.0.1.4,4.2.0.1.3,4.2.0.1.2,4.2.0.1.1,4.2.0.1.0

File Release Date:
30-SEP-2015
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2.1
Software Type:
Prime Network VNE Drivers
Release Version:
4.2.1-DP1509
Alert Type:
New File
File Name:
PrimeNetwork-4.2.1-DP1509.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.2.1.0.1

File Release Date:
30-SEP-2015
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2.2
Software Type:
Prime Network VNE Drivers
Release Version:
4.2.2-DP1508
Alert Type:
New File
File Name:
PrimeNetwork-4.2.2-DP1508.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.2.2.0.1

File Release Date:
02-SEP-2015

Software Updates for Prime Network

Product Name:
Prime Network 4.2.2
Software Type:
Prime Network VNE Drivers
Release Version:
4.2.2-DP1509
Alert Type:
New File
File Name:
PrimeNetwork-4.2.2-DP1509.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.2.2.0.1

File Release Date:
30-SEP-2015
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2
Software Type:
Prime Network Patches
Release Version:
4.2.0.1.4
Alert Type:
New File
File Name:
Prime_Network4.2.0.1.4.zip
File Description:

Prime Network 4.2 Service Patch 1 Point Patch 4

File Release Date:
03-SEP-2015
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.2.2
Software Type:
Prime Network Patches
Release Version:
4.2.2.0.1
Alert Type:
New File
File Name:
Prime_Network4.2.2.0.1.zip
File Description:

Prime Network 4.2.2 Point Patch 1

File Release Date:
01-SEP-2015
Find additional information in Software Downloads index.

Software Updates for Prime Network

Product Name:
Prime Network 4.1
Software Type:
Prime Network VNE Drivers
Release Version:
4.1-DP1509
Alert Type:
New File
File Name:
PrimeNetwork-4.1-DP1509.tar
File Description:

VNE Device Package for Cisco Prime Network versions 4.1.0.1.2,4.1.0.1.1,4.1.0.1.0, 4.1.0.0.4, 4.1.0.0.3, 4.1.0.0.2, 4.1.0.0.1

File Release Date:
30-SEP-2015
Find additional information in Software Downloads index.

Known Bugs - Prime Network

Alert Type:
New
Bug Id:
CSCuv85452
Title:
VNE is not modeled using SSH
Status:
Fixed
Severity:
2 Severe
Description:



Symptom:
VNE is not modelling with SSH.

Conditions:
Model the device SSH v2.
Communication state is showing as Device Partially down i.e Telnet/SSH status is down

Workaround:
None

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(2.601)
Known Fixed Releases:
4.2(2.0)PP1
Alert Type:
Updated *
Bug Id:
CSCuu45704
Title:
Image Activation Fails with " image not present on Device"
Status:
Fixed
Severity:
2 Severe
Description:



Symptom:
Image Activation Fails with " image not present on Device"

Conditions:
While performing 9k Benchmarking for Activation operation, the Activation jobs are failing with " image not present on the Device, even though the image is present on the Device bootflash"

Steps :
1) )Install PN 4.2.1
2)Launch CCM Application with url 'https://172.18.79.14:8043/ccmweb/'
3)Schedule 4 Activation Jobs with 2250 Devices each.
4) Schedule the job with IOS by Image Flow, select image :Image asr1000rp1-adventerprisek9.03.09.01.S.153-2.S1.bin.
5) Verify the results.

Workaround:
When the Failed Device is scheduled for activation individually it is passing successfully.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(2), 4.2(2.612)
Known Fixed Releases: *
4.2(0.1)PP4, 4.2(2)
Alert Type:
Updated *
Bug Id:
CSCuv64507
Title:
ASR1K LACP LAG appear as Manual
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
ASR1K LACP LAG appear as Manual

Conditions:
1. Model ASR1K
2. Open Inventory -> Logical Inventory -> Ethernet Link Aggregation

Workaround:
NA

Further Problem Description:

Last Modified:
01-SEP-2015
Known Affected Releases: *
4.1(0X)DP1505.0.622, 4.2(0X)DP1507.0.671
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCum81307
Title:
Scale CRS VNE is contantly executing/expediting scale registrations
Status: *
Fixed
Severity:
3 Moderate
Description:

Symptom:
VNE consumes a lot of memory.

