Alert Type: | New |
Bug Id: | CSCuv85452 | Title: | VNE is not modeled using SSH |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: |
Symptom: VNE is not modelling with SSH.
Conditions: Model the device SSH v2. Communication state is showing as Device Partially down i.e Telnet/SSH status is down
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(2.601) |
|
Known Fixed Releases: | 4.2(2.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu45704 | Title: | Image Activation Fails with " image not present on Device" |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: |
Symptom: Image Activation Fails with " image not present on Device"
Conditions: While performing 9k Benchmarking for Activation operation, the Activation jobs are failing with " image not present on the Device, even though the image is present on the Device bootflash"
Steps : 1) )Install PN 4.2.1 2)Launch CCM Application with url 'https://172.18.79.14:8043/ccmweb/' 3)Schedule 4 Activation Jobs with 2250 Devices each. 4) Schedule the job with IOS by Image Flow, select image :Image asr1000rp1-adventerprisek9.03.09.01.S.153-2.S1.bin. 5) Verify the results.
Workaround: When the Failed Device is scheduled for activation individually it is passing successfully.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(2), 4.2(2.612) |
|
Known Fixed Releases: * | 4.2(0.1)PP4, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv64507 | Title: | ASR1K LACP LAG appear as Manual |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: ASR1K LACP LAG appear as Manual
Conditions: 1. Model ASR1K 2. Open Inventory -> Logical Inventory -> Ethernet Link Aggregation
Workaround: NA
Further Problem Description:
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: * | 4.1(0X)DP1505.0.622, 4.2(0X)DP1507.0.671 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCum81307 | Title: | Scale CRS VNE is contantly executing/expediting scale registrations |
|
Status: * | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: VNE consumes a lot of memory.
Conditions: Scale CRS device with a lot of VRFs and a large LSE table.
Workaround: no workarounds
Further Problem Description:
|
|
Last Modified: | 29-SEP-2015 |
|
Known Affected Releases: | 3.10(11)XDP1310.0.772, 4.0, 4.1, 4.2, 4.2(1), 4.2(2) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv54343 | Title: | LFA alternative path removed event not correlated to card down and not c |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: LFA alternative path removed event not correlated to card down
Conditions: 1. Model ASR903 2. Card down ASR 903
Workaround:
Further Problem Description:
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: * | 4.1(0.1)PP2, 4.2(0.1)PP4 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv52774 | Title: | The linkDown trap for VLAN trunk port is not associated with interface |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Catalyst 3550 VNE fails associate linkDown trap for Layer2 VLAN trunk port with corresponding interface.
Conditions: Configuration of VLAN interface with no IP address assigned on Catalyst 3550.
Workaround: Not known.
Further Problem Description:
|
|
Last Modified: | 29-SEP-2015 |
|
Known Affected Releases: | 4.1(0X)DP1505.0.622 |
|
Known Fixed Releases: * | 4.1DP1509, 4.2(1)DP1509, 4.2(2)DP1509, 4.2DP1509 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu99423 | Title: | Image distribute some times fails with NullpointerException |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Image distribute fails with NullPointerException
Conditions: NA
Workaround: Try distributing the image again
Further Problem Description:
|
|
Last Modified: | 29-SEP-2015 |
|
Known Affected Releases: | 4.2(1)DP1505.0.611 |
|
Known Fixed Releases: * | 4.1DP1509, 4.2(1)DP1509, 4.2DP1509 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw37340 | Title: | PW not modeled and Bridge has no info |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: no PW and no data under bridge
Conditions: none
Workaround: none
Further Problem Description: none
|
|
Last Modified: | 28-SEP-2015 |
|
Known Affected Releases: | 4.2(1)DP1507.0.663 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuq99569 | Title: | PWHE: No change in subinterface status even when VRF removed in far end. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * |
Symptom: PWHE: No change in the subinterface status even when the VRF is removed in the far end.
Conditions: Noticed when VRF is removed in the far end.
Workaround: Make the VRF interface down, check the syslogs, then the status will get changed.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 28-SEP-2015 |
|
Known Affected Releases: | 4.2(0X)DP0.0.382, 4.2(2) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv82644 | Title: | ASR9912 VNE: Port/card status is not updated in the tree-view |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: Network Vision fails update port and/or card status in the ASR9912 VNE inventory tree-view.
Conditions: ASR9912 VNE
Workaround: Although workaround is exist - reload of the inventory window - it is not acceptable for the end user.
Further Problem Description: Further investigation showed that IManagedElement IMO contains multiple cyclic references, which considered to be the root cause of the external symptoms.
|
|
Last Modified: | 16-SEP-2015 |
|
Known Affected Releases: | 4.1(0X)DP1509.0.682, 4.2(0X)DP1507.0.671 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCui81411 | Title: | Bridge table is not modeling Nexus 1000v. |
|
Status: * | Terminated |
|
Severity: | 3 Moderate |
Description: |
Symptom: Bridge table is not modeled for Nexus 1000v device.
Conditions: Bridge table is not modeled for Nexus 1000v device when more than one VEM is learning the same MAC address.
Workaround: NA
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 09-SEP-2015 |
|
Known Affected Releases: | 4.1(0X)DP0.0.242, 4.2(2) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv57682 | Title: | Path Tracer fails to find trace route for PW originated on ASR9K VNE |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When the Path Tracer is initiated from a pseudo-wire endpoint at the ASR9K VNE, the path shows only local interface. When the same operation is performed from the ME3600 VNE, it works properly showing full trace route.
Conditions: Initiating Path Tracer on pseudo-wire from endpoint on ASR9K VNE.
Workaround: Not known
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(0.1)PP3 |
|
Known Fixed Releases: * | 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCus94180 | Title: | Duplicate representation of EFPs associated to a pseudowire |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Add to Map-> Pseudowire, select a PW associated to an EFP, the same EFP is represented twice - one within the PW container and the other outside.
Conditions: PW discovery and EVC discovery displays PWs attached to EFPs with the EFP represented twice. Add to Map->PW or Add to Map->EVC and select one such PW attached to EFP to view this scenario
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(1)DP0.0.552, 4.2(2)DP1508.0.671 |
|
Known Fixed Releases: | 4.2(2)DP1508 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuv51845 | Title: | Image Distribution: Same device result is showing multiple times. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: Image Distribution: Same device result is showing multiple times on job result page, under successful column.
Conditions: While executing on scale environment it occurs.
Workaround: None.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(2.662) |
|
Known Fixed Releases: | 4.2(2.0)PP1 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuw02666 | Title: | Cancel option is not working for image distribution job that is running. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Cancel the Running Image Distribution Job happens after 5 to 10 minutes
Conditions: After Scheduling the Image Distribution Job and cancel the Job
Workaround: Need to wait for sometime (5 to 10 minutes) to cancel the job
Further Problem Description:
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(2.0)PP1 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv80763 | Title: | QVPC syslogs description not clear and missing information |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: QVPC syslogs description not clear and missing information, include location that is to the ME. Category and Nature are unknown.
The descriptions that are not clear are in card out operations and are: Messaging error General warning New alarm Syslogd err clear alarm
Conditions: 1. Model QVPC device with standby card 2. Card out the standby Port Service Function card (Shutdown VM)
Workaround:
Further Problem Description:
|
|
Last Modified: | 02-SEP-2015 |
|
Known Affected Releases: * | 4.2(2)DP0.0.653 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur83563 | Title: | ISIS information in IOS XR is showing wrong data. |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: IPv4 Metric in ISIS information is showing wrong data.
Conditions: On all IOS XR configured with ISIS.
Workaround: NA
Further Problem Description:
|
|
Last Modified: | 03-SEP-2015 |
|
Known Affected Releases: | 4.1, 4.1(0.999), 4.2, 4.2(0.1)PP4, 4.2(1) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu36668 | Title: | Asr901: Issues in IS-IS technology |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: Issues: 1)Duplicate column 'IS Type' needs to be removed from PN421 2)IS Type column values needs to be populated in PN41 and PN42
Note: Values under this column are populating in PN40 and PN421
Conditions: Steps To Reproduce: 1)Model Asr901 device 2)LI-->IS-IS
Expected Result: 1)Duplicate column needs to be removed 2)Values should be populated under IS Type column
Workaround: Not Applicable
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(0.1)PP4 |
|
Known Fixed Releases: * | 4.2(0.1)PP4, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus77219 | Title: | Link down due to card out between ASR9K IC port to satellite is not clea |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Have setup with 2 ASR9K and ring of 3 satellites Ex:
A9K-CN-ABR1 - SAT 201 (active on ABR1) - SAT 202 (active on ABR1) -SAT 201 (active on ABR3) - A9904-CN-ABR3
And card down MOD80 card (On ABR1), the card that has the IC port. Now card up the card.
"Link down due to card out" ticket between the IC port and the satellite that is connected to the IC port will not be cleaned.
The status of the Satellite port will be unknown and poll not will not solve the issue
Conditions: 1. Model ASR9K with 3 satellites on ring topology 2. Card down MOD80 card (The card that contain the IC port) ex: RP/0/RSP0/CPU0:A9K6-CN-ABR1(admin-config)# hw-module shutdown location 0/1/CPU0 3. Card in the card
Workaround: None
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(0.502), 4.2(1), 4.2(2) |
|
Known Fixed Releases: * | 4.2(0.1)PP4, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus75143 | Title: | ASR9K satellite down event is not correlate to link down |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: "Satellite down" event of satellite that is connected to IC port is not correlated to link down ticket that one of the ports is the IC ports
The satellite is part of satellite ring topology
Conditions: 1. Model 2 ASR9K with satellite ring topology 2. Shutdown IC port of one of the satellite (ex: 10.56.116.223 GE 0/1/1/9)
Workaround: N/A
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(2), 4.2(2.552) |
|
Known Fixed Releases: * | 4.2(0.1)PP4, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv48843 | Title: | SNMP reachability test param change doesnot affect the alarm development |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Change in number of SNMP reachability test retries before the alarm should be created does not affect the Device Unreachable alarm development interval - the alarm continues to be developed within 30-50 seconds.
Conditions: Not specific
Workaround: Not known
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.1(0.1)PP1 |
|
Known Fixed Releases: * | 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu75507 | Title: | ccm config edit comma followed by space introduces new line character |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: New line introduced in any field when there is a comma followed by space in any field during "Configuration Edit" operation in CCM UI.
Conditions: Device configuration has any comments with comma followed by space and if the same config is edited in CCM.
Workaround: do not follow the comma with a space in the comment.
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(0.999) |
|
Known Fixed Releases: * | 4.1(0.1)PP2, 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur68162 | Title: | CCM job/CB exe not work when "Ask for user creds" is en and device is wi |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: PN has the option give the user enter his own creds before execution of NCCM job/Command builder.
In case a device has the following sequance
Username: Password: > en Password: #
and the VNE is modeled via telnet and user will execute a job and add device creds (username and password), PN will use the selected creds and for the rest of the sequance PN will take it from VNE properties(right behavior).
In case VNE is modeled via SSH and user will execute a job and put device creds, PN will fail the job and the following error will appear in the AVM log
java.lang.IllegalArgumentException: cannot create a telnet login command where number of prompts is not the same as number of commands + 1
VNE that is modeled via SSH should act as VNE that is modeled via telnet. Meaning it should use the selected username/password and take the rest of the sequance from the VNE properties.
There will be a limitation for the feature in case there are other types of sequances beside username/password in the begining of the sequance ex: Password: > Password:
A doc bug will be raised to add the limitation in the GUI
Conditions: 1. Have device with the following sequence Username: Password: > Password: # 2. Model the device via SSH 3. On PN Administration -> Global Settings -> Security Settings -> User Account Settings check "Ask for user credentials ..." 4. Run NCCM job/Command builder and add username/password
The job will fail
Workaround: execute a command when "Ask for user credentials when running device configuration operations" is not checked
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.0(0.1)PP6 |
|
Known Fixed Releases: * | 4.0(0.2)PP0, 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv99882 | Title: | Cancelled Job:Configrator User is able to see Other User's Cmnd mngr Job |
|
Status: | Open |
|
Severity: | 4 Minor |
Description: * | Symptom: After Login to the CCM as configurator ,it is able to see and cancel other user's command manager jobs.
Conditions: This occurs when Login to the ccm as configurator
Workaround: No Workaround has been identified.
Further Problem Description:
|
|
Last Modified: | 11-SEP-2015 |
|
Known Affected Releases: | 4.2(2.0)PP1 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv46345 | Title: | Catalyst 3550: NumberFormatException in Physical Command Parser |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: The NumberFormatException originated in CiscoCatalystStackMibUsingDescriptionAndVlanPhysicalCommandParser.
Conditions: Catalyst 3550, 12.2(44)SE3, VNE.
Workaround: There is no workaround available.
Further Problem Description: There are no visible damage to physical inventory; just poor handling of error conditions.
|
|
Last Modified: | 29-SEP-2015 |
|
Known Affected Releases: | 4.1(0X)DP1505.0.622 |
|
Known Fixed Releases: * | 4.0DP1507, 4.1DP1507, 4.2(1)DP1507, 4.2(2)DP1509, 4.2DP1507 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu13741 | Title: | NullPointerException in IsSubTree when parsing traps |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: NullPointerException in IsSubTree when parsing traps like linkDown, cefcFRURemoved
Conditions: Not specific
Workaround: none
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.2(0.1)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP1, 4.2(0.1)PP4, 4.2(1.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuv35430 | Title: | CCM: log message appears on the sftp result while distributing. |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: * | Symptom: Some unnecessary info on the result window when distributing image with sftp.
Conditions: while distributing image with sftp using CCM.
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(1)DP1505.0.622 |
|
Known Fixed Releases: | 4.2(2)DP1508 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu93176 | Title: | Port utilization alarm for DS1 controller shows wrong location |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: Port utilization alarm for DS1 controller show wrong location in the long description
Conditions: Configuration of DS1 controller on SONET interface
Workaround: none
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 4.0(0.2)PP0 |
|
Known Fixed Releases: * | 4.1(0.1)PP2, 4.2(0.1)PP3, 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw29514 | Title: | Cat3850xx VNE shows false card in chassis 1 |
|
Status: | Open |
|
Severity: * | 6 Enhancement |
Description: | Symptom: VNE physical inventory of multi-chassis Catalyst switch contains non-existent card with index 100.
Conditions: Multi-chassis Catalyst switch Cat385048t
Workaround: Workaround is not abailable
Further Problem Description:
|
|
Last Modified: | 28-SEP-2015 |
|
Known Affected Releases: | 4.1(0X)DP1505.0.622 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuf15027 | Title: | ENH: LDAP need to authenticate users belonging to different subgroups |
|
Status: | Fixed |
|
Severity: | 6 Enhancement |
Description: | Symptom: PN is not capable of authenticating users, which belong to different groups and subgroups, using LDAP.
Conditions: Users are scattered over multiple groups and subgroups
Workaround: None
Further Problem Description:
|
|
Last Modified: | 07-SEP-2015 |
|
Known Affected Releases: | 3.9(0.1)PP0 |
|
Known Fixed Releases: * | 3.10(0.1)PP5, 4.0(0.1)PP6, 4.1(0)PP3, 4.2(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuw03751 | Title: | No events created when EFP or VLAN tag interface is removed |
|
Status: | Open |
|
Severity: | 6 Enhancement |
Description: | Symptom: When the EFP or VLAN configuration is removed from the device the VNE does not create any events. It would be expected to have something like 'EFP interface removed' or 'VLAN interface removed' events with corresponding 'EFP interface added' and 'VLAN interface added' clearing events.
Conditions: The EFP or VLAN configuration is removed or added to the device.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 01-SEP-2015 |
|
Known Affected Releases: | 4.2(2.0)PP2 |
|
Known Fixed Releases: | |
|
|
| |