Alert Type: | Updated * |
Bug Id: | CSCuq60604 | Title: | CRS connected with LMP dynamic link are not rediscovered |
|
Status: * | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: The CRS connected to ONS 15454 with dynamic LMP links are not automatically discovered after deletion
Conditions: In a network where CRS (4.2.3) is connected to ONS 15454 with dynamic LMP links , if user deletes the CRS from the topology, the CRS is no more rediscovered
Workaround: None
Further Problem Description:
|
|
Last Modified: | 05-AUG-2015 |
|
Known Affected Releases: | 10.0(2.0.134), 10.3(0.0.1) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuv62714 | Title: | Exception when deleting an M6 shelf |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Description : Scenario: Single Server, small size, release 10.005(000.000.100) Patch applied: .
In a multishelf node, when deleting from CTC a subtending M6 chassis, CPO raises an exception in the Java Console. The exception is occurring roughly 7 times out of 10.
On NE Explorer the M6 chassis is always removed, even with the presence of the exception.
Please, check the attached exception log for reference.
Expected behavior : No excpetions should be raised when deleting a subtending chassis.
Conditions: Steps to Reproduce : 1. Open a multishelf NE 2. Provision and empty M6 subtending chassis from CTC. 3. verify that the new chassis is added to the NE Explorer view. 4. Delete the new M6 chassis from CTC. 5. Verify the CPO Java Console log for the exception
Workaround:
Further Problem Description:
|
|
Last Modified: | 05-AUG-2015 |
|
Known Affected Releases: | 10.5(0.0.103) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuv63110 | Title: | CRS Facility Report does not update the Admin State field |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: Description : Scenario: Single Server, small size, release 10.005(000.000.108) Patch applied: .
On the CRS, the Admin State field in the The Facility Report is not updated.
When changing the Admin State of one PLIM card from CTC, the modification is never reflected in the Facility Report. The Facility Report seems to be unaware of the modification (no yellow band for changes) and even forcing a refresh with the icon does not update the field.
Please, check the attached screenshot for reference.
Expected behavior : The Facility Report should always report the correct Admin State
Conditions: Steps to Reproduce : 1. Modify the Admin State of the PLIM port from CTC 2. Verify that the Facility Report does not receive the modification (no yellow band) 3. Verify that selecting the Refresh icon the Admin State remains unchanged
Workaround:
Further Problem Description:
|
|
Last Modified: | 05-AUG-2015 |
|
Known Affected Releases: | 10.5(0.0.108) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuv73696 | Title: | Slot numbers not coming in the shelf on GIF |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Not able to see the slot number on shelf on GIF.
Conditions: N/A
Workaround: N/A
Further Problem Description: N/A
|
|
Last Modified: | 29-AUG-2015 |
|
Known Affected Releases: | 10.5(0.0.116) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuo27343 | Title: | Can't create P2P L2 topologies from CPO |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When creating a L2 Topology on CPO 9.8 point-to-point, the system does progress forward after selecting the source and destination device
Conditions: Attempting to create a Point-to-Point L2 topology between 2 ML cards.
Workaround: None
Further Problem Description:
|
|
Last Modified: | 07-AUG-2015 |
|
Known Affected Releases: * | 10.0(0.1), 9.8(0.2) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus40011 | Title: | Proactive Protection Regan tab displays incorrect values for 200G-CK-LC |
|
Status: * | Terminated |
|
Severity: | 3 Moderate |
Description: | The Proactive Protection Regan tab for the 200G-CK-LC card displays incorrect values for Prime Optical and Cisco Transport Controller
Symptom: The Proactive Protection Regan tab for the 200G-CK-LC card displays incorrect values for Prime Optical and Cisco Transport Controller. N/A value is displayed in Cisco Transport Controller. However, Prime Optical displays values for the Trigger Threshold details.
Conditions: As above
Workaround: NA
Further Problem Description:
|
|
Last Modified: | 26-AUG-2015 |
|
Known Affected Releases: | 10.5(0) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuw01090 | Title: | Cannot create STM manual physical links on 15305 2.0 NEs |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: It is not possible to create any STM manual link (layer=physical, provition type=manual) betwen a ONS15454 and a 15305 2.0 NE.
Conditions: User attempts to create a manual physical STM1 or STM4 link betwen a 15454 SDH and 15305 2.0 device.
Workaround: None
Further Problem Description:
|
|
Last Modified: | 29-AUG-2015 |
|
Known Affected Releases: | 10.3(0.3) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCtq39756 | Title: | CTM - Jboss application server - vulnerable jmx-console |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptoms: The Jboss application server comes with a vulnerable bean shell component of the jmx-console which perform access control only for GET and POST methods.
Conditions: none Workaround: Follow these steps:
1) Shut down the CTM server using ctms-stop.
2) Locate the following files, create a backup copy for each of them, and open them with an editor: /opt/CiscoTransportManagerServer/jms/server/all/deploy/jbossweb-tomcat50.sar/server.xml /opt/CiscoTransportManagerServer/jms/server/default/deploy/jbossweb-tomcat50.sar/server.xml
3) In each file, comment the sections that begin with the lines: HTTP/1.1 Connector on port 8080 and AJP 1.3 Connector on port 8009
4) Startup the CTM server using ctms-start.
Further Problem Description: The vulnerability is further described in CVE-2010-0738 PSIRT Evaluation: The Cisco PSIRT has assigned this bug the following CVSS version 2 score. The Base and Temporal CVSS scores as of the time of evaluation are 5/4.5: http://tools.cisco.com/security/center/cvssCalculator.x?vector=AV:N/AC:L/Au:N/C:P/I:N/A:N/E:F/RL:W/RC:C&version=2.0 CVE ID CVE-2010-0738 has been assigned to document this issue. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html |
|
Last Modified: | 06-AUG-2015 |
|
Known Affected Releases: | 7.0, 7.2, 8.0, 8.5, 9.0, 9.1(0.1) |
|
Known Fixed Releases: | 9.1 |
|
|
| |