Alert Type: | Updated * |
Bug Id: | CSCux44480 | Title: | NIOTelnetAdapter returns 'empty' response with prompt for 'show' CLI |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: Sometimes the NIOTelnetAdapter returns 'empty' response with correct prompt for 'show' CLI command when it is expected to have echo of the CLI command (missing part) then the telnet result following by telnet prompt.
Conditions: Not known specific conditions
Workaround: There is no workaround for this issue
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP2, 4.2(1) |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux29339 | Title: | VNE fails to get single context inventory from multi-context device |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: Missing most of context logical inventory, which is obtained from Telnet protocol.
Conditions: Multi-context device has configuration of single context - no switching between context is available.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP5, 4.2(2.0)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6, 4.2(2.0)PP3 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux54694 | Title: | Fatal NullPointerException in AVM100 shuts down event processors |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: Due to Fatal NullPointerException in AVM100 the event processors for VNEs are getting shut down and the notifications are getting dropped.
Conditions: Temporary loss of communication between VNE and AVM100, which causes renewal of event processors for VNE.
Workaround: Restart AVM100
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6, 4.2(2.0)PP4 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz26537 | Title: | P-PN: importing Ldap user to PN with mandatory attribute fail |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: importing LDAP user must fill in the optional parameters.without the optional parameters the import fail need to change the instruction under the guide
Conditions: Importing Ldap user to prime network using import_users_from_LDIF_file.pl script without optional parameters.
Workaround: Run the script and fill in as parameters also optionals
Further Problem Description:
|
|
Last Modified: | 04-MAY-2016 |
|
Known Affected Releases: | 4.2(2.0)PP6 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCut06773 | Title: | Subinterface&Pw of a regular bridge are incorrectly contained in EVC |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: The components (Sub interface or EFP) connected to a regular bridge with an association such as pseudowire or vfi are shown in EVC discovery as separate entities and does not represent the actual connection of the components ie EFP/Subinterface ->Regular bridge ->Association (vfi/pseudowire) This is because Regular bridges with associations are not displayed in bridge domain discovery (Feature implementation ).Hence, the components such as EFP /L3-Sub-interface will be contained in the EVC discovery along with the association such as vfi or pseudo wire without the regular bridge connecting them and hence is misleading as it will display only the name of the regular bridge which actually joins both the component and the association
Conditions: From Add to Map->EVC discovery an EVC of the association ie vfi or pseudowire of the regular bridge and the components such as EFP or L3-subinterface is formed without actually representing the exact network scenario as regular bridges will not be discovered as part of Bridge domain discovery
Workaround: None
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 12-MAY-2016 |
|
Known Affected Releases: * | 4.2(1), 4.2(1)DP0.0.552, 4.2(1)DP0.0.561, 4.2(3) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus36751 | Title: | NEXUS7K card content disappear after card down |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: NEXUS7K content disappear after card down
Conditions: 1. Model Nexus7K 2. Card down Nexus7K ((config)# poweroff module 1)
Workaround:
Further Problem Description:
|
|
Last Modified: | 12-MAY-2016 |
|
Known Affected Releases: * | 3.10(11)XDP1403.0.821, 4.1(0X)DP1411.0.502, 4.2(0X)DP1503.0.581, 4.2(0X)DP1509.0.702, 4.2(1)DP1505.0.622, 4.2(2)DP1603.0.822, 4.2(3)DP0.0.831 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz60245 | Title: | P-PN:Physical inventory doens't model for CPT 200 in PN 4.1 |
|
Status: * | Other |
|
Severity: * | 3 Moderate |
Description: | Symptom: CPT200 Physical inventory doesn't model
Conditions: Model CPT 200 in PN 4.1.0.1.4 with DP1603 or previous DP version
Workaround:
Further Problem Description:
|
|
Last Modified: | 19-MAY-2016 |
|
Known Affected Releases: | 4.1(0X)DP1603.0.822 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux71052 | Title: | Failure in taking recording of Juniper when community has '/' char |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Failure in taking recording of Juniper when community has '/' char
Conditions: Juniper devices with '/' in community
Workaround: Change community and remove '/
Further Problem Description: Need to check if it works fine with Cisco devices
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP5, 4.2(2.0)PP3 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP4 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz52738 | Title: | ASR1K , does not have QOS container |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: ASR 1k does not have QOS container
Conditions: 1) Model ASR 1k 10.56.25.155 . 2) Create QOS policy in any interface . 3) Check the QOS container in the Logical inventory .
