Symptom: configuring SNMP on an ME-1200 through an NID controller which is an me3600x:
steps to configure it:
controller nid 1/1 ProvisionSnmpConf setSnmpServerConf snmp_server_conf snmp_server enable setSnmpServerConf snmp_server_conf version v2c setSnmpServerConf snmp_server_conf trap enable setSnmpServerConf snmp_server_conf community_v2c comm_name setSnmpServerConf snmp_server_conf community_v2c mode ro setsnmpserverConf commit
checking the SNMP info:
GetSnmpServerConf_Output.snmp_server_conf.community_v2c.comm_name = ' <-- Truncated
Conditions: Reading SNMP community string back from ME1200 that was pushed from Me3600 you can see that the community string is truncated and not the full text.
This is cosmetic and does not affect the functionality of SNMP
Workaround: none
Further Problem Description:
|