Conditions:
Scale CRS device with a lot of VRFs and a large LSE table.

Workaround:
no workarounds

Further Problem Description:

Last Modified:
29-SEP-2015
Known Affected Releases:
3.10(11)XDP1310.0.772, 4.0, 4.1, 4.2, 4.2(1), 4.2(2)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv54343
Title:
LFA alternative path removed event not correlated to card down and not c
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
LFA alternative path removed event not correlated to card down

Conditions:
1. Model ASR903
2. Card down ASR 903

Workaround:

Further Problem Description:

Last Modified:
01-SEP-2015
Known Affected Releases: *
4.1(0.1)PP2, 4.2(0.1)PP4
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv52774
Title:
The linkDown trap for VLAN trunk port is not associated with interface
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Catalyst 3550 VNE fails associate linkDown trap for Layer2 VLAN trunk port with corresponding interface.

Conditions:
Configuration of VLAN interface with no IP address assigned on Catalyst 3550.

Workaround:
Not known.

Further Problem Description:

Last Modified:
29-SEP-2015
Known Affected Releases:
4.1(0X)DP1505.0.622
Known Fixed Releases: *
4.1DP1509, 4.2(1)DP1509, 4.2(2)DP1509, 4.2DP1509
Alert Type:
Updated *
Bug Id:
CSCuu99423
Title:
Image distribute some times fails with NullpointerException
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Image distribute fails with NullPointerException

Conditions:
NA

Workaround:
Try distributing the image again

Further Problem Description:

Last Modified:
29-SEP-2015
Known Affected Releases:
4.2(1)DP1505.0.611
Known Fixed Releases: *
4.1DP1509, 4.2(1)DP1509, 4.2DP1509
Alert Type:
Updated *
Bug Id:
CSCuw37340
Title:
PW not modeled and Bridge has no info
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
no PW and no data under bridge

Conditions:
none

Workaround:
none

Further Problem Description:
none

Last Modified:
28-SEP-2015
Known Affected Releases:
4.2(1)DP1507.0.663
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuq99569
Title:
PWHE: No change in subinterface status even when VRF removed in far end.
Status:
Fixed
Severity:
3 Moderate
Description: *



Symptom:
PWHE: No change in the subinterface status even when the VRF is removed in the far end.

Conditions:
Noticed when VRF is removed in the far end.

Workaround:
Make the VRF interface down, check the syslogs, then the status will get changed.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
28-SEP-2015
Known Affected Releases:
4.2(0X)DP0.0.382, 4.2(2)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv82644
Title:
ASR9912 VNE: Port/card status is not updated in the tree-view
Status:
Open
Severity:
3 Moderate
Description: *

Symptom:
Network Vision fails update port and/or card status in the ASR9912 VNE inventory tree-view.

Conditions:
ASR9912 VNE

Workaround:
Although workaround is exist - reload of the inventory window - it is not acceptable for the end user.

Further Problem Description:
Further investigation showed that IManagedElement IMO contains multiple cyclic references, which considered to be the root cause of the external symptoms.

Last Modified:
16-SEP-2015
Known Affected Releases:
4.1(0X)DP1509.0.682, 4.2(0X)DP1507.0.671
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCui81411
Title:
Bridge table is not modeling Nexus 1000v.
Status: *
Terminated
Severity:
3 Moderate
Description:



Symptom:
Bridge table is not modeled for Nexus 1000v device.

Conditions:
Bridge table is not modeled for Nexus 1000v device when more than one VEM is learning the same MAC address.

Workaround:
NA

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
09-SEP-2015
Known Affected Releases:
4.1(0X)DP0.0.242, 4.2(2)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv57682
Title:
Path Tracer fails to find trace route for PW originated on ASR9K VNE
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
When the Path Tracer is initiated from a pseudo-wire endpoint at the ASR9K VNE, the path shows only local interface. When the same operation is performed from the ME3600 VNE, it works properly showing full trace route.

Conditions:
Initiating Path Tracer on pseudo-wire from endpoint on ASR9K VNE.

Workaround:
Not known

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(0.1)PP3
Known Fixed Releases: *
4.2(0.1)PP4
Alert Type:
New
Bug Id:
CSCus94180
Title:
Duplicate representation of EFPs associated to a pseudowire
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Add to Map-> Pseudowire, select a PW associated to an EFP, the same EFP is represented twice - one within the PW container and the other outside.

Conditions:
PW discovery and EVC discovery displays PWs attached to EFPs with the EFP represented twice.
Add to Map->PW or Add to Map->EVC and select one such PW attached to EFP to view this scenario

Workaround:
None

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(1)DP0.0.552, 4.2(2)DP1508.0.671
Known Fixed Releases:
4.2(2)DP1508
Alert Type:
New
Bug Id:
CSCuv51845
Title:
Image Distribution: Same device result is showing multiple times.
Status:
Fixed
Severity:
3 Moderate
Description:



Symptom:
Image Distribution: Same device result is showing multiple times on job result page, under successful column.

Conditions:
While executing on scale environment it occurs.

Workaround:
None.

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(2.662)
Known Fixed Releases:
4.2(2.0)PP1
Alert Type:
New
Bug Id:
CSCuw02666
Title:
Cancel option is not working for image distribution job that is running.
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
Cancel the Running Image Distribution Job happens after 5 to 10 minutes

Conditions:
After Scheduling the Image Distribution Job and cancel the Job

Workaround:
Need to wait for sometime (5 to 10 minutes) to cancel the job

Further Problem Description:

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(2.0)PP1
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv80763
Title:
QVPC syslogs description not clear and missing information
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
QVPC syslogs description not clear and missing information, include location that is to the ME.
Category and Nature are unknown.

The descriptions that are not clear are in card out operations and are:
Messaging error
General warning
New alarm
Syslogd err
clear alarm

Conditions:
1. Model QVPC device with standby card
2. Card out the standby Port Service Function card (Shutdown VM)

Workaround:

Further Problem Description:

Last Modified:
02-SEP-2015
Known Affected Releases: *
4.2(2)DP0.0.653
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCur83563
Title:
ISIS information in IOS XR is showing wrong data.
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
IPv4 Metric in ISIS information is showing wrong data.

Conditions:
On all IOS XR configured with ISIS.

Workaround:
NA

Further Problem Description:

Last Modified:
03-SEP-2015
Known Affected Releases:
4.1, 4.1(0.999), 4.2, 4.2(0.1)PP4, 4.2(1)
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuu36668
Title:
Asr901: Issues in IS-IS technology
Status:
Open
Severity:
3 Moderate
Description:



Symptom:
Issues:
1)Duplicate column 'IS Type' needs to be removed from PN421
2)IS Type column values needs to be populated in PN41 and PN42

Note: Values under this column are populating in PN40 and PN421

Conditions:
Steps To Reproduce:
1)Model Asr901 device
2)LI-->IS-IS

Expected Result:
1)Duplicate column needs to be removed
2)Values should be populated under IS Type column

Workaround:
Not Applicable

Further Problem Description:



(release notes added by addprefcs-org.ksh)

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(0.1)PP4
Known Fixed Releases: *
4.2(0.1)PP4, 4.2(2)
Alert Type:
Updated *
Bug Id:
CSCus77219
Title:
Link down due to card out between ASR9K IC port to satellite is not clea
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Have setup with 2 ASR9K and ring of 3 satellites
Ex:

A9K-CN-ABR1 - SAT 201 (active on ABR1) - SAT 202 (active on ABR1) -SAT 201 (active on ABR3) - A9904-CN-ABR3


And card down MOD80 card (On ABR1), the card that has the IC port.
Now card up the card.

"Link down due to card out" ticket between the IC port and the satellite that is connected to the IC port will not be cleaned.

The status of the Satellite port will be unknown and poll not will not solve the issue

Conditions:
1. Model ASR9K with 3 satellites on ring topology
2. Card down MOD80 card (The card that contain the IC port)
ex: RP/0/RSP0/CPU0:A9K6-CN-ABR1(admin-config)# hw-module shutdown location 0/1/CPU0
3. Card in the card

Workaround:
None

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(0.502), 4.2(1), 4.2(2)
Known Fixed Releases: *
4.2(0.1)PP4, 4.2(2)
Alert Type:
Updated *
Bug Id:
CSCus75143
Title:
ASR9K satellite down event is not correlate to link down
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
"Satellite down" event of satellite that is connected to IC port is not correlated to link down ticket that one of the ports is the IC ports

The satellite is part of satellite ring topology

Conditions:
1. Model 2 ASR9K with satellite ring topology
2. Shutdown IC port of one of the satellite (ex: 10.56.116.223 GE 0/1/1/9)

Workaround:
N/A

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(2), 4.2(2.552)
Known Fixed Releases: *
4.2(0.1)PP4, 4.2(2)
Alert Type:
Updated *
Bug Id:
CSCuv48843
Title:
SNMP reachability test param change doesnot affect the alarm development
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Change in number of SNMP reachability test retries before the alarm should be created does not affect the Device Unreachable alarm development interval - the alarm continues to be developed within 30-50 seconds.

Conditions:
Not specific

Workaround:
Not known

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.1(0.1)PP1
Known Fixed Releases: *
4.2(0.1)PP4
Alert Type:
Updated *
Bug Id:
CSCuu75507
Title:
ccm config edit comma followed by space introduces new line character
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
New line introduced in any field when there is a comma followed by space in any field during "Configuration Edit" operation in CCM UI.

Conditions:
Device configuration has any comments with comma followed by space and if the same config is edited in CCM.

Workaround:
do not follow the comma with a space in the comment.

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(0.999)
Known Fixed Releases: *
4.1(0.1)PP2, 4.2(0.1)PP4
Alert Type:
Updated *
Bug Id:
CSCur68162
Title:
CCM job/CB exe not work when "Ask for user creds" is en and device is wi
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
PN has the option give the user enter his own creds before execution of NCCM job/Command builder.

In case a device has the following sequance

Username:
Password:
> en
Password:
#

and the VNE is modeled via telnet and user will execute a job and add device creds (username and password), PN will use the selected creds and for the rest of the sequance PN will take it from VNE properties(right behavior).

In case VNE is modeled via SSH and user will execute a job and put device creds, PN will fail the job and the following error will appear in the AVM log

java.lang.IllegalArgumentException: cannot create a telnet login command where number of prompts is not the same as number of commands + 1


VNE that is modeled via SSH should act as VNE that is modeled via telnet.
Meaning it should use the selected username/password and take the rest of the sequance from the VNE properties.

There will be a limitation for the feature in case there are other types of sequances beside username/password in the begining of the sequance
ex:
Password:
>
Password:

A doc bug will be raised to add the limitation in the GUI

Conditions:
1. Have device with the following sequence
Username:
Password:
>
Password:
#
2. Model the device via SSH
3. On PN Administration -> Global Settings -> Security Settings -> User Account Settings
check "Ask for user credentials ..."
4. Run NCCM job/Command builder and add username/password

The job will fail

Workaround:
execute a command when "Ask for user credentials when running device configuration operations" is not checked

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.0(0.1)PP6
Known Fixed Releases: *
4.0(0.2)PP0, 4.2(0.1)PP4
Alert Type:
Updated *
Bug Id:
CSCuv99882
Title:
Cancelled Job:Configrator User is able to see Other User's Cmnd mngr Job
Status:
Open
Severity:
4 Minor
Description: *

Symptom:
After Login to the CCM as configurator ,it is able to see and cancel other user's command manager jobs.

Conditions:
This occurs when Login to the ccm as configurator

Workaround:
No Workaround has been identified.

Further Problem Description:

Last Modified:
11-SEP-2015
Known Affected Releases:
4.2(2.0)PP1
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuv46345
Title:
Catalyst 3550: NumberFormatException in Physical Command Parser
Status:
Fixed
Severity:
4 Minor
Description:

Symptom:
The NumberFormatException originated in CiscoCatalystStackMibUsingDescriptionAndVlanPhysicalCommandParser.

