Cisco Blog » The Platform

2016年5月1日星期日

Cisco Notification Alert -3750X Series Switch-01-May-2016 16:53 GMT

 

 

 

 

 

 

 


Known Bugs - Catalyst 3750-X Series Switches

Alert Type:
Updated *
Bug Id:
CSCuh97014
Title:
C3KX-SM-10G: remote port CTS link down after 3750X master reload
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
If we reload 3750X/3560X stack Master , CTS link configured on CK3X-SM-10G port on member switch goes down (which was UP before the master reload)

Conditions:
3750X/3560X stack of atleast 3 switches , wherein
a Master Switch, alternate-Master ( i.e switch with next highets priority) and a member switch with CK3X-SM-10G module.
On the Member Switch , CTS is configured on CK3X-SM-10G port(s)

If we reload Master, alternate Master will be become new Master. After this, CTS link configured on one of the ports of CK3X-SM-10G installed on Member Switch goes down.


Workaround:

The CTS link can be restored (i.e brought UP) by doing a shut/no shut on the ports on the
SM module

Last Modified:
03-APR-2016
Known Affected Releases:
15.0(2)SE2
Known Fixed Releases: *
15.0(2)SE5, 15.0(2)SE6, 15.2(1)E, 15.2(1)E1, 15.2(1)E2, 15.2(1)E3, 15.2(1)EY, 15.2(1.1)EY, 15.2(1.30)PSR, 15.2(2)E
Alert Type:
Updated *
Bug Id:
CSCur43620
Title:
%PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91
Status:
Fixed
Severity:
2 Severe
Description:

Release-Note

Symptom:
Description:
===========
Below traceback continuously thrown on5 member 3750x stack with 2 C3KX-NM-10G uplink module connected.

%PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 (3750X-4)
-Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 2FD87FCz 2FD87DCz 2FD682Cz (3750X-4)
%PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91
-Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 2C05AA8z 2C05A84z 2AF36BCz 2A90C04z 2FDC720z 2FD8AA0z
%PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 (3750X-4)
-Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 32006F0z 2B5DDD0z 2FDC720z 2FD8AA0z (3750X-4

Conditions:
Continuous message is shown when C3KX-NM-10G module is connected to 3750X stack.

Workaround:
Remove the C3KX-NM-10G uplink module.

Further Problem Description:

Last Modified:
19-APR-2016
Known Affected Releases:
15.2(2.4.61)E1
Known Fixed Releases: *
15.2(2)E, 15.2(2)E1, 15.2(2)E2, 15.2(2a)E1, 15.2(2b)E, 15.2(3)E, 15.2(3)E1, 15.2(3.1)BSR, 15.2(4)E, 15.2(4.0)ST
Alert Type:
New
Bug Id:
CSCuz24069
Title:
ping loss when HSRP status change from Init to Active
Status:
Open
Severity:
2 Severe
Description:

Symptom:
ping loss when HSRP status change from Init to Active

Conditions:
Observed at 3750X, 12.2(55)SE10 and 15.2(4)E1

Workaround:
None at now

Further Problem Description:

Last Modified:
26-APR-2016
Known Affected Releases:
15.2(4)E1
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuu55421
Title:
Error - The FRULink 10G Service Module (C3KX-SM-10G) is not responding
Status:
Fixed
Severity:
2 Severe
Description:

Symptom:
%PLATFORM_SM10G-3-NO_RESPONSE: The FRULink 10G Service Module (C3KX-SM-10G) is not responding.

Seen in the log after service policy is applied to a VLAN carried on an interface on the SM

Conditions:
C3KX-SM-10G installed in a 3750X

Switch#sh switch service-module
Switch/Stack supports service module CPU version: 03.00.78
Temperature CPU
Switch# H/W Status (CPU/FPGA) CPU Link Version
-----------------------------------------------------------------
2 OK 67C/63C notconnected 03.00.78

Workaround:
None

Further Problem Description:

Last Modified:
02-APR-2016
Known Affected Releases:
15.0(2)SE6
Known Fixed Releases: *
15.0(2)SE9, 15.2(2)E4, 15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.1.25)EA1, 15.2(4.2.1)EA2, 15.2(5.0.66)E, 15.2(5.5.36)E, 15.2(5.5.46)E
Alert Type:
Updated *
Bug Id:
CSCum17035
Title:
link on member switch goes down when master switchover
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
link on member switch goes down when master switchover

Conditions:
This issue happens when "no physleep enable" is configured on interface of member switch

Workaround:
remove "no physleep enable " command

Further Problem Description:

Last Modified:
03-APR-2016
Known Affected Releases:
15.0(2)SE5
Known Fixed Releases: *
15.0(2)SE6, 15.2(1.30)PSR, 15.2(2)E, 15.2(2b)E, 15.2(4.0)ST, 15.2(4.0.64a)E, 15.2(5.0)ST, 15.2(5.1.57i)E, 3.6(0)E
Alert Type:
Updated *
Bug Id:
CSCui21748
Title:
WS-C3750X-12S with "Copper SFP" causes FRNTEND_CTRLR-2-SUB_INACTIVE
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
MR2310.09.02-3700-3#show clock
*23:14:08.933 UTC Wed Mar 3 1993

MR2310.09.02-3700-3 uptime is 2 days, 23 hours, 14 minutes
System returned to ROM by power-on
System image file is "flash:c3750e-universalk9-mz.122-55.SE7"

000038: *Mar 1 03:23:20: FRNTEND_CTRLR-2-SUB_INACTIVE The front end controller 0 is inactive
-Traceback= 1D3CB2C 1D3D034 1F123A8 1F08E20
000015: *Mar 2 13:32:47: FRNTEND_CTRLR-2-SUB_INACTIVE The front end controller 0 is inactive (MR2310.09.02-3700-3-2)
-Traceback= 1D3CB2C 1D3D034 1F123A8 1F08E20 (MR2310.09.02-3700-3-2)

MR2310.09.02-3700-3#show platform front sub 0
State UNREACHABLE
Last Reset Reason UNKNOWN REASON

Conditions:
Issue observed after configuration has been applied to the port. Logging messages were not present with default port configuration.

Example configuration applied:

interface GigabitEthernet2/0/1
switchport mode access
small-frame violation-rate 100
storm-control broadcast level pps 5k 4.5k
storm-control multicast level pps 10k 9.5k
storm-control action shutdown
spanning-tree link-type point-to-point
end

FRNTEND_CTRLR-2-SUB_INACTIVE and traceback followed few hours after applying config.

Reloading box with applied configuration will yield trackback usually within few hours.

Workaround:
None.
Error messages and trackebacks do not seem to be service impacting still it's causing concern among customers.

"FRNTEND_CTRLR-2-SUB_INACTIVE" relates to PoE component on 3750X platform, WS-C3750X-12S doesn't support PoE.

Further Problem Description:

Last Modified:
04-APR-2016
Known Affected Releases:
12.2(55)SE6, 12.2(55)SE8, 12.2(58)SE2
Known Fixed Releases: *
15.0(2)SE6, 15.2(1.1)PSR, 15.2(2)E, 15.2(2b)E, 15.2(4.0)ST, 15.2(4.0.64a)E
Alert Type:
Updated *
Bug Id:
CSCuh34203
Title:
Receive Flowcontrol cannot to be operational on Portchannel of 10G port
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
If 10G port participate in portchannel,
Receive Flowcontrol cannot to be operational.

Conditions:
3750X with C3KX-NM-10G or C3KX-SM-10G.

Workaround:
unknown

Further Problem Description:

Last Modified:
03-APR-2016
Known Affected Releases:
15.0(2)SE1
Known Fixed Releases: *
15.0(2)SE5, 15.0(2)SE6, 15.2(1)E, 15.2(1)E1, 15.2(1)E2, 15.2(1)E3, 15.2(1)EY, 15.2(1.1)EY, 15.2(1.30)PSR, 15.2(2)E
Alert Type:
New
Bug Id:
CSCuz28436
Title:
Incorrect Status for "SYST" LED on removal of Fan
Status:
Open
Severity:
3 Moderate
Description:

Symptom:
when remove one FAN of two, "SYST" LED shows green

Conditions:
when remove one FAN

Workaround:
none

Further Problem Description:

Last Modified:
21-APR-2016
Known Affected Releases:
15.3(1)IE101.126
Known Fixed Releases:
Alert Type:
Updated *
Bug Id:
CSCuw71809
Title:
There is no warning message when the C3K configures "ip tcp adjust-mss"
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
There is no warning message when the C3K configures "ip tcp adjust-mss"

Conditions:
"ip tcp adjust-mss" command doesn't support on C3K Series

Workaround:
None

Further Problem Description:

Last Modified:
01-APR-2016
Known Affected Releases:
12.2(55)SE9, 15.0(2)SE6, 15.2(1)EX0.994, 15.2(2)E3, 15.2(3)E
Known Fixed Releases: *
15.2(2)E4, 15.2(3)E3, 15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.0.95a)E, 15.2(4.1.25)EA1, 15.2(4.1.5a)E, 15.2(5.0.39)E, 15.2(5.5.36)E
Alert Type:
Updated *
Bug Id:
CSCux31188
Title:
Shutdown is displayed with linkup channel member port on show run.
Status:
Fixed
Severity:
3 Moderate
Description:

Symptom:
Shutdown command is displayed on channel member port.
However, channel member port is linkup status.
This issue is seen after shut/no shut on channel port.

Conditions:
3750X
Ether-Channel connection.

Workaround:
'no shutdown' command on channel member port.

Further Problem Description:

Last Modified:
01-APR-2016
Known Affected Releases:
15.0(2)SE6
Known Fixed Releases: *
15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.1.25)EA1, 15.2(5.0.71)E, 15.2(5.5.36)E, 15.2(5.5.46)E, 15.2(5.5.64)E, 15.2(5.6.1)E, 3.8(1)E
Alert Type:
Updated *
Bug Id:
CSCuy17257
Title:
HFL PDU counter issue when link failure happens in rep segment
Status:
Open
Severity: *
4 Minor
Description:

Symptom:
when link failure happens in REP segment, saw HFL PDU sent out from link failure interfaces, also saw Rx/Tx HFL PDU counters mismacth on each interfaces from [show interface xxx rep detail] command.

Conditions:
removed the cables or link failure occurs in rep segment

Workaround:
rep segment convergence is ok

Further Problem Description:

Last Modified:
21-APR-2016
Known Affected Releases:
15.2(4)E
Known Fixed Releases:

Find additional information in Bug Search index.

 

2015 Cisco and/or its affiliates. All rights reserved. Terms & Conditions | Privacy Statement | Cookie Policy | Trademarks

 

没有评论: