Bug Id: | CSCue34250 |
Title: | WCCP traffic can't redirect after reloading the switch |
|
Description: | Symptom: WCCP traffic can't redirect after reloading the switch
Conditions: since using 15.0.2SE or later Workaround: remove the wccp redirects command from the interface and put it back on it.
verify label information. switch#show platform ip wccp label ID Label 0 22 1 23 |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Last Modified: | 15-JUL-2015 |
|
Known Affected Releases: | 15.2(1.1) |
|
Known Fixed Releases: | 15.0(2)EJ, 15.0(2)EJ1, 15.0(2)SE3, 15.0(2)SE4, 15.0(2)SE5, 15.0(2)SE6, 15.2(1)E, 15.2(1)E1, 15.2(1)E2, 15.2(1)E3 |
|
|
| |
| |
Bug Id: | CSCuj75125 |
Title: | SFP GLC-SX/GLC-T do not pass traffic when inserted in C3KX-SM-10G |
|
Description: | Symptom: SFP modules GLC-SX/GLC-T/GLC-LH-SMD when inserted in to C3KX-SM-10G on 3560-X switch running 15.2(1)E, are not passing traffic.
Conditions: IOS should be 15.2(1)E. Older IOS versions are not affected. The issue is seen on 3560X and 3750X boards with HW revision no less than 3.
Workaround: Downgrade to IOS 15.0(2)SE Train, till the fix is pending.
Further Problem Description:
|
|
Status: | Fixed |
|
Severity: | 2 Severe |
Last Modified: | 16-JUL-2015 |
|
Known Affected Releases: | 15.2(1.1) |
|
Known Fixed Releases: | 15.2(1.1)PSR, 15.2(4.0)ST |
|
|
| |
| |
Bug Id: | CSCum56403 |
Title: | FSPAN session can't work again after Reloading vlan-based FSPAN session |
|
Description: | Symptom: configured many lines of ACL which applied for FSPAN, and see below log messages which shows The ACL manager cannot store the FSPAN configuration,and this feature has been temporarily disabled for the session. and we saw that can't capture packets by monitor session.
--------------------------------------- %ACLMGR-4-UNLOADINGFSPAN: Unloading vlan-based FSPAN session 1 Macand IP feature ---------------------------------------
then we do configuration change to delete ACLs and make the ACL manager to reload the FSPAN session, but FSPAN session can't start to work again and no packets can be captured.
----------------------------------------------------------- %ACLMGR-4-RELOADEDFSPAN: Reloading vlan-based FSPAN session 1 IP feature -----------------------------------------------------------
after delete and re-configure the FSPAN session config, it will starts to work again and packets can be captured normally.
=============================== vlan access-map xxx 999 match ip address xxx action drop log
vlan filter xxx vlan-list 999
monitor session 1 source vlan 999 rx monitor session 1 destination interface Gi0/1 monitor session 1 filter ip access-group xxx ===============================
Conditions:
Workaround: delete and re-configure the FSPAN session config, it will starts to work again and packets can be captured normally.
Further Problem Description:
|
|
Status: | Fixed |
|
Severity: | 2 Severe |
Last Modified: | 16-JUL-2015 |
|
Known Affected Releases: | 15.0(2)SE5 |
|
Known Fixed Releases: | 15.0(2)SE6, 15.2(2)E, 15.2(2b)E, 15.2(4.0)ST |
|
|
| |
| |
Bug Id: | CSCuo50456 |
Title: | WS-C3560X high CPU with REP LSL Hello PP Process during failover |
|
Description: | Symptom:High CPU problem found on WS-C3560X with REP running.
Conditions:The STCN sent by first segment is looping back since the 2nd and 3rd segments also configured to transmit the STCN occurred in their segment back to first segement.
Workaround:None.
More Info:
|
|
Status: | Fixed |
|
Severity: | 2 Severe |
Last Modified: | 16-JUL-2015 |
|
Known Affected Releases: | 15.0(31.4.119) |
|
Known Fixed Releases: | 15.0(2)SE7, 15.2(2)E1, 15.2(2.54)PSR, 15.2(2b)E, 15.2(3)E, 15.2(4.0)ST, 3.6(1)E, 3.7(0)E |
|
|
| |
| |
Bug Id: | CSCuv17071 |
Title: | 3560x: PoE Available Power drops to 370w from 1440w on 152-3.E1 |
|
Description: | Symptom: 3560-X Switches will report available PoE power of 370w after upgrading IOS to 152-3.E1. PoE devices connected to the switch will be affected, as the switch will believe it does not have enough power for the devices.
Conditions: A 3560-X switch with an 1100WAC power supply or similar, configured for PoE.
After upgrading to 152-3.E1, "show power inline" will list total available power as 370W instead of the correct value.
This will impact PoE hosts, as PoE will be denied once it exceeds the 370w value.
Workaround: Downgrade to 152-3.E. Upgrade to fixed version of IOS. This issue is specific to 152-3.E1.
Further Problem Description:
|
|
Status: | Fixed |
|
Severity: | 2 Severe |
Last Modified: | 20-JUL-2015 |
|
Known Affected Releases: | 15.2(3.7.1) |
|
Known Fixed Releases: | 15.2(4.0.40)E |
|
|
| |