Workaround:
Further Problem Description:
|
|
Last Modified: | 04-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP4 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz64899 | Title: | PN - CDP Neighbor entries are not appearing in Nexus 5k inventory |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: Missing entries in CDP Table of Logical Inventory for Nexus 5k
Conditions: None
Workaround: None
Further Problem Description:
|
|
Last Modified: | 30-MAY-2016 |
|
Known Affected Releases: | 4.1(1.1)PP4 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz37956 | Title: | Limitations due to HW snmp defects on ASR5K |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: * | Symptom: Limitations due to HW snmp defects on ASR5K
Conditions: ASR5K management ports and Console port
Workaround: None
Further Problem Description: None
|
|
Last Modified: | 02-MAY-2016 |
|
Known Affected Releases: | 4.2(2) |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu36668 | Title: | Asr901: Issues in IS-IS technology |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: |
Symptom: Issues: 1)Duplicate column 'IS Type' needs to be removed from PN421 2)IS Type column values needs to be populated in PN41 and PN42
Note: Values under this column are populating in PN40 and PN421
Conditions: Steps To Reproduce: 1)Model Asr901 device 2)LI-->IS-IS
Expected Result: 1)Duplicate column needs to be removed 2)Values should be populated under IS Type column
Workaround: Not Applicable
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 03-MAY-2016 |
|
Known Affected Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP4 |
|
Known Fixed Releases: | 4.2(0.1)PP4, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCup00169 | Title: | Removing an RSP cards - chassis disconnect alarm is generated |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: After removing an RSP card, chassis disconnect alarm is generated (device have only one chassis), and getting cleared after ~30 seconds.
Conditions: When the RSP is removed the device doing a warm startup which restart the entity mib process on the device. It takes 20-40 seconds for the entity mib to get populated again. When the VNE gets the OIROUT syslog it immediately expedite the physical command (no delay) and gets an empty result for all the entity mib and thus chassis disconnect alarm is generated.
Workaround: N/A
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.0(0X)DP1403.0.873 |
|
Known Fixed Releases: * | 4.0DP1407, 4.1DP1409, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz30577 | Title: | False Alarms Memory utilization when QvPC-SI has more than one node |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Results in false memory utilization alarms
Conditions: When QvPC-SI has more than one node
Workaround: none
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1603.0.822 |
|
Known Fixed Releases: * | 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz14457 | Title: | ASR1K to use new 64bit MIB parameters for Memory utilization alarm |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: False memory utilization alarm generated in Prime Network for ASR 1k device
Conditions: ASR 1k devices
Workaround: NONE
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1603.0.802, 4.2(2) |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz74396 | Title: | LDP neighbor down syslog new format has to be parsed |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: LDP neighbor down syslog is not parsed.
Conditions: When VNE receives the following syslog. Syslog message: LOCAL7.NOTICE: 85854: RP/0/RP0/CPU0:Feb 1 08:20:57.087 EST: mpls_ldp[1042]: %ROUTING-LDP-5-NBR_CHANGE : VRF 'default' (0x60000000), neighbor 11.31.112.18:0, DOWN (Session KeepAlive Timer expired) \n
Workaround: None
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(2) |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz38011 | Title: | Prime Network is running commands multiple times |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Prime Network is running commands multiple times
Conditions: Restart a VNE
Workaround:
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(2)DP1603.0.822 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy95215 | Title: | The NSVC down/up trap alarms need to have unique identifier |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Some of the 'NSVC down' trap tickets stay not cleared for prolonged period of time when other cleared tickets continue accumulate lots of clearing 'NSVC up' trap alarms.
Conditions: Configuration of SVC on the devices and development of NSVC traps when SVC carrying interface is getting down/up.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1601.0.791 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy74775 | Title: | CCM: Nexus 7k Config backup fails using SFTP except for default VDC |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Config backup fails for all VDC (except default VDC).
Conditions: device : Nexus 7k. Transfer protocol: SFTP.
Workaround: Use other transfer protocols if management VRF is used.
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(2)DP1601.0.791 |
|
Known Fixed Releases: * | 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz12883 | Title: | PN: SCE 2000 physical inventory not discovered |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: SCE 2000 physical inventory is missing.
Conditions: Normal discovery
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(2) |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz55557 | Title: | asr5k tickets that are not cleared |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: ASR5K tickets are having INFO severity instead CLEAR
Conditions: none
Workaround: none
Further Problem Description: none
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1601.0.791, 4.2(0X)DP1603.0.822, 4.2(2)DP1605.0.862 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux86095 | Title: | Missing some physical links configured on SONET E1 channels |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: The map in NV does not show all physical links configured on SONET channelized E1 serial interfaces reported in CDP table. The CDP Neighbor Table in VNE Logical Inventory does not show any hyperlinks for serial interfaces.
Conditions: Configuration of E1/T1 SONET channels that are used to connect to other devices. CDP is enabled.
Workaround: none
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1, 4.1(0.1)PP3, 4.2, 4.2(0.1)PP6, 4.2(2), 4.2(3) |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCut04573 | Title: | IllegalDestinationAddressException in BfdCorrelationResolvingFlowMH |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Sometimes VNE fails develop 'BFD connectivity down/up' or 'BFD neighbor lost/found' alarms. due to IllegalDestinationAddressException in BfdCorrelationResolvingFlowMH.
Conditions: The symptoms can appear in some use cases, like card out, which causes IPInterface DC associated with BFDSession DC to be removed.
Workaround: none
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.0(0.1)PP6, 4.1, 4.1(0)PP4, 4.2, 4.2(1), 4.2(2) |
|
Known Fixed Releases: * | 4.1(0.1)PP0, 4.1(0.1)PP4, 4.2(0.1)PP1, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCun90467 | Title: | No physical links discovered between T1 interfaces with PPP/MLPPP config |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: None of the Layer 1 or Layer 2 topology links between T1 interfaces with PPP and MLPPP configuration have been discovered.
Conditions: PPP or MLPPP configuration on T1 interfaces.
Workaround: None.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 3.11(0)PP2 |
|
Known Fixed Releases: * | 3.11(0)PP4, 4.1(0.1)PP4, 4.2(2.0)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw28551 | Title: | Java Exception for EGTP Service in logs for asr5k |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: |
Symptom: 1. Model ASR5500 Device 2. Create a context and configure EGTP Service for that context 3. Check AVM Logs
Conditions: Getting the below exception :
CiscoASR5kEGTPTelnetParser.getInterfaceType - Error while extracting InterfaceType info in line java.lang.IllegalArgumentException: Unknown enumeration name [cgw-egress] in com.sheer.types.enums.EgtpServiceInterfacesTypeEnum
Workaround: ASR5500 Device
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP2, 4.2(1.0)PP1, 4.2(2.0)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu84813 | Title: | lotem ssh ghost connection prevents new connections |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: VNE looses ssh connection after device reload and does not recover SSH Connection once device is available
Conditions: Conditions: * device ASR 920 * VNE up and running connected via ssh * device is reloaded
Workaround: restart VNE
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0)PP4, 4.2(0.522), 4.2(1.0)P1, 4.2(1.0)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP3, 4.2(0.1)PP4, 4.2(0.1)PP6, 4.2(2) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux09483 | Title: | NCCM: Image Files are not fetched from external Server to distribute |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: External repository from the Change and Configuration management(CCM) (Images->Repository->Import External Repository) showing as No data available
Conditions: When external server is used with different date format.
Workaround: Check whether "ls -l" on the external server returning as below format.
pn@tier4-rhel-vm10 [~/XMP_Platform]% ls -l drwxr-x--- 9 user group size MMM DD HH:MM
Example: % ls -l drwxr-x--- 9 test grp 10 Oct 21 10:16 test.txt
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(2), 4.2(3) |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6, 4.2(2.0)PP4, 4.2(3) |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz51469 | Title: | Compliance Audit job , page was not loading properly |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Config Audit job page is not loading with results
Conditions: 1) Open the NCCM , Create a compliance policy 2) create a Policy profile and add the Compliance policy created .
3) Run the policy profile .
4) Compliance Audit job will be created . Navigate to Compliance Audit --> Jobs
5) Jobs has to be shown . In 4.1.0.1.4 jobs was no shown and the page was not loading properly .
tried in all the browsers , Firefox , Chrome , IE 8 and IE 11 .
Workaround:
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP4 |
|
Known Fixed Releases: * | 4.1(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy72149 | Title: | CRSX-533 VNE: Wrong line card location in cefc FRU trap alarms |
|
Status: | Other |
|
Severity: | 3 Moderate |
Description: | Symptom: When performing an OIR on card 20X10 GBE in CRS X running XR 533, a cefc FRU Removed/Inserted trap alarms were raised for a different slot number.
Conditions: OIR on line card in CRSX, version 533.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP6 |
|
Known Fixed Releases: * | 4.1(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux38480 | Title: | NCCM Config Restore Failure |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: NCCM Config Restore get failed.
Conditions: Restoring archive get failed for device type:ASR 903 15.3(3)S3. Errors show it having issues with handling the MOTD banner characters.
Workaround: Restoring archive got succeed after editing archive file manually(Removed problematic MOTD banner).Find MOTD banner in attachment.
Further Problem Description: None
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP0, 4.1(0.1)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6, 4.2(2.0)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy53128 | Title: | physical links between POS interfaces not shown for ASR9k |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Physical link maps do not show the links
Conditions: Physical links between POS Interfaces for ASR9K devices
Workaround: none
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(2.0)PP3 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP5 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux53448 | Title: | InfoBright is flooding avm25 log and causing it to crash |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: floods of java.sql.SQLException: Could not commit with auto-commit set on in avm 25 log and even crash of avm 25
Conditions: InfoBright installed. High event rate.
Workaround: stop InfoBright.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(1.0)PP1, 4.2(2.0)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP4, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu93256 | Title: | PN - NCCM - Command Manager Preview fails |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Unable to preview Command Manager script output prior to execution Getting the following error: Can't find resource for bundle java.util.PropertyResourceBundle, key Unable to fetch DP name
Conditions: All Devices All Commands (new + predefined)
Workaround: None
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP3, 4.2(0.1)PP5, 4.2(1.0)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy46140 | Title: | Nexus VNE does not create 'Port up' on VNE init, fails clear open alarms |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: When Nexus VNE is started it does not develop 'Port up' alarms and fails to clear open alarms. The 'Poll now' also fails to clear open alarms although port status is updated from Down to Up.
