Alert Type: | Updated * |
Bug Id: | CSCul77449 | Title: | PTM ports down after upgrade/revert from 9.533 to 9.522 |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: PTM ports of card 3 in a ENE node went down after reverting from 9.533 to 9.522
Conditions: 1.In 12-Node setup, all nodes were at 9.533 (build-12). All services and traffic are up. 2.Reverted nodes to 9.522 FCS in 2 GNE-10 ENE order 3.After the above, Node N5 PTM card in slot 3 ports went down 4.Card 3 shows up in CTC and IOS but LEDs were off on the card 5. Services on the card are down and hence traffic is affected
Workaround: PTM card should be soft reset
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.533, 9.701 |
|
Known Fixed Releases: * | 15.2(1)SD08 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus16906 | Title: | Card reboot due to exception during deleting a unmanaged vpws ckt |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: Card reboot due to exception during deleting a unmanaged vpws ckt
Conditions: VPWS circuit deletion (rarely)
Workaround: None
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.535 |
|
Known Fixed Releases: * | 15.2(1)SD08 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur54691 | Title: | CPT missing inventory transceivers in CTC |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Optics inventory information missing in inventory details.
Conditions: None. Rarely observed.
Workaround: Active controller softreset.
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.536 |
|
Known Fixed Releases: * | 15.2(1)SD08 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur25480 | Title: | observed unlock semaphore traces in Act PTF console |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: observed unlock semaphore traces in Act PTF console
Conditions: when delete & re-add the protected LSPs when upgrade to Dummy build
Workaround: none
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.701 |
|
Known Fixed Releases: * | 15.2(1)SD08 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur54776 | Title: | CTC really slow on 9.7.0 CPT nodes |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: The card view, alarms, provisioning options took a long time to open particularly with the CPT-50 server polling with a timeout of 10s.
Typically it would take 3-5 minutes to open the CPT-50 node view
Conditions: When SNMP server is added, CTC response becomes very slow with CPT-50 provisioning and opening the node view
Workaround: Remove the SNMP server from the CTC configuration, the CTC response reduces drastically from 3-5 minutes to 3-5 seconds
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.70 |
|
Known Fixed Releases: * | 15.2(1)SD08, 9.7(02) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur43998 | Title: | Due to DMA assertion failure,ipc failed and PB didnt come to card ready |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Due to DMA assertion failure,ipc failed and PB didnt come to card ready
Conditions: 1. All 12 nodes[2 GNE and 10 ENE] were at 9.701[Neptune_Build_24OCT14] in CTC mode and services,traffic were up. 2. Upgraded 2GNE-10ENE nodes to 9.701(Neptune_Build_22OCT14_Dummy) 3. Observed PB didnt come to card ready state in one of the ENE Node.Due to DMA assertion failure, ipc failed.
Workaround: Reset PB
Further Problem Description:
|
|
Last Modified: | 14-SEP-2015 |
|
Known Affected Releases: | 9.701 |
|
Known Fixed Releases: * | 15.2(1)SD08 |
|
|
| |