Conditions:
Catalyst 3550, 12.2(44)SE3, VNE.

Workaround:
There is no workaround available.

Further Problem Description:
There are no visible damage to physical inventory; just poor handling of error conditions.

Last Modified:
29-SEP-2015
Known Affected Releases:
4.1(0X)DP1505.0.622
Known Fixed Releases: *
4.0DP1507, 4.1DP1507, 4.2(1)DP1507, 4.2(2)DP1509, 4.2DP1507
Alert Type:
Updated *
Bug Id:
CSCuu13741
Title:
NullPointerException in IsSubTree when parsing traps
Status:
Fixed
Severity:
4 Minor
Description:

Symptom:
NullPointerException in IsSubTree when parsing traps like linkDown, cefcFRURemoved

Conditions:
Not specific

Workaround:
none

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.2(0.1)PP2
Known Fixed Releases: *
4.1(0.1)PP1, 4.2(0.1)PP4, 4.2(1.0)PP1
Alert Type:
Updated *
Bug Id:
CSCuv35430
Title:
CCM: log message appears on the sftp result while distributing.
Status:
Fixed
Severity:
4 Minor
Description: *

Symptom:
Some unnecessary info on the result window when distributing image with sftp.

Conditions:
while distributing image with sftp using CCM.

Workaround:
None

Further Problem Description:

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(1)DP1505.0.622
Known Fixed Releases:
4.2(2)DP1508
Alert Type:
Updated *
Bug Id:
CSCuu93176
Title:
Port utilization alarm for DS1 controller shows wrong location
Status:
Fixed
Severity:
4 Minor
Description:

Symptom:
Port utilization alarm for DS1 controller show wrong location in the long description

Conditions:
Configuration of DS1 controller on SONET interface

Workaround:
none

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
4.0(0.2)PP0
Known Fixed Releases: *
4.1(0.1)PP2, 4.2(0.1)PP3, 4.2(0.1)PP4
Alert Type:
Updated *
Bug Id:
CSCuw29514
Title:
Cat3850xx VNE shows false card in chassis 1
Status:
Open
Severity: *
6 Enhancement
Description:

Symptom:
VNE physical inventory of multi-chassis Catalyst switch contains non-existent card with index 100.

Conditions:
Multi-chassis Catalyst switch Cat385048t

Workaround:
Workaround is not abailable

Further Problem Description:

Last Modified:
28-SEP-2015
Known Affected Releases:
4.1(0X)DP1505.0.622
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuf15027
Title:
ENH: LDAP need to authenticate users belonging to different subgroups
Status:
Fixed
Severity:
6 Enhancement
Description:

Symptom:
PN is not capable of authenticating users, which belong to different groups and subgroups, using LDAP.

Conditions:
Users are scattered over multiple groups and subgroups

Workaround:
None

Further Problem Description:

Last Modified:
07-SEP-2015
Known Affected Releases:
3.9(0.1)PP0
Known Fixed Releases: *
3.10(0.1)PP5, 4.0(0.1)PP6, 4.1(0)PP3, 4.2(0.1)PP4
Alert Type:
New
Bug Id:
CSCuw03751
Title:
No events created when EFP or VLAN tag interface is removed
Status:
Open
Severity:
6 Enhancement
Description:

Symptom:
When the EFP or VLAN configuration is removed from the device the VNE does not create any events. It would be expected to have something like 'EFP interface removed' or 'VLAN interface removed' events with corresponding 'EFP interface added' and 'VLAN interface added' clearing events.

Conditions:
The EFP or VLAN configuration is removed or added to the device.

Workaround:
There is no workaround for this issue.

Further Problem Description:

Last Modified:
01-SEP-2015
Known Affected Releases:
4.2(2.0)PP2
Known Fixed Releases:

Find additional information in Bug Search index.

 

2013 Cisco and/or its affiliates. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks

 

没有评论:

发表评论