Conditions: Modeling of Nexus devices
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP6 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP6, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu80402 | Title: | ERRORs get GoldenSource IP and BeanShell script error appear in ASR9K lo |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: ERRORs getting GoldenSource IP and BeanShell script error appear in ASR9K log
Conditions: 1. Model ASR9K 2. Look in AVM log
Workaround:
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(1.0)PP1, 4.2(2.631) |
|
Known Fixed Releases: * | 4.1(0.1)PP4 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCus75245 | Title: | ASR9K satellite Host roll is not updated after IC port down |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * | Symptom: ASR9K "Satellite Host roll" is not updated after IC port down. The Active satellite stay active even that the satellite is not plug any more to the ASR9K
Conditions: 1. Model 2 ASR9K with 3 satellites on ring topology 2. Shutdown IC port of one of the satellite
Workaround: Not Applicable
Further Problem Description:
|
|
Last Modified: | 24-MAY-2016 |
|
Known Affected Releases: | 4.2(0.522), 4.2(1) |
|
Known Fixed Releases: | 4.2(2), 4.2(2.0)PP2 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux92634 | Title: | Tech Changes for 'DNS PGW Context' attribute in MRME service. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: * |
Symptom: Tech Changes for 'DNS PGW Context' attribute in MRME service. (MRME attribute - 'DNS PGW Context' should come as a Hyperlink in PN)
Conditions: Confiugure DnsPgwContext attribute in MRME service as XID.
Workaround: There is no workaround for this issue.
Further Problem Description:
(release notes added by addprefcs-org.ksh)
|
|
Last Modified: | 24-MAY-2016 |
|
Known Affected Releases: | 4.2(3), 4.2(3.791) |
|
Known Fixed Releases: | 4.2(2.0)PP6, 4.2(3) |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz80776 | Title: | CRS-3: VNE associated cefcFRURemoved/Inserted traps with wrong module |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: While running card OIR test on CRS-3 router it was noticed that developed trap alarms for cefcFRURemoved/Inserted traps are associated with wrong card location.
Conditions: CRS-3. Card OIR test
Workaround: none
Further Problem Description:
|
|
Last Modified: | 25-MAY-2016 |
|
Known Affected Releases: | 4.2(2)DP1603.0.822 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz82703 | Title: | MplsTeTunnel DC loses connection to Mpls DC when tunnel is rerouted |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: When a TE-tunnel on device is rerouted, in the VNE DC model corresponding MplsTeTunnel DC loses connection to the old Mpls DC, but does not establish connectivity to the new one.
Conditions: MPLS TE-tunnel gets rerouted for any reason.
Workaround: Restart VNE
Further Problem Description:
|
|
Last Modified: | 26-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP3 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw33949 | Title: | ISIS neighbor IRD for ipv4 and ipv6 is created with the same DC key -9K |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: isis neighbors does not show ipv4 and ipv6 if both enabled
Conditions: ipv4 and ipv6 isis neighbors configured
Workaround: none
Further Problem Description: none
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(1)DP1507.0.663 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(3)DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz55029 | Title: | LDAP SSL missing system restart |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: * | Symptom: LDAP SSL installation will not work as documented in: http://www.cisco.com/c/en/us/td/docs/net_mgmt/prime/network/4-0/administrator/guide/CiscoPrimeNetwork40AdministratorGuide/users.html#57921
Conditions: I chose the 4.0 guide link, but it is wrong in all versions of the document.
Workaround: The section "Installing the LDAP Certificate on the Prime Network Gateway Server" needs an additional step. After " Step 5 Enter the following command to check your LDAP certificates on the system.truststore file: # keytool -list -keystore.truststore "
We need to add the following:
"Step 6 Restart the prime network gateway. # anactl restart"
Further Problem Description:
|
|
Last Modified: | 09-MAY-2016 |
|
Known Affected Releases: | 4.0(0)PP999, 4.1(0)PP999, 4.2(0)PP999, 4.2(2)DP0.0.653 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz05430 | Title: | N7K VNE: The 'VPC Peer unreachable' syslog alarm must be informational |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: In VPC link down test it was noticed that 'VPC Peer unreachable' ticket stays not cleared indefinitely.
Conditions: Configuration of VPC domain
Workaround: Using VCB change the syslog event alarm to informational.
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1601.0.791 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy70534 | Title: | IGMP and PIM table missing Associted Entries for VRF interfaces |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: When PIM and IGMP entries configured on VRF interfaces the NV does not show corresponding Associated Entries in Network Vision.
Conditions: PIM and/or IGMP entries configured on VRF interfaces
Workaround: There is no workaround for this issue
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.2(0X)DP1605.0.842 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw57111 | Title: | NCCM dont show config archive when device banner login contain $ |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: NCCM dont show config archive when device banner login contain $
Conditions:
Workaround: remove the $ from device banner
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP2, 4.2(2.0)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuz69666 | Title: | Could not add/remove description in Sonet interface of 7600 |
|
Status: | Open |
|
Severity: | 4 Minor |
Description: | Symptom: When trying to add/remove/edit description in Sonet interface in Cisco 7600 , the command gets failed .
Conditions: 1) Login to Vision , Right click on the E1 interface ->Commands--> Configuration -->Add port description 2) try the same with Edit and Update port description .
Workaround:
Further Problem Description:
|
|
Last Modified: | 19-MAY-2016 |
|
Known Affected Releases: * | 4.1(0X)DP1605.0.851 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux50778 | Title: | NullPointerException in LSE.getConnectionIPsForMplsTETunnel |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: The flood of NullPointerException in LSE.getConnectionIPsForMplsTETunnel errors when tunnel interface was removed from configuration.
Conditions: MPLS L3VPN configuration.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(0.1)PP6, 4.2(2.0)PP4, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux02468 | Title: | NullPointerException in CommandHandler while processing NULL SNMP values |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: VNE is logging flood of NullPointerException errors, which caused by NULL SNMP values.
Conditions: Requested SNMP objects not populated in the device MIB and device returns NULL values.
Workaround: There is no workaround for this issue.
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.1(0.1)PP2 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(2.0)PP3 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux85713 | Title: | PN - UNEXPECTED ERROR DURING AGENT EXECUTION - VNEPersistedQueue |
|
Status: | Fixed |
|
Severity: | 4 Minor |
Description: | Symptom: Fatal Null Pointer Exception messages presented in AVM100 log file..
FATAL - OSAgent.handleThrowable - UNEXPECTED ERROR DURING AGENT EXECUTION! java.lang.NullPointerException at com.sheer.metrocentral.framework.instrumentation.trap.util.VNEPersistedQueue.invalidateEvents(VNEPersistedQueue.java:38) etc...
Conditions: Unknown
Workaround: None
Further Problem Description:
|
|
Last Modified: | 23-MAY-2016 |
|
Known Affected Releases: | 4.2(0.1)PP6, 4.2(2), 4.2(3), 4.2(3.0)PP1 |
|
Known Fixed Releases: * | 4.1(0.1)PP4, 4.2(3.0)PP1 |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw63055 | Title: | Syslog 'CLNS-5-ADJCHANGE' parsing rules do not expedite ISIS inv update |
|
Status: | Fixed |
|
Severity: | 6 Enhancement |
Description: | Symptom: ISIS state changes on the device do not appear in VNE. This happens due to ISIS syslog parsing rules for IOS and IOS XR devices do not expedite any registrations.
Conditions: Configuration of ISIS in Cisco devices.
Workaround: As a workaround it is suggested to use Regular Poling for the Cisco 6524 VNEs, which will update ISIS inventory every 'configuration' interval (default is 15 minutes).
Further Problem Description:
|
|
Last Modified: | 27-MAY-2016 |
|
Known Affected Releases: | 4.1(0X)DP1507.0.702 |
|
Known Fixed Releases: * | 4.1DP1605, 4.2(2)DP1605, 4.2(3)DP1605, 4.2DP1605 |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCun76425 | Title: | VCB GUI: Test Event Feature Enhancements |
|
Status: | Open |
|
Severity: | 6 Enhancement |
Description: | Symptom: Prime Network VCB does not auto-fill the varbind values when a supported trap is selected for 'Test Event'
Conditions: Under all conditions
Workaround: None. The user has to manually enter all varbind OIDs and values.
Further Problem Description:
|
|
Last Modified: | 05-MAY-2016 |
|
Known Affected Releases: | 4.2(0.999) |
|
Known Fixed Releases: | |
|
|
| |
没有评论: