Alert Type: | Updated * |
Bug Id: | CSCuh97014 | Title: | C3KX-SM-10G: remote port CTS link down after 3750X master reload |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: If we reload 3750X/3560X stack Master , CTS link configured on CK3X-SM-10G port on member switch goes down (which was UP before the master reload)
Conditions: 3750X/3560X stack of atleast 3 switches , wherein a Master Switch, alternate-Master ( i.e switch with next highets priority) and a member switch with CK3X-SM-10G module. On the Member Switch , CTS is configured on CK3X-SM-10G port(s)
If we reload Master, alternate Master will be become new Master. After this, CTS link configured on one of the ports of CK3X-SM-10G installed on Member Switch goes down.
Workaround:
The CTS link can be restored (i.e brought UP) by doing a shut/no shut on the ports on the SM module |
|
Last Modified: | 03-APR-2016 |
|
Known Affected Releases: | 15.0(2)SE2 |
|
Known Fixed Releases: * | 15.0(2)SE5, 15.0(2)SE6, 15.2(1)E, 15.2(1)E1, 15.2(1)E2, 15.2(1)E3, 15.2(1)EY, 15.2(1.1)EY, 15.2(1.30)PSR, 15.2(2)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCur43620 | Title: | %PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Release-Note
Symptom: Description: =========== Below traceback continuously thrown on5 member 3750x stack with 2 C3KX-NM-10G uplink module connected.
%PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 (3750X-4) -Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 2FD87FCz 2FD87DCz 2FD682Cz (3750X-4) %PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 -Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 2C05AA8z 2C05A84z 2AF36BCz 2A90C04z 2FDC720z 2FD8AA0z %PLATFORM_IPC-3-COMMON: Unknown IPC message type 65535 size 91 (3750X-4) -Traceback= 65AE00z 2A74520z 2C44E6Cz 2C45B3Cz 2B40F94z 2B40F3Cz 2B46AE8z 2B46B84z 2B41044z 32006F0z 2B5DDD0z 2FDC720z 2FD8AA0z (3750X-4
Conditions: Continuous message is shown when C3KX-NM-10G module is connected to 3750X stack.
Workaround: Remove the C3KX-NM-10G uplink module.
Further Problem Description:
|
|
Last Modified: | 19-APR-2016 |
|
Known Affected Releases: | 15.2(2.4.61)E1 |
|
Known Fixed Releases: * | 15.2(2)E, 15.2(2)E1, 15.2(2)E2, 15.2(2a)E1, 15.2(2b)E, 15.2(3)E, 15.2(3)E1, 15.2(3.1)BSR, 15.2(4)E, 15.2(4.0)ST |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz24069 | Title: | ping loss when HSRP status change from Init to Active |
|
Status: | Open |
|
Severity: | 2 Severe |
Description: | Symptom: ping loss when HSRP status change from Init to Active
Conditions: Observed at 3750X, 12.2(55)SE10 and 15.2(4)E1
Workaround: None at now
Further Problem Description:
|
|
Last Modified: | 26-APR-2016 |
|
Known Affected Releases: | 15.2(4)E1 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuu55421 | Title: | Error - The FRULink 10G Service Module (C3KX-SM-10G) is not responding |
|
Status: | Fixed |
|
Severity: | 2 Severe |
Description: | Symptom: %PLATFORM_SM10G-3-NO_RESPONSE: The FRULink 10G Service Module (C3KX-SM-10G) is not responding.
Seen in the log after service policy is applied to a VLAN carried on an interface on the SM
Conditions: C3KX-SM-10G installed in a 3750X
Switch#sh switch service-module Switch/Stack supports service module CPU version: 03.00.78 Temperature CPU Switch# H/W Status (CPU/FPGA) CPU Link Version ----------------------------------------------------------------- 2 OK 67C/63C notconnected 03.00.78
Workaround: None
Further Problem Description:
|
|
Last Modified: | 02-APR-2016 |
|
Known Affected Releases: | 15.0(2)SE6 |
|
Known Fixed Releases: * | 15.0(2)SE9, 15.2(2)E4, 15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.1.25)EA1, 15.2(4.2.1)EA2, 15.2(5.0.66)E, 15.2(5.5.36)E, 15.2(5.5.46)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCum17035 | Title: | link on member switch goes down when master switchover |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: link on member switch goes down when master switchover
Conditions: This issue happens when "no physleep enable" is configured on interface of member switch
Workaround: remove "no physleep enable " command
Further Problem Description:
|
|
Last Modified: | 03-APR-2016 |
|
Known Affected Releases: | 15.0(2)SE5 |
|
Known Fixed Releases: * | 15.0(2)SE6, 15.2(1.30)PSR, 15.2(2)E, 15.2(2b)E, 15.2(4.0)ST, 15.2(4.0.64a)E, 15.2(5.0)ST, 15.2(5.1.57i)E, 3.6(0)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCui21748 | Title: | WS-C3750X-12S with "Copper SFP" causes FRNTEND_CTRLR-2-SUB_INACTIVE |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: MR2310.09.02-3700-3#show clock *23:14:08.933 UTC Wed Mar 3 1993
MR2310.09.02-3700-3 uptime is 2 days, 23 hours, 14 minutes System returned to ROM by power-on System image file is "flash:c3750e-universalk9-mz.122-55.SE7"
000038: *Mar 1 03:23:20: FRNTEND_CTRLR-2-SUB_INACTIVE The front end controller 0 is inactive -Traceback= 1D3CB2C 1D3D034 1F123A8 1F08E20 000015: *Mar 2 13:32:47: FRNTEND_CTRLR-2-SUB_INACTIVE The front end controller 0 is inactive (MR2310.09.02-3700-3-2) -Traceback= 1D3CB2C 1D3D034 1F123A8 1F08E20 (MR2310.09.02-3700-3-2)
MR2310.09.02-3700-3#show platform front sub 0 State UNREACHABLE Last Reset Reason UNKNOWN REASON
Conditions: Issue observed after configuration has been applied to the port. Logging messages were not present with default port configuration.
Example configuration applied:
interface GigabitEthernet2/0/1 switchport mode access small-frame violation-rate 100 storm-control broadcast level pps 5k 4.5k storm-control multicast level pps 10k 9.5k storm-control action shutdown spanning-tree link-type point-to-point end
FRNTEND_CTRLR-2-SUB_INACTIVE and traceback followed few hours after applying config.
Reloading box with applied configuration will yield trackback usually within few hours.
Workaround: None. Error messages and trackebacks do not seem to be service impacting still it's causing concern among customers.
"FRNTEND_CTRLR-2-SUB_INACTIVE" relates to PoE component on 3750X platform, WS-C3750X-12S doesn't support PoE.
Further Problem Description:
|
|
Last Modified: | 04-APR-2016 |
|
Known Affected Releases: | 12.2(55)SE6, 12.2(55)SE8, 12.2(58)SE2 |
|
Known Fixed Releases: * | 15.0(2)SE6, 15.2(1.1)PSR, 15.2(2)E, 15.2(2b)E, 15.2(4.0)ST, 15.2(4.0.64a)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuh34203 | Title: | Receive Flowcontrol cannot to be operational on Portchannel of 10G port |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: If 10G port participate in portchannel, Receive Flowcontrol cannot to be operational.
Conditions: 3750X with C3KX-NM-10G or C3KX-SM-10G.
Workaround: unknown
Further Problem Description:
|
|
Last Modified: | 03-APR-2016 |
|
Known Affected Releases: | 15.0(2)SE1 |
|
Known Fixed Releases: * | 15.0(2)SE5, 15.0(2)SE6, 15.2(1)E, 15.2(1)E1, 15.2(1)E2, 15.2(1)E3, 15.2(1)EY, 15.2(1.1)EY, 15.2(1.30)PSR, 15.2(2)E |
|
|
| |
| |
|
Alert Type: | New |
Bug Id: | CSCuz28436 | Title: | Incorrect Status for "SYST" LED on removal of Fan |
|
Status: | Open |
|
Severity: | 3 Moderate |
Description: | Symptom: when remove one FAN of two, "SYST" LED shows green
Conditions: when remove one FAN
Workaround: none
Further Problem Description:
|
|
Last Modified: | 21-APR-2016 |
|
Known Affected Releases: | 15.3(1)IE101.126 |
|
Known Fixed Releases: | |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuw71809 | Title: | There is no warning message when the C3K configures "ip tcp adjust-mss" |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: There is no warning message when the C3K configures "ip tcp adjust-mss"
Conditions: "ip tcp adjust-mss" command doesn't support on C3K Series
Workaround: None
Further Problem Description:
|
|
Last Modified: | 01-APR-2016 |
|
Known Affected Releases: | 12.2(55)SE9, 15.0(2)SE6, 15.2(1)EX0.994, 15.2(2)E3, 15.2(3)E |
|
Known Fixed Releases: * | 15.2(2)E4, 15.2(3)E3, 15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.0.95a)E, 15.2(4.1.25)EA1, 15.2(4.1.5a)E, 15.2(5.0.39)E, 15.2(5.5.36)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCux31188 | Title: | Shutdown is displayed with linkup channel member port on show run. |
|
Status: | Fixed |
|
Severity: | 3 Moderate |
Description: | Symptom: Shutdown command is displayed on channel member port. However, channel member port is linkup status. This issue is seen after shut/no shut on channel port.
Conditions: 3750X Ether-Channel connection.
Workaround: 'no shutdown' command on channel member port.
Further Problem Description:
|
|
Last Modified: | 01-APR-2016 |
|
Known Affected Releases: | 15.0(2)SE6 |
|
Known Fixed Releases: * | 15.2(4)E1, 15.2(4)EA1, 15.2(4.0.95)EA1, 15.2(4.1.25)EA1, 15.2(5.0.71)E, 15.2(5.5.36)E, 15.2(5.5.46)E, 15.2(5.5.64)E, 15.2(5.6.1)E, 3.8(1)E |
|
|
| |
| |
|
Alert Type: | Updated * |
Bug Id: | CSCuy17257 | Title: | HFL PDU counter issue when link failure happens in rep segment |
|
Status: | Open |
|
Severity: * | 4 Minor |
Description: | Symptom: when link failure happens in REP segment, saw HFL PDU sent out from link failure interfaces, also saw Rx/Tx HFL PDU counters mismacth on each interfaces from [show interface xxx rep detail] command.
Conditions: removed the cables or link failure occurs in rep segment
Workaround: rep segment convergence is ok
Further Problem Description:
|
|
Last Modified: | 21-APR-2016 |
|
Known Affected Releases: | 15.2(4)E |
|
Known Fixed Releases: | |
|
|
| |
没